QQ: 859818709

LINOS F-Theta-Ronar 4401-616-000-26 Telecentric Field Lens, 532 nm, f=250.1 mm, Fused Silica

LINOS F-Theta-Ronar 4401-616-000-26 Telecentric Field Lens, 532 nm, f=250.1 mm, Fused Silica

Price on request
Category:

Description

Product Overview

The LINOS 4401-616-000-26 is a green-wavelength telecentric F-Theta field lens from the F-Theta-Ronar series of Excelitas Technologies (Qioptiq), Germany. It is designed for 532 nm, has an effective focal length of 250.1 mm and uses fused silica optics. The scan field is 69 × 69 mm, the focused spot diameter is about 17 µm with a 14.0 mm input beam, and total transmittance over the working band is greater than 96. It is a core scan objective for laser marking, welding and precision micro-machining systems.

Key Features

  • Telecentric optical design: the chief ray strikes the workpiece perpendicularly across the whole field, so drilled side walls show no taper and edge quality matches the centre — ideal for deep engraving, precision cutting and drilling.
  • Optimized for the green band: design wavelength 532 nm, total transmittance over the working band greater than 96.
  • High damage threshold coating: coating LIDT 20 J/cm², stable under high power over long operating periods.
  • Fused silica body: low thermal expansion and low absorption suppress thermal lensing; the low-absorption coating further reduces coating heating.
  • Suited to ultrashort pulses: group delay dispersion is only 5132 fs², so picosecond and femtosecond processing is free of pulse broadening concerns.
  • Replaceable protective window as standard: protective window PG 4401-517-006-00 isolates dust and spatter, protects the internal optics and keeps maintenance cost low.

Technical Specifications

Parameter Specification
Model 4401-616-000-26
Type LINOS F-Theta-Ronar telecentric F-Theta field lens (low absorption)
Brand LINOS / Excelitas Technologies (Qioptiq, Germany)
Design wavelength 532 nm
Effective focal length (EFL) 250.1 mm
Back focal length (BFL) 377.3 mm
Working distance (WD) 374.6 mm
Flange focal length (FFL) 539.8 mm
Maximum input beam diameter (1/e²) 14.0 mm
Recommended galvo spacing m1 17.0 mm
Recommended galvo spacing m2 40.0 mm
Recommended galvo spacing m2 (mechanical) 36.8 mm
Scan angle ±θ 8.0 °
Scan field 69 x 69 mm
Focused spot diameter 17 μm
Maximum telecentric error 0.4 °
Total transmittance over working band Greater than 96
Group delay dispersion (GDD) 5132 fs²
Coating LIDT 20 J/cm²
Back-reflection focus position (from first surface) 3210 mm
Weight 3210 g
Protective window part number 4401-517-006-00

Applications

  • Laser marking and engraving: a 69 × 69 mm field with an approximately 17 µm spot gives clean marking edges on metals, plastics and coatings, with high fidelity for small characters and 2D codes.
  • Precision laser welding: the 250.1 mm effective focal length gives a moderate depth of focus, so galvo welding of battery housings and precision hardware produces consistent seams.
  • Cutting and drilling: the telecentric layout leaves deep-hole side walls almost taper-free, and thick-material cut edges stay vertical.
  • Micro-machining and research: with 5132 fs² group delay dispersion, ultrafast micro-machining pulses are not broadened and spot energy stays concentrated.

Installation and selection notes: field lens performance depends on correct installation. First enter the recommended galvo spacings m1 = 17.0 mm and m2 = 40.0 mm into the scan head software, then set the distance from the field lens reference plane to the workpiece according to the flange focal length of 539.8 mm, and finally fine-tune the Z axis for the smallest spot before production. Keep the protective window PG 4401-517-006-00 fitted and check it for contamination regularly, because contamination directly degrades the spot energy distribution. For other field sizes, scale from other focal lengths in the same series (this model, f = 250 mm, gives a 69 × 69 mm field).

FAQ

Which lasers suit the 4401-616-000-26?

It is designed for 532 nm (see the parameter table for the working band) and suits nanosecond, picosecond and femtosecond industrial lasers in that band. The coating damage threshold is 20 J/cm²; please confirm against your pulse width and power when selecting.

What scan field and spot size does the 4401-616-000-26 give?

With a 14.0 mm input beam the scan field is 69 × 69 mm (scan angle ±8.0°) and the focused spot diameter is about 17 µm. A larger entrance pupil or another focal length in the series gives a different field and spot combination.

What are the advantages of a telecentric field lens over a standard F-Theta lens?

The telecentric design keeps the chief ray close to perpendicular to the workpiece across the field (maximum telecentric error 0.4° for this model), so deep holes and thick-material cuts show no side-wall taper and the focus does not drift with position — well suited to precision work with strict perpendicularity requirements.

Reviews

There are no reviews yet.

Be the first to review “LINOS F-Theta-Ronar 4401-616-000-26 Telecentric Field Lens, 532 nm, f=250.1 mm, Fused Silica”

Your email address will not be published. Required fields are marked *

中文EN