Thorlabs PFA51507 Active Isolation Breadboard Support Frame, 700 mm Height, 900 x 1200 mm

Thorlabs PFA51507 Active Isolation Breadboard Support Frame, 700 mm Height, 900 x 1200 mm

Price on request
Category:

Description

Product Overview

PFA51507 is an active isolation breadboard support frame from Thorlabs for a 900 x 1200 mm (36 in x 48 in) breadboard. It stands 700 mm (27.5 in) high, is rated to 700 kg (1,545 lbs), and stands on four independent, air mounted, active vibration isolators that provide pneumatic self-leveling with a repeatability of ±0.25 mm (0.010 in). The vertical resonant frequency is below 1.6 Hz, the horizontal resonant frequency is below 1.2 Hz, and the structure is all steel. Leveling pads give ±9.5 mm (±0.375 in) of adjustment and the leveling feet give ±5 mm (±0.2 in). The PWA061 caster set is an option. Continuous pressurised air is required for isolation.

This model occupies a specific place in the range, and it is easier to describe by the situation it solves than by its dimensions. It is the transition size between a bench that serves one experiment and a bench that serves two. A laboratory usually arrives here by a route that has nothing to do with optics: one instrument is no longer enough, two independent benches are not in this year’s budget, and the compromise has to hold both setups on one isolated surface without either of them being permanently second-class.

The dimension that makes that possible is the width. 900 mm is the threshold at which a person standing at either long edge can reach the centreline comfortably and at which a shared optical lane can run down the middle of the table with usable bench on both sides. At 900 mm width a 150 mm centre lane leaves 375 mm of working depth on each side, which is five rows of 75 mm modules. At 750 mm width the same lane leaves 300 mm on each side, which is four rows, and the lane has to be pushed to one edge because there is no middle to put it in.

The length is the second half of the argument. 1200 mm divides into two 600 mm stations, or into two 600 x 900 mm work zones of 0.54 m² each. That is enough for an instrument body and its immediate optics at each end, with the shared lane running between them. It is also the practical limit for two instruments placed back to back, because beyond about 1200 mm the far side of the bench stops being reachable from one position and the layout needs a second operator or a walkway.

The economics of the transition are worth stating with numbers. Two 750 x 750 mm benches provide 1.125 m² of surface between them, against 1.08 m² on this single frame: 104.2 percent of the area, so almost identical. But two benches need two frames, two air connections, two leveling systems and a gap between them, and with a 150 mm gap the floor footprint becomes 1.2375 m² against 1.08 m², which is 12.7 percent more floor for the same working surface. The single 900 x 1200 mm frame gives one continuous surface with no gap in the middle, one air line and one leveling reference.

What the frame does not change is the isolation. The isolators, the load rating, the 700 mm height and the 1.6 Hz and 1.2 Hz resonant frequencies are the same as on every other size in the PFA range, because they are the same components. What the larger outline changes is the base over which the load is spread, which improves tolerance to an off-centre payload, and the working area, which is what makes a two-station layout possible.

Key Features

  • 900 x 1200 mm (36 in x 48 in) outline, the only size in the range that combines a width above 750 mm with a length of 1200 mm. That combination is what allows a centre lane with usable bench on both sides.
  • A 150 mm centre lane leaves 375 mm of working depth on each side, which is five rows of 75 mm modules. A 750 mm wide frame leaves 300 mm, or four rows, for the same lane, so the extra width is worth one full row of optics on each side of the shared path.
  • 1200 mm length divides into two 600 x 900 mm work zones of 0.54 m² each, enough for an instrument body plus its immediate optics at each end with the shared lane running between them.
  • Four independent, air mounted, active vibration isolators, each carrying 175 kg (386 lbs) at the 700 kg rating. A wider base means a given off-centre load produces a smaller load difference between the near and far pairs than it would on a narrow frame.
  • Vertical resonant frequency below 1.6 Hz and horizontal resonant frequency below 1.2 Hz. The isolated band starts just above those corners, which covers footfall, door closure, pump rotation and building services.
  • The vertical element is a dual chamber damped pneumatic spring. The tabletop is supported on air pressure, sealed to the upper chamber by a rolling rubber diaphragm that allows near frictionless vertical travel while blocking horizontal movement, and damped by air forced through a high damping orifice between the chambers. The volume ratio of the two chambers is optimised for low resonant frequency and usable damping at once.
  • Trifilar suspension system in the horizontal direction. The vertical isolators rest on a three-wire pendulum, gravity supplies the restoring force, and an oil-free damper between each isolator base and the outer housing suppresses oscillation at the horizontal resonant frequency.
  • Pneumatic self-leveling to ±0.25 mm (0.010 in) repeatability. The three-way valve adjusts chamber pressure until the tabletop returns to its set point, and it compensates automatically when the load distribution changes, which on a two-station bench happens every time one side is reconfigured.
  • Sturdy all-steel construction. On a two-station bench the frame is the common reference for both experiments, so its dimensional stability under a temperature drift matters more than it does on a single-operator bench.
  • Height adjustment of ±9.5 mm (±0.375 in) on the leveling pads for working height and floor slope, and ±5 mm (±0.2 in) on the leveling feet for local unevenness. The 700 mm (27.5 in) height suits seated work, and an 800 mm (31.5 in) version is available for standing work.
  • Optional PWA061 caster set. Useful on a two-station bench because a shared bench is more likely to be rearranged as the two experiments evolve.
  • Continuous pressurised air required. Without air the tabletop settles onto its supports and the frame behaves as a rigid steel structure until pressure returns.
  • Transmissibility quoted separately for the vertical and the horizontal axis: below 13 dB and below 8 dB at resonance, -18 dB at 5 Hz and -34 dB at 10 Hz on each. Two stations sharing one table top load the frame asymmetrically, and an asymmetric load shows up in the two axes differently, so a single combined figure would hide the part that matters.
  • 98 percent isolation at 10 Hz in both axes, with the horizontal figure quoted rather than assumed. When the bench is shared, one station can be adding a delay line while the other is measuring, and the moment that load moves is a horizontal disturbance as much as a vertical one.

Technical Specifications

The manufacturer specifications below apply to this model and, for the isolation parameters, to every size in the PFA range. The values are listed with the metric figure first and the imperial equivalent second, because drawings from different suppliers and different decades use one or the other and a mismatch is a common source of layout error.

Parameter Specification Note
Ordering code PFA51507 Thorlabs catalogue number
Product class Active isolation breadboard support frame Support structure, not a breadboard
Breadboard size accepted 900 x 1200 mm (36 in x 48 in) Rectangular, four-point support
Frame height 700 mm (27.5 in) 800 mm (31.5 in) version also available
Load capacity 700 kg (1,545 lbs) Total, including breadboard and fixtures
Load per isolator at rating 175 kg (386 lbs) 700 kg divided by four
Isolator configuration Four independent, air mounted, active One at each corner
Leveling method Pneumatic self-leveling Three-way valve, no electronics
Leveling repeatability ±0.25 mm (0.010 in) Return to level after a disturbance
Vertical resonant frequency below 1.6 Hz Lower edge of the isolated band
Horizontal resonant frequency below 1.2 Hz Set by the trifilar suspension
Vertical transmissibility at resonance below 13 dB Gain at the corner before attenuation
Horizontal transmissibility at resonance below 8 dB The lower of the two peaks
Vertical transmissibility at 5 Hz -18 dB (87.5%) 87.5% removed at five hertz
Horizontal transmissibility at 5 Hz -18 dB (87.5%) Same removal in the horizontal axis
Vertical transmissibility at 10 Hz -34 dB (98%) 98% removed, 2% transmitted
Horizontal transmissibility at 10 Hz -34 dB (98%) Both axes settle by ten hertz
Vertical isolation element Dual chamber, damped pneumatic spring Rolling diaphragm, orifice damping
Horizontal isolation element Trifilar suspension system Gravity restoring force, oil-free damper
Structure All-steel construction Welded tubular frame
Finish Black Paint Painted steel frame
Height adjustment, pads ±9.5 mm (±0.375 in) Working height and floor slope
Height adjustment, feet ±5 mm (±0.2 in) Local floor unevenness
Isolators height adjustment range ±6 mm (0.25 in) Travel in the pneumatic element
Legs height adjustment range ±10 mm (0.4 in) Trimmed once, at installation
Total height range of the system 26 mm (1.02 in) Isolators plus legs, breadboard travel
Optional mobility PWA061 caster set Ordered separately
Air supply Continuous pressurised air Clean, dry, regulated
Air pressure required 690 kPa (100 psi) maximum Regulated, at the frame inlet
Behaviour without air Tabletop settles onto its supports Rigid frame until pressure returns
Largest breadboard in the family 1200 x 1800 mm (48 in x 72 in) Not applicable to this model

How the transmission rows should be read: each decibel value is twenty times the logarithm of the ratio of tabletop motion to floor motion, so the bracketed percentage is the proportion of floor vibration that the frame removes. -34 dB means roughly 2.0 percent of the motion is passed, which is 98 percent isolation, and -18 dB means roughly 12.6 percent is passed, which is the 87.5 percent the datasheet states. These percentages are not transmission coefficients. The height figures need the same care for a different reason. The Features list quotes leveling pads at ±9.5 mm and leveling feet at ±5 mm; the rows above quote isolators at ±6 mm and legs at ±10 mm. The first pair are static adjusters, the second pair are travel limits of the pneumatic element and the leg, and a laboratory comparing them will otherwise conclude that one of the two is wrong. Size from the table. The 26 mm entry is the combined breadboard height range, and the corner frequencies are upper limits: below 1.6 Hz vertically and below 1.2 Hz horizontally.

The tables that follow are derived from the outline rather than published. They exist because the decision this frame answers is a width decision, and a width decision is easier to make with a row count than with a millimetre figure.

Tabletop Width Reach to Centreline Working Area per Metre of Length Rows of 75 mm Modules, No Lane Rows with a 150 mm Centre Lane Rows with a 200 mm Centre Lane
900 mm 450 mm 0.9000 m² 6 rows 5 rows 4 rows
750 mm 375 mm 0.7500 m² 5 rows 4 rows 3 rows

The difference between the two rows is one row of modules on each side of the table, once a shared lane is present. That is what the extra 150 mm of width buys, and it is the whole justification for choosing this model over the 750 x 1200 mm frame when the layout has to carry two setups rather than one. Without a centre lane the two widths differ by one row; with a lane the difference is still one row but the narrow frame has no middle left to place it in.

The next table puts the transition economics on paper. It compares this frame with two small benches, which is the alternative a laboratory usually considers when one instrument stops being enough.

Criterion One 900 x 1200 mm Frame Two 750 x 750 mm Benches Comment
Working surface 1.08 m² 1.125 m² Two small benches give 4.2 percent more surface
Floor footprint, 150 mm gap 1.08 m² 1.2375 m² The single frame uses 12.7 percent less floor
Number of frames 1 2 One frame, one installation
Number of air connections 1 2 One filter-regulator, one line
Leveling references 1 2 One continuous reference surface
Gap in the working surface none 150 mm No beam path interruption on one frame
Station size available 2 x 0.54 m² 2 x 0.5625 m² Comparable per station

The comparison is closer than it looks in the surface column, which is why the argument has to be made on continuity rather than on area. Two benches give slightly more total surface and slightly more surface per station. One frame gives a continuous plane with no gap, one air line, one leveling reference and less floor. For a layout where a beam has to cross from one station to the other, the continuous plane is decisive; for two experiments that will never share light, two separate benches are a legitimate choice and are easier to move one at a time.

Applications

This frame is specified where two experiments have to coexist on one isolated surface. The applications below are the recurring versions of that situation.

  • Two independent experiments sharing one bench. One station at each end, each with its own source, sample position and detector, and no optical connection between them. The value of the single frame is that both stations sit on the same leveling reference and the same air supply, so a facility problem affects both at once instead of being discovered separately.
  • Two workstations sharing a common optical path. A source at one end feeding two experiment arms, with the split and the shared beam running down the centre lane. This is the layout the 900 mm width was made for: 375 mm on each side of a 150 mm lane is enough to build a full arm on both sides without either arm crowding the shared path.
  • A layout that needs a cable and service route down the middle. Not every centre lane carries light. On a bench with motorised stages, cameras and detectors at both ends, running services down a 150 mm strip in the middle keeps them out of the optics, and the wider frame is what makes that strip affordable in bench area.
  • A general-purpose bench during a laboratory expansion. The period between deciding that more bench space is needed and having the budget and the room for it is often two or three years. A 900 x 1200 mm frame carries a single experiment comfortably during that period and carries two when the second one arrives, so it does not have to be replaced at the moment the laboratory grows.
  • Interferometry with a reference arm and a measurement arm. A two-arm layout maps naturally onto two stations with a shared split, and the 1200 mm length gives each arm enough room to fold once without crowding.
  • Inspection or measurement cells with a load and an unload position. Where a sample is prepared at one end and measured at the other, the two positions can share one isolated surface, which removes the transfer of a mounted sample between benches as a source of misalignment.

Selection Guide

The question this frame answers is not how much area is needed but whether the layout needs a continuous surface wide enough for two setups. Work through the following in order.

  1. Decide whether the two setups will share light. If a beam crosses from one to the other, a single frame with a continuous surface is almost always the right answer and the 900 x 1200 mm outline is the smallest that carries two stations plus a shared lane. If the two experiments will never interact, two separate benches are cheaper per square metre and can be moved independently.
  2. Check the width against the lane. If a 150 mm centre lane is required, 900 mm leaves 375 mm on each side and 750 mm leaves 300 mm. Measure the deepest module on the layout: a translation stage with a motor and a cable exit commonly needs 100 mm to 150 mm of depth, so the difference between five rows and four rows is the difference between fitting the stage and hanging it over the edge.
  3. Check the length against the stations. 1200 mm divides into two 600 mm stations. If either station needs more than 600 mm of length, the two stations will not fit and the 1500 mm or 1800 mm outlines should be considered. If each station needs less than 500 mm, the 750 x 1200 mm frame may be enough if no centre lane is needed.
  4. Estimate the mass and apply a margin. Two stations usually weigh more than one, but a 900 x 1200 mm bench still rarely approaches 700 kg. Add the breadboard, both stations, the cabling and 20 to 30 percent for growth, and compare with a working budget of 490 kg to 560 kg.
  5. Check the centre of gravity across the width. The wider base helps here: with the support points further apart, the same offset produces a smaller load difference between the near and far pairs. The risk on a two-station bench is not total mass but asymmetry, with a heavy instrument at one end and a light one at the other. Place the heavier instrument nearer the centre and put ballast low if the imbalance is large.
  6. Choose the frame height. 700 mm (27.5 in) for seated work, 800 mm (31.5 in) for standing work. On a two-station bench where two people work at once, standing height is often preferred because it lets both operators move around the frame.
  7. Decide on the PWA061 caster set. A shared bench gets rearranged as the two experiments evolve, so casters are more often justified here than on a single-station bench.
  8. Confirm air, floor and access. One air line is simpler than two, which is an advantage of the single frame. A 900 x 1200 mm frame needs a wider route than a 750 mm bench: check door widths, corridor turns and lift dimensions, and confirm the floor point loading of 175 kg (386 lbs) per corner at rating.

Series Comparison

The PFA range shares one isolator design across six outlines. The comparison below is organised around the two dimensions separately, because on this model the width is the deciding dimension and the length is secondary.

Model Breadboard Size Area (m²) Clear Span Position in the Range
PFA51509 750 x 750 mm 0.5625 650 mm Single setup, one operator
PFA51505 750 x 900 mm 0.6750 800 mm Single workstation, short beam path
PFA51508 750 x 1200 mm 0.9000 1100 mm Long straight path, no centre lane
PFA51507 900 x 1200 mm 1.0800 1100 mm Two stations or a shared centre lane
PFA51502 900 x 1500 mm 1.3500 1400 mm Multi-station, long shared path
PFA51504 1200 x 1500 mm 1.8000 1400 mm Largest outline, room-scale base

The step from PFA51508 to PFA51507 is the one worth studying, because the two models have the same 1200 mm length and the same 1100 mm clear span. They differ only in width, and the width difference is 150 mm. That 150 mm converts into one row of modules on each side of a centre lane, which is the difference between a two-station layout that works and one that has stages overhanging the edge. On this pair, area is the wrong metric: 0.90 m² against 1.08 m², a 20 percent difference that sounds like a modest upgrade but delivers a qualitatively different layout capability.

The step from PFA51507 to PFA51502 is the opposite kind of change. Going to 900 x 1500 mm adds 300 mm of length, which extends each station and lengthens the shared path, but it does not add width and therefore does not add rows. A layout that is width-limited rather than length-limited gains nothing from that step. That distinction, width-limited against length-limited, is the one to settle before comparing prices.

FAQ

Is 900 x 1200 mm really different from 750 x 1200 mm, or is it just more area?

It is different in kind. Both have the same 1200 mm length and the same clear span, and the areas differ by 20 percent, from 0.90 m² to 1.08 m². The difference that matters is the width: at 900 mm a 150 mm centre lane leaves 375 mm of working depth on each side, which is five rows of 75 mm modules, while at 750 mm the same lane leaves 300 mm, which is four rows. One row per side is the difference between a stage fitting and a stage overhanging.

Why not just buy two smaller benches instead?

Two 750 x 750 mm benches give 1.125 m² of surface against 1.08 m² here, so the area is comparable. But two benches need two frames, two air lines, two leveling references and a gap between them: with a 150 mm gap the floor footprint is 1.2375 m² against 1.08 m², which is 12.7 percent more floor. If a beam has to cross from one station to the other, the gap in a two-bench layout is a real optical problem, and the continuous surface of this frame removes it.

Can two people work at this bench at the same time?

Yes, one at each end, which is why the 600 mm station division matters. Working along the long edges is also possible: the reach to the centreline from a long edge is 450 mm, which is inside comfortable working reach for most people. What does not work is two people at the same long edge, because 900 mm of depth shared between two operators leaves neither of them enough room.

Does the wider base make the frame more stable?

Yes, in the sense that a given off-centre load produces a smaller difference in load between the near and far isolator pairs, because the support points are further apart. The stability warning that applies to narrow tabletops with a high centre of gravity is correspondingly less acute here than on the 750 mm square model. It does not disappear: a tall riser carrying a heavy compressor will still raise the centre of gravity and the layout should still keep mass low.

What is the load rating, and is it enough for two stations?

700 kg (1,545 lbs), which is 175 kg (386 lbs) per isolator at rating. Two instrument stations plus a breadboard typically total well under half of that, so the rating is not the constraint. The constraint on a two-station bench is distribution rather than total: a heavy instrument at one end and a light one at the other shifts the centre of gravity along the length, and the leveling valve will correct the resulting tilt within ±0.25 mm but the static load difference remains.

Can the centre lane carry a beam at a different height from the two sides?

Yes. The lane is a layout convention, not a physical feature of the frame, so the shared beam can run at whatever height the split and recombination optics require. What the width provides is the space to route it without crowding the working areas on either side. If the shared path needs to be enclosed in a tube for stray light or purge, allow for the tube diameter when calculating the lane width.

How does the leveling cope when one station is dismantled?

The valve senses the change in tabletop height and adjusts chamber pressure until the tabletop returns to its set point, and it compensates for the change in load distribution at the same time. The result is a bench that stays level to ±0.25 mm (0.010 in) as stations are built, stripped and rebuilt, which is exactly the pattern a shared bench sees over a project.

What happens without air pressure?

The tabletop settles onto its supports and the frame behaves as a rigid steel structure. Nothing is damaged and alignment is preserved if the descent is gentle. When pressure returns the tabletop lifts and re-levels within ±0.25 mm, so a two-station experiment can usually continue without realignment of either station.

Is a 900 x 1200 mm frame harder to install than a smaller one?

Yes, mainly on the access route. A 750 mm wide bench passes a standard 800 mm door; a 900 x 1200 mm frame needs a route with at least a metre of clearance and enough turning room for a 1200 mm long object. Check door widths, corridor corners and lift dimensions before ordering, and note that the frame is all steel and needs two people to handle safely.

Which is the better choice for a growing laboratory, this frame or the 900 x 1500 mm?

If the growth is a second station placed beside the first, this frame is enough: it already provides two 600 x 900 mm zones and a centre lane. If the growth is a longer shared beam path or a third station, the 1500 mm length of PFA51502 is the better fit, because it extends each station rather than adding width. Decide whether the limitation is width or length before comparing the two.

Usage Precautions

A two-station bench introduces coordination problems that a single-operator bench does not have. The precautions below are written for that situation, on top of the usual requirements for air supply, leveling and floor loading.

  • Agree the centre lane before either station is built. The lane is the resource the two stations share, and it is the first thing to be encroached on when one station grows. Mark it on the breadboard drawing, agree its width and its beam height, and treat it as fixed. A lane that drifts to one side turns a 900 mm bench into a 750 mm bench with extra cost.
  • Balance the load along the length. Two stations of very different mass tilt the tabletop and shift the centre of gravity. The leveling valve corrects the tilt within ±0.25 mm, but the static load difference between the near and far isolator pairs remains and reduces the margin on the light end. Put the heavier instrument nearer the centre and add ballast low if the imbalance is large.
  • Keep services out of the optics. Two stations mean twice the cables, twice the coolant lines and twice the chance that a cable loop touches a mount. Use the centre lane or the underside for routing, strain-relieve every cable at the breadboard edge, and keep coolant lines off the tabletop where a leak would reach the optics.
  • Provide one clean, dry, regulated air supply with a visible gauge. One air line is an advantage of the single frame, but it is also a single point of failure for both stations. Fit a filter-regulator, drain it regularly, and put a gauge where both operators can see it so that a pressure loss is noticed before it becomes a data problem.
  • Level mechanically before pressurising, and re-level after moving. Set the frame roughly level on its pads and feet first, then bring up pressure. If the PWA061 casters are fitted, lower onto pads or feet and let the valve settle before either station takes data.
  • Respect the 175 kg per corner at rating. A 900 x 1200 mm frame spreads a heavy load better than a small one, but each corner still carries a quarter of the total. On a raised access floor, check the panel rating and use spreader plates if the point load is marginal.
  • Check the access route before delivery. The frame is all steel, 900 mm wide and 1200 mm long. Door widths, corridor corners and lift dimensions decide whether delivery is a straightforward carry or a rigging job, and that decision is much cheaper to make before the frame is on a lorry.
  • Keep diaphragms clean and free of solvent. The rolling rubber diaphragm is the seal that allows frictionless vertical travel. A solvent spill or a sharp edge against the diaphragm ends the isolator’s ability to hold pressure, and on a shared bench spills are more likely because more work is happening.
  • Do not stand on the bench or use it as a shelf. A shared bench attracts clutter at both ends. Loads at the edge and high up are the worst case for the leveling system and for stability, and an unattended box on the corner is a load the other operator does not know about.
  • Allow settling time after any change at either station. Adding or removing mass at one end moves the whole tabletop. Give the valve time to settle and the breadboard time to stop ringing before recording data at the other end.

Disclaimer

The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and the manufacturer may revise specifications without notice.

The derived tables are calculations, not manufacturer data. Working areas, reach distances, row counts, floor footprints and the comparison with two small benches all depend on the assumptions stated with them: a 75 mm module row pitch, a 150 mm or 200 mm centre lane, and a 150 mm gap between two benches. Change the assumptions and the row counts change. Use the tables to compare outlines, not to certify a layout.

Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the payload installed, the floor the frame stands on and the quality of the air supply. No transmission curve is reproduced here; where a project requires a specific isolation performance at a specific frequency, request current performance data for the exact configuration.

No price is stated on this page. Availability, lead time and price are confirmed at the time of enquiry and may change with stock and currency. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.

Contact Us

For a quotation on PFA51507, or for help deciding whether the two-station layout will fit, send a sketch of both stations with the centre lane marked, the depth of the deepest module on each side, the estimated total mass and its distribution along the length, and confirmation that a continuous air supply is available. Those details settle the width question, which is the question this model exists to answer.

For a project comparing this frame with two smaller benches or with the 900 x 1500 mm model, say so in the enquiry and include the floor area available and the access route dimensions. The comparison turns on continuity of surface and on floor footprint rather than on price per square metre, and both are easier to judge with the room dimensions in hand.