QQ: 859818709

Thorlabs PF125B-P5 Clamping Fork for Ø1.85 in Pedestal Bases, 1.25 in Slot, 5-Piece Pack

Thorlabs PF125B-P5 Clamping Fork for Ø1.85 in Pedestal Bases, 1.25 in Slot, 5-Piece Pack

Price on request
Category:

Description

Product Overview

This is the 5-piece pack of the PF125B; each fork is identical to the single-unit version.

A clamping fork is the small part that turns a pedestal base into a rigid, repeatable mount. The base sits flat on the table, an optical post or mirror mount is threaded into the base, and the fork straddles the base flange and pulls it down with one cap screw. The fork never touches the post. It presses only on the flange, and because the underside of the fork is relieved, the actual contact against the table is reduced to three points. Those three points define a plane, which is why the assembly stays stable even on a table whose surface is not perfectly flat after years of use.

The PF125B is the middle of the three fork lengths that Thorlabs offers for Ø1.85 in (Ø47.0 mm) pedestal bases. Its counterbored slot measures 1.25 in (31.8 mm). The short version, PF85B, gives 0.85 in (21.6 mm); the long version, PF175B, gives 2.12 in (53.8 mm). Slot length is essentially the only thing that separates the three: the body, the screw size and the clamping geometry are shared across the family. That is convenient in one respect, because a lab can standardise on one screw and one tightening habit, and awkward in another, because the three parts look almost identical in a parts drawer.

The body is stainless steel rather than anodised aluminium. Three consequences follow. The slot does not gall or deform after hundreds of tighten-and-loosen cycles, which matters on a bench where mounts are re-aimed daily. The fork can be used at the entrance of a vacuum chamber or inside a cleanroom enclosure without becoming a source of soft-metal debris. And because stainless is harder than the anodised aluminium of a base, the base takes the wear and the fork keeps its geometry.

When the cap screw is loosened, the fork rotates through a full 360 degrees about the screw axis. The installer can therefore place and align the base first, confirm the beam height and the pointing, and only then swing the fork round to a direction that clears neighbouring mounts, cables or a translation stage. Tightening the screw fixes the clamp force and the angular position at the same moment, so there is no separate locking step that can be forgotten.

Thorlabs names the PB4(/M) and PB4R(/M) base adapters as the recommended companions for this fork. The fork will also sit on Ø1 in post holders and on the BLP01 base clamp, but the PB4 family is the pairing the mechanical drawings were dimensioned around. If a base of a different family is already bolted to the table, check the flange diameter and the slot clearance before ordering a pack, because the fork is sized for a Ø1.85 in flange, not for a generic 1.85 in footprint.

Key Features

  • Five identical forks per pack. All five are the 1.25 in slot version. The pack is not a mixed assortment, so a drawer cannot silently acquire the wrong slot length.
  • Stainless steel body. Resists slot wear, thread galling and the soft-metal shedding that anodised aluminium parts show after repeated clamping.
  • Three-point contact against the table. The relieved underside means the fork bears on three small areas rather than a full ring, so clamp force is predictable and the base does not rock.
  • 1.25 in (31.8 mm) counterbored slot. The middle tier: enough travel to capture a base that is a few millimetres off its nominal position, without the footprint penalty of the 2.12 in version.
  • 1/4″-20 (M6) cap screw interface. The same screw family used across imperial and metric Thorlabs tables, so one wrench covers a whole build.
  • Full 360 degree rotation when loosened. Set the base position first, then choose the clamp direction last, which is the order that actually works on a crowded table.
  • Dimensioned for Ø1.85 in (Ø47.0 mm) pedestal bases. Matches the flange diameter of the PB4(/M) and PB4R(/M) adapters named by Thorlabs as the intended companions.
  • Consumable-grade spares. Five units is roughly the number a bench needs once bases are counted at 1.2 units each, which is the ratio this page recommends below.

Technical Specifications

Parameter Specification
Model PF125B-P5
Pack size 5 forks, all identical
Component type Clamping fork (also described as a clamping bar or base clamp)
Base compatibility Ø1.85 in (Ø47.0 mm) pedestal bases
Recommended base adapter PB4(/M) or PB4R(/M)
Slot length 1.25 in (31.8 mm)
Slot type Counterbored slot
Screw interface 1/4″-20 (M6) cap screw
Body material Stainless steel
Contact geometry Three-point contact with the table surface
Rotation when screw is loosened 360 degrees
Table compatibility Imperial 1/4″-20 and metric M6 optical tables and breadboards
Finish Bare stainless steel, no soft coating to wear through
Quantity per pack 5

Values above are the family specification published by Thorlabs for the PF125B fork. Slot length is the only parameter that changes between the three fork models; all other rows are shared.

Applications

Keeping a bench from stopping for a missing low-cost part. A fork is a consumable in practice even though nothing about it wears out quickly. It leaves the lab attached to a base that is shipped to another site, it disappears into a shared tool drawer, its thread picks up a burr after one careless cross-threading, and it is the first part a student pockets when a project is wound down. The cost of the part is trivial; the cost of discovering the shortage in the middle of an alignment session is not. A pack of five is a stocking decision rather than a pricing decision, and it is worth treating it that way.

Sizing the stock. The rule this page recommends is one fork per Ø1.85 in base, multiplied by 1.2. The 20 percent covers the fork that is currently in use on a temporary rig, the one that went out with a loaned base, and the one that will be dropped behind the optical table and never seen again. A bench with eight bases therefore wants ten forks, which is two packs. Buying to that number once is cheaper in engineering time than three separate single-unit orders placed in the week before a deadline.

Avoiding the mixed-slot failure. The three fork lengths are visually similar and differ only in how far the slot extends. A 1.25 in fork placed over a base that needs the 2.12 in version will still accept the screw, but the screw head lands on the shoulder of the counterbore instead of seating in it. The clamp then feels tight while applying almost no downward force, and the base creeps under the slightest side load. Keeping one slot length in one drawer, and buying in packs so that the drawer refills with the same length, removes this failure mode entirely.

Cleanroom and vacuum antechamber use. Stainless forks are the sensible choice where aluminium is not welcome. An anodised part that is clamped and unclamped repeatedly can shed coating flakes at the contact points; a stainless fork does not. The fork itself is not a vacuum component and is not intended for use inside a chamber, but it is a reasonable choice for the bench just outside the load lock, where parts migrate in and out and where particulate control already matters.

Teaching laboratories and shared benches. In a room where twenty people build the same interferometer in a semester, forks are the part that goes missing. A pack of five per station, recorded against the station number, keeps the kit complete and makes the end-of-term inventory a counting exercise rather than a procurement exercise.

Prototype rigs that get rebuilt weekly. Because the fork rotates freely once loosened, a rig can be re-laid-out without removing the bases. Loosen, swing the fork clear, move the base along the tapped hole grid, swing back and tighten. That sequence is the reason the part exists, and it is worth teaching to anyone who has been fighting a base that will not sit where the drawing says it should.

Selection Guide

Four decisions cover almost every case. Work through them in order, because the later ones depend on the earlier ones.

  • Step 1, confirm the base family. The fork is sized for a Ø1.85 in (Ø47.0 mm) pedestal base flange, which in the Thorlabs catalogue means the PB4(/M) and PB4R(/M) adapters. A Ø1 in post holder or a BLP01 will also accept the fork, but a base from another family with a different flange diameter will not seat correctly.
  • Step 2, choose the slot length. 0.85 in (21.6 mm) for compact assemblies where the base sits close to the nominal position and adjacent hardware leaves no room; 1.25 in (31.8 mm) as the default for general work; 2.12 in (53.8 mm) where bases are placed by eye, where the tapped hole grid forces an offset, or where the fork has to reach past a neighbouring component.
  • Step 3, choose pack or single. Count the Ø1.85 in bases on the bench, multiply by 1.2, and buy packs if the result is four or more. Below that, single units are easier to account for.
  • Step 4, confirm the screw. A 1/4″-20 cap screw on an imperial table, an M6 cap screw on a metric table. The counterbore is sized so that the head sits below the fork surface, which is why an over-long screw is more of a nuisance here than on a plain washer.

The reason 1.25 in is the sensible default deserves one paragraph. The 0.85 in version exists for dense assemblies: it keeps the fork footprint small when two bases sit 25 mm apart and there is simply no room for a longer bar. The 2.12 in version exists for the opposite problem, where the base cannot be placed where the drawing wants it because a tapped hole is already occupied, or where the fork must be rotated to an angle that puts the screw well off the base centre. Between those two extremes, 1.25 in captures a base that is a few millimetres off nominal, which is the situation in the great majority of builds, and it does so without the extra 22 mm of bar that the long version adds to the table footprint.

Series Comparison

Model Slot length Pack size Best suited to
PF85B 0.85 in (21.6 mm) Single Compact assemblies, bases close to nominal position, tight neighbours
PF85B-P5 0.85 in (21.6 mm) 5 forks Stocking a dense bench that uses the short slot throughout
PF125B 1.25 in (31.8 mm) Single One-off builds, first article to check a new base family
PF125B-P5 1.25 in (31.8 mm) 5 forks This page. General-purpose stocking for Ø1.85 in bases
PF175B 2.12 in (53.8 mm) Single Bases placed by eye, offset holes, forks reaching past hardware
PF175B-P5 2.12 in (53.8 mm) 5 forks Stocking a large table where long slots are used throughout

All six share the same stainless body, the same three-point contact geometry, the same 1/4″-20 (M6) cap screw and the same 360 degree rotation when loosened. A lab that standardises on one slot length also standardises on one screw, one wrench and one tightening torque, which is a real maintenance benefit rather than a marketing one.

FAQ

Q: Why does Thorlabs recommend the PB4(/M) or PB4R(/M) base adapter instead of a post series for this fork?

A: Because a fork clamps a flange, and a post does not have one. The PB4 family is a pedestal base: a flat, circular flange with a threaded centre, sitting directly on the table. The fork straddles that flange and pulls it down. A post, or a post holder, is a vertical tube with no flange at table level, so there is nothing for the fork to bear on; a post is held by a post holder that is itself bolted to the table. Using the fork with the base adapter it was dimensioned for is what produces the three-point contact the drawing assumes.

Q: Are the five forks in the pack different from each other?

A: No. All five are PF125B forks with a 1.25 in (31.8 mm) slot, the same stainless body and the same 1/4″-20 (M6) screw interface. The pack is not an assortment of slot lengths, and it should not be split into a drawer that already contains other lengths without labelling.

Q: How much torque should the cap screw receive?

A: Enough to stop the base from moving under a light push, and no more. Thorlabs warns explicitly that significant over-tightening will deform the surface of the optical table, and that the resulting damage causes components to misalign and stability to degrade. A table surface that has been dimpled by a fork does not recover. Tighten by feel with a short wrench, check that the base cannot be rotated by hand, and stop.

Q: Will the fork damage the anodised surface of my breadboard?

A: Three-point contact concentrates the load into three small areas, so a heavily over-tightened fork can leave three shallow marks rather than one broad one. Correctly tightened, the marks are not visible. On a breadboard that will be re-used for years, the practical protection is discipline at the wrench rather than a soft washer, which would defeat the point of the three-point geometry.

Q: Can the same fork be used on an M6 table?

A: Yes. The 1/4″-20 (M6) designation means the fork accepts either screw, so the same part works on an imperial table with a 1/4″-20 cap screw and on a metric table with an M6 cap screw. What changes is the screw, not the fork.

Q: Does the fork work with Ø1 in post holders?

A: It will fit, and Thorlabs lists Ø1 in post holders and the BLP01 base clamp among the parts the fork can be used with. The recommended pairing remains the PB4 family, because that is the combination whose flange diameter, slot clearance and stack height were designed together. If a post holder is used, check that the fork does not foul the holder body when it is rotated.

Q: How many forks should a bench keep in stock?

A: One per Ø1.85 in base, multiplied by 1.2, rounded up. The extra 20 percent covers the fork in temporary use, the one that left with a loaned base and the one that will eventually be lost. For a bench with eight bases that means ten forks, or two packs.

Q: What is the difference between the counterbored slot and a plain slot?

A: The counterbore is a recessed step at the top of the slot. The screw head sits down inside it, below the fork surface, so the head does not stand proud where it could catch a cable or foul a neighbouring component. It also means the clamping force is applied through the shoulder of the recess, which is why a fork used with the wrong slot length can feel tight while applying very little downward load.

Usage Precautions

  • Do not over-tighten. Thorlabs states that significantly over-tightening the cap screw will deform the optical table surface, causing the mounted components to become misaligned and reducing stability. The deformation is permanent. A short wrench and a light hand are the correct tools.
  • Seat the screw head in the counterbore. If the head sits on the shoulder rather than dropping into the recess, the slot length does not match the base position. Move the base, or change to the correct fork length, rather than forcing the screw.
  • Keep slot lengths separated. Store the 1.25 in forks apart from the 0.85 in and 2.12 in versions. The three are close enough in appearance that a mixed drawer will eventually produce a mis-clamped base.
  • Check the thread before installation. A stainless screw thread that has picked up a burr will gall the fork thread the first time it is run in. Run the screw in by hand before applying a wrench.
  • Clean with a solvent, not an abrasive. Isopropyl alcohol and a lint-free wipe are sufficient. Abrasive pads will round the counterbore shoulder and change the clamp geometry.
  • Do not use the fork as a general clamp. It is dimensioned for a Ø1.85 in pedestal base flange. Using it to hold a plate, a filter holder or a custom bracket puts the load somewhere the three-point geometry was not designed for.
  • Inspect after a dropped part. A fork that has fallen onto a concrete floor may have a slightly bent ear. A bent fork will clamp at an angle, and the base will creep. Compare it against a known-good fork before putting it back into service.

Disclaimer

The mechanical data on this page is taken from the manufacturer published specification for the PF125B family and is provided to help with selection. Dimensional drawings, tolerances and finish callouts on the current datasheet take precedence over this summary, and specifications may change without notice. This page does not restate any price; pricing, lead time and availability are confirmed at the time of quotation. Where a project depends on the exact stack height of a base plus fork assembly, obtain the current drawing before committing the mechanical design.

Contact Us

For help matching a fork length to an existing base, for a quantity quotation on multiple packs, or for a check against a mechanical drawing, contact the sales team and include the base model, the table thread and the number of bases on the bench. Orders placed before mid-afternoon on a working day are normally released the same day when the item is in local stock; items held in an overseas warehouse are quoted with a realistic transit window rather than a best case.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PF125B-P5 Clamping Fork for Ø1.85 in Pedestal Bases, 1.25 in Slot, 5-Piece Pack”

Your email address will not be published. Required fields are marked *

中文EN