Key equations and principles
Frequently asked questions (FAQ)
What is the stability criterion for a laser resonator?
For the round-trip ABCD matrix M=[[A,B],[C,D]], let Tr=A+D be the trace. The cavity is stable when |Tr/2|<1; |Tr/2|=1 is a marginal (boundary) state, where the beam diverges or degrades along the cavity axis; when |Tr/2|>1 the cavity is unstable, the spot keeps growing and no stable resonance can form.
What is the relationship between the g parameter criterion and the trace criterion?
For a two-mirror linear cavity, define g₁=1−L/R₁ and g₂=1−L/R₂, then Tr/2 = 2g₁g₂−1. Therefore the stability criterion |Tr/2|<1 is equivalent to 0<g₁g₂<1. The two are fully equivalent, and the g parameter form is more intuitive when assessing stability regions.
Why are confocal and concentric cavities both in a marginal state?
For a confocal cavity R₁=R₂=L, g₁=g₂=0 and g₁g₂=0; for a concentric cavity R₁=R₂=L/2, g₁=g₂=−1 and g₁g₂=1. The two fall on the boundaries 0 and 1 of the criterion respectively, so both are marginal. A truly stable cavity requires strict 0<g₁g₂<1.
Where is the beam waist in a confocal cavity?
For a confocal cavity with R₁=R₂=L, the foci of the two mirrors coincide at the centre of the cavity, the beam waist lies at the midpoint, z_R=L/2 and the single-pass Gouy phase is 90°. This is a typical degenerate cavity, in which the longitudinal mode spacings overlap.
How do I enter a plane mirror? Can the radius of curvature be negative?
Entering 0 in the radius of curvature field denotes a plane mirror (equivalent to R=∞, with the matrix reducing to the identity matrix, giving no angular deflection). A concave mirror takes a positive R and a convex mirror a negative R (equivalent to a diverging mirror); both affect the stability criterion.
How do I read the stability region plot?
The horizontal axis is g₁ and the vertical axis g₂; the stable region is the band satisfying 0<g₁g₂<1 (the area between the two hyperbolas). The red point marks the current input (g₁,g₂), the blue point is the confocal cavity (0,0), the green point the plane-parallel cavity (1,1) and the orange point the concentric cavity (−1,−1) (which shares the g₁g₂=1 boundary with the plane-parallel cavity but lies in the third quadrant). If the red point falls outside the region, the cavity is unstable.
How do I read the intracavity spot evolution curve?
The horizontal axis is the coordinate z along the optical axis and the vertical axis the spot radius w. The two ends are the mirror positions, the lowest point in the middle is the beam waist; the heights at the two mirrors are the mirror spot radii, which directly relate to the mirror damage threshold and output coupling design.
How is a ring cavity calculated?
Switch to ‘Custom round-trip matrix’ and arrange the elements of one loop in optical path order (free space, spherical mirror, lens). The tool multiplies them in sequence to obtain the round-trip matrix and assesses stability using the same trace criterion, also giving FSR=c/L_rt.
What is the practical use of the Gouy phase?
The Gouy phase is the additional phase advance of a resonator relative to the geometric cavity; it shifts transverse mode frequencies away from degenerate values: the spacing of adjacent transverse modes is determined by arccos(√(g₁g₂)). When the single-pass Gouy phase of a confocal cavity is 90°, longitudinal mode frequencies become degenerate, making it a Gaussian cavity type commonly used in pulsed lasers.
How sensitive is stability to cavity length errors?
The closer to the criterion boundary (such as g₁g₂→0 or →1), the more easily a small deviation in cavity length or radius of curvature pushes the cavity out of the stable region. In practice the operating point is therefore designed in the middle region of 0<g₁g₂<1 (e.g. 0.3~0.7), which is least sensitive to machining and alignment errors.
How is the FSR of a two-mirror linear cavity calculated?
In a two-mirror linear cavity the optical path travelled in one round trip is 2L, so the longitudinal mode spacing FSR=c/(2L). For a ring cavity it is calculated from the geometric length of one loop. This tool distinguishes the two automatically and gives the corresponding result.
What are the unit conventions for the calculated results?
The wavelength λ is in nm, lengths (L, R, z_R, w₀) in mm and the spot radius is displayed in µm; internally the tool converts everything to mm for calculation to avoid unit confusion.