Description
Product Overview
PF85B is a clamping fork for pedestal bases with a flange diameter of 1.85 in (47.0 mm). The fork straddles the base flange, a single 1/4 in-20 or M6 cap screw pulls it down onto the optical table, and the counterbored slot through which that screw passes is 0.85 in (21.6 mm) long. The body is stainless steel. The design is described by Thorlabs as universal, which in this context means the fork will sit on an imperial or a metric table and will accept either thread without a separate part number.
The mechanical idea is worth stating carefully, because it is the whole reason the part exists and it is invisible in a photograph. These clamping forks create three points of contact with the table. Three points, not a ring and not a line. The underside of the fork is relieved so that the metal bears on three small areas around the base flange rather than on a continuous annulus. Three points define a plane uniquely and without over-constraint, which is why the assembly does not rock, does not fight itself, and repeats its position when it is loosened and re-tightened. A four-point support on a surface that is flat to a few micrometres but not perfectly flat will rock between diagonal pairs; a three-point support cannot.
The second half of the design is rotation. Once the cap screw is loosened, each fork can swivel around the pedestal-style post holder or post to access the most convenient mounting holes on the optical table or breadboard. This is not a convenience feature bolted on at the end. It is the same design intention seen from the other side: the fork has to be rigid in the direction that clamps and free in the direction that lets the user find a hole. A part that could only clamp along a fixed radius would force the base position to be chosen to suit the fork, rather than the fork being chosen to suit the base.
What the fork does not do is hold a post on its own. The intended chain is a Ø1.5 in post threaded into a pedestal base adapter, the base sitting flat on the table, and the fork clamping the base flange. Thorlabs names PB4(/M) and PB4R(/M) as the companions for this fork: solid 303 stainless adapters with a 1.85 in (47.0 mm) outside diameter and a 1/4 in-20 or M6 threaded stud, which convert the bottom of a Ø1.5 in post into a pedestal-style mount. PB4 tightens with a 1/8 in (3 mm) hex key. PB4R has a 3/16 in (5 mm) hex socket and four strong magnets in its underside, so the base can be located by magnet before any clamp is applied.
A fork is also not the only way to use a pedestal base. It can be paired directly with a Ø1 in post holder, or with a BLP01 adjustable-height post, and in those arrangements the base adapter is unnecessary because the holder itself presents the flange the fork bears on. Knowing which of the two chains applies to a given bench is the difference between ordering one part and ordering three.
Key Features
- Three points of contact with the table. The relieved underside produces three small bearing areas rather than a full ring, which gives high stability and a clamp that does not rock on a table surface that has seen years of use.
- Full 360 degree swivel when loosened. Set the base position first, then rotate the fork to whichever tapped hole is closest, then tighten. The clamp direction is the last decision, not the first.
- 0.85 in (21.6 mm) counterbored slot. The short tier of the three fork lengths, sized for compact assemblies where adjacent hardware leaves no room for a longer bar.
- Stainless steel body. The slot does not gall or round over after repeated tighten-and-loosen cycles, and the part does not shed soft coating flakes at the contact points.
- 1/4 in-20 and M6 cap screw interface. One fork covers both thread standards, so a bench does not need two part numbers because one table is imperial and the other metric.
- Dimensioned for Ø1.85 in (47.0 mm) pedestal bases. Matches the flange diameter of PB4(/M) and PB4R(/M) rather than a generic 1.85 in footprint.
- Works with Ø1 in post holders and the BLP01. The base adapter is required only when the mount is built on a Ø1.5 in post; a post holder already provides the flange.
- Magnetic pre-location with PB4R. Four magnets in the adapter underside hold the base in place while both hands are free to position the fork, which turns a two-person job into a one-person job.
- Consumable-scale hardware, instrument-grade geometry. Nothing in the part wears out quickly, but the three-point geometry means a bent or substituted fork is not an acceptable stand-in.
- In stock as a single unit. One fork per order, for the bench that needs one more rather than a drawer refill.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | PF85B |
| Component type | Clamping fork for pedestal bases |
| Base compatibility | Ø1.85 in (47.0 mm) pedestal bases |
| Recommended base adapter | PB4(/M) or PB4R(/M), 303 stainless, 1.85 in (47.0 mm) OD |
| Adapter thread | 1/4 in-20 (PB4) or M6 (PB4/M) |
| Slot length | 0.85 in (21.6 mm) |
| Slot type | Counterbored slot |
| Cap screw interface | 1/4 in-20 or M6 |
| Body material | Stainless steel |
| Contact geometry | Three points of contact with the table surface |
| Rotation | 360 degrees around the post or post holder when the screw is loosened |
| Table compatibility | Imperial 1/4 in-20 and metric M6 optical tables and breadboards |
| Alternative mounting | Ø1 in post holder, or BLP01 adjustable-height post, without a base adapter |
| Quantity | Single unit |
| Availability | Held in stock |
Three rows in that table do most of the work. The slot length decides which fork you need; the contact geometry explains why the part behaves the way it does; and the base adapter row is the one that is most often got wrong, because the natural assumption is that a fork clamps a post. It does not. It clamps a flange, and a post has no flange at table level unless an adapter puts one there.
Applications
A single mount that has to hold position and be re-aimed often. A fork is the right hardware where the base is adjusted weekly rather than once. Loosen one screw, the fork swings clear, the base moves to a new hole, the fork swings back and the screw is re-tightened. The base never has to be lifted off the table, which is what preserves the height setting through the move.
Benches where one person does the changeover. With a magnetic PB4R adapter the base is located before the fork goes on. That sequence matters when there is no second pair of hands: the magnet holds the base roughly in place, the fork is dropped over the flange, and the screw is started with the base already stable. Without the magnet, the base tends to slide while the screw is being engaged.
The standard finishing part of a Ø1.5 in post build. A Ø1.5 in post on a PB4 base is a common way to build a tall, stiff mount. The fork is the part that turns that stack from something resting on the table into something bolted to it. Omitting it is a false economy that shows up as a slow drift in a long measurement.
Dense layouts where a long bar will not fit. The 0.85 in slot keeps the fork footprint small. On a breadboard where two bases sit close together, or where a fork has to reach between existing hardware, the short version is often the only one that will physically go in.
Prototype rigs that are re-laid-out between experiments. The combination of swivel and a single screw means a rig can be reconfigured without disturbing the bases that are staying. On a bench that changes weekly, that is the difference between a ten-minute change and an hour of realignment.
Selection Guide
Four decisions, in this order. The first one eliminates the wrong answers; the last one is where most ordering mistakes happen.
- Step 1, identify what the fork will clamp. If the stack is a Ø1.5 in post on a pedestal base, the answer is PB4(/M) or PB4R(/M) plus PF85B. If the stack is a Ø1 in post holder or a BLP01, the fork clamps the holder flange directly and no adapter is needed. If the base on the table is from another family with a different flange diameter, the fork will not seat correctly and no amount of tightening will fix it.
- Step 2, choose the slot length. 0.85 in (21.6 mm) for compact layouts. The 1.25 in (31.8 mm) and 2.12 in (53.8 mm) versions exist for larger adjustment ranges and for reaching past neighbouring hardware; choose the shortest one that reaches the tapped hole you actually intend to use.
- Step 3, choose PB4 or PB4R. PB4 for a permanent installation where the base is set once and left; it tightens with a 1/8 in (3 mm) hex key. PB4R where bases are moved, where the table is vertical or tilted during assembly, or where one person is doing the work; its four magnets hold the base while the fork is positioned, and it uses a 3/16 in (5 mm) hex key.
- Step 4, confirm the screw. A 1/4 in-20 cap screw on an imperial table, an M6 cap screw on a metric table. The counterbore is deep enough that the head sits below the fork surface, so an over-long screw will bottom out in the table hole before the fork is properly clamped.
A note on the 0.85 in choice specifically. The slot length is not a quality grade; a longer slot is not a better fork. It is a reach dimension. The 0.85 in version is the correct part when the base sits near its nominal position and the surrounding hardware is tight, and it is the wrong part when the nearest free tapped hole is 30 mm away from the base centre. Buying the short fork because it is the cheapest way into the family, then discovering the hole is out of reach, is a common and entirely avoidable mistake.
Series Comparison
| Model | Counterbored slot | Best suited to |
|---|---|---|
| PF85B (this page) | 0.85 in (21.6 mm) | Compact assemblies, bases near nominal position, tight neighbours |
| PF125B | 1.25 in (31.8 mm) | General purpose, bases a few millimetres off nominal |
| PF175B | 2.12 in (53.8 mm) | Bases placed by eye, offset holes, forks reaching past hardware |
All three share the same stainless body, the same three-point contact geometry, the same 1/4 in-20 and M6 screw interface, and the same 360 degree swivel. Slot length is effectively the only variable, which is convenient for standardisation and awkward for identification: the three parts look very similar in a drawer, and a fork with too short a slot will still accept a screw while clamping almost nothing. Keep one length per drawer.
There is a practical argument for standardising on one length across a laboratory even when a few positions would be better served by another. One length means one spare part number, one tightening habit, and no possibility of a mis-clamped base caused by picking the wrong bar out of a mixed box. The cost is that one or two positions end up slightly less convenient than they could be. On most benches that is the better trade.
FAQ
Q: Why does Thorlabs specify PB4(/M) or PB4R(/M) rather than a post series for this fork?
A: Because the fork clamps a flange and a post has no flange at table level. PB4 and PB4R are pedestal base adapters: flat circular flanges 1.85 in (47.0 mm) across with a threaded centre, screwed onto the bottom of a Ø1.5 in post so that the assembly sits directly on the table. The fork straddles that flange and pulls it down. A post on its own presents nothing for the fork to bear on.
Q: What is the difference between PB4 and PB4R?
A: PB4 is the plain version, tightened with a 1/8 in (3 mm) hex key. PB4R has a 3/16 in (5 mm) hex socket and four strong magnets in its underside, so the base can be located magnetically on a steel table before any clamp is applied. Both are solid 303 stainless with a 1.85 in (47.0 mm) outside diameter and a 1/4 in-20 or M6 threaded stud. Choose PB4R where bases get moved or where one person is doing the assembly.
Q: Can the fork be used with a Ø1 in post holder instead?
A: Yes. A Ø1 in post holder, or a BLP01 adjustable-height post, presents a flange at table level, and the fork clamps that flange directly. In that arrangement the PB4 adapter is not needed. The fork geometry is unchanged; what changes is which part supplies the flange the fork bears on.
Q: Does the fork rotate after it is tightened?
A: No, and that is the point. When the cap screw is loosened the fork swivels freely through 360 degrees around the post or post holder, so it can be aimed at whichever tapped hole is most convenient. Once the screw is tightened the fork is fixed, and the three-point contact is what keeps the base from creeping.
Q: How tight should the screw be?
A: Firm enough that the base cannot be moved by hand, and no more. Thorlabs warns that significant overtightening of clamping forks can deform the surface of an optical table, which can cause misalignment of components and decrease stability. The deformation is permanent and it is local, so the hole you damaged stays damaged. A short wrench and a light hand are the correct tools.
Q: Will it fit a table with M6 holes?
A: Yes. The fork accepts a 1/4 in-20 or an M6 cap screw, and the counterbore is sized so that either head sits below the fork surface. One part number covers both thread standards, which is what the universal description refers to.
Q: Is stainless steel necessary for a part that only clamps?
A: It matters more than it sounds. The slot is the working surface: every tighten-and-loosen cycle runs the screw shank against it. A harder body keeps the slot geometry, which is what keeps the clamp force repeatable. Stainless also avoids shedding soft coating flakes at the three contact points, which is relevant on a bench where particulate control already matters.
Usage Precautions
- Do not overtighten. Thorlabs states that significant overtightening of clamping forks can deform the surface of an optical table, which can cause misalignment of components and decrease stability. The dent is permanent, and it is in the one place you cannot machine back.
- Seat the screw head in the counterbore. If the head rests on the shoulder instead of dropping into the recess, the slot is not reaching the hole. Move the base or use a longer fork rather than forcing the screw.
- Start the thread by hand. A stainless screw run into a stainless fork at an angle will gall on the first turn. Engage two or three threads by hand before any wrench is applied.
- Check the flange diameter before assembly. The fork is sized for a 1.85 in (47.0 mm) flange. A base of a different diameter will be clamped on an edge rather than on the flange, and the three-point geometry will not be reproduced.
- Keep slot lengths separated in storage. The 0.85 in, 1.25 in and 2.12 in forks are visually close. A mixed drawer eventually produces a base that feels clamped and is not.
- Clean with solvent, not abrasives. Isopropanol and a lint-free wipe are sufficient to remove handling residue. An abrasive pad will round the counterbore shoulder and change the clamp geometry permanently.
- Retire a bent fork. A fork that has been dropped onto a hard floor may have one ear slightly out of plane. It will clamp at an angle and the base will creep. Compare it against a known-good part before returning it to service, and replace rather than straighten it.
Disclaimer
The mechanical description on this page follows the manufacturer published information for the PF85B clamping fork and its named base adapters, and is provided as selection support. Dimensional drawings and tolerances on the current datasheet take precedence over this summary, and specifications may be revised without notice. This page deliberately does not restate any price; price, availability and delivery are confirmed at the time of quotation. Where a build depends on the exact stack height of a base, adapter and fork, obtain the current drawing before committing the mechanical design.
Two dimensions belong to the base adapter rather than to the fork, and they are not restated here: the adapter height and the usable thread depth. Both come from the PB4 or PB4R drawing, and both affect the assembled height of the mount. A build that depends on the height of a post plus adapter plus breadboard should add those two documents together rather than assume that a 1.85 in flange implies a particular stack height.
Contact Us
For help deciding whether a given mount needs a pedestal base adapter at all, for confirmation that a fork will clear the hardware already on the table, or for a quotation, contact the sales team with the base model, the table thread standard and the distance from the base centre to the nearest free tapped hole. That last dimension is what decides the slot length, and it is the one piece of information most enquiries leave out.
Compatibility questions are usually settled fastest with a photograph. A picture of the existing base with a ruler or a hex key in frame is enough to confirm the flange diameter, and the flange diameter is the only dimension that decides whether this fork will seat or will clamp on an edge. Where the base is a custom part, send the drawing instead and the fit can be checked against the fork geometry directly.









Reviews
There are no reviews yet.