Product Overview

PFA52507 is an active isolation breadboard support frame for a 900 x 1200 mm (36 in x 48 in) breadboard, built on an 800 mm (31.5 in) high frame. It carries 700 kg (1,545 lbs) on four independent, air mounted, active vibration isolators. The vertical resonant frequency is below 1.6 Hz, the horizontal resonant frequency is below 1.2 Hz, vertical transmissibility at resonance is below 13 dB and horizontal transmissibility at resonance is below 8 dB. At 5 Hz both axes sit at -18 dB, which is 87.5% of the ground motion removed; at 10 Hz both axes sit at -34 dB, which is 98% removed. Leveling is pneumatic and self-acting to ±0.25 mm (0.010 in) repeatability, the construction is all steel in Black Paint, the air requirement is 690 kPa (100 psi) maximum, and the PWA061 caster set is optional.

The most useful fact about this frame is also the least obvious one. The manufacturer publishes a single specification table that covers both the 700 mm and the 800 mm version of every outline in the range, and that table contains the resonant frequencies, the transmissibility at resonance, the transmissibility at 5 Hz and at 10 Hz, the 700 kg capacity, the ±0.25 mm leveling repeatability and the 690 kPa air requirement. Nothing in it changes with frame height. The reason is structural: the isolation is produced by the four isolators, and the isolators are the same components on both frames. The frame is only the structure that holds them apart and carries the load down to the floor.

That single fact settles a question that comes up in almost every enquiry about the two heights. Buyers assume that a taller frame is a compromise – that 100 mm of extra height must be paid for somewhere in the vibration performance, because a taller structure is a more flexible structure. It is a reasonable assumption and it is wrong here. The manufacturer’s own data says the two heights isolate identically, and the design reason is that the leg structure is stiff enough that its own modes sit well above the isolation band, so it behaves as a rigid link between the isolators and the floor over the frequency range that matters.

What the 100 mm does change is the height of the centre of gravity, and that is a real effect even though it is not an isolation effect. Every kilogram on the bench – the breadboard, the laser head, the stages, the detectors – sits 100 mm higher than it would on the 700 mm frame. For a frame that resists a lateral push by its own weight and its base width, that directly reduces the margin against tipping, and it changes the frequency of the rocking mode that the trifilar suspension has to control. The estimates in the selection guide below put the reduction at about 10 percent of the critical lateral force and about 2.4 degrees of critical tilt angle for a typical payload, which is a margin that is comfortable but no longer generous.

The second thing this outline does is fix a number that is worth knowing precisely. The 900 mm depth is the minimum depth at which two operators can face each other across the bench and both work comfortably. Each operator gets 450 mm of depth. The comfortable working reach of a 50th percentile operator, measured from a standing position 100 mm back from the front edge, is about 442 mm. The two figures differ by 8 mm, which means a 900 mm deep bench is exactly, and only just, a two-person face-to-face station. Nothing can be shared across the centre line and nothing can be placed in the middle for both people to reach. A 1200 mm depth gives each operator 600 mm and therefore 158 mm of slack, which is what a genuinely shared bench looks like.

Along the 1200 mm width each operator has about 884 mm of comfortable lateral coverage from a single stance, so the outer 158 mm at each end is outside the comfortable band and belongs to items that are set once. That is not a defect of the outline; it is the reason a 900 x 1200 mm bench is described as a two-station bench rather than a four-station one. Two people, one at each long side, each working the central 884 mm of their own half, is exactly what the geometry supports.

The outline itself is 1.08 m2 with a 4200 mm perimeter, a 1500.0 mm diagonal and a 1 to 1.333 aspect ratio, which leaves about 1000 mm of clear span along the 1200 mm axis after 100 mm at each end is reserved for mounts and beam clearance. That span is enough for a folded interferometer, a two-pass amplifier or a pump-probe delay line without an intermediate fold, which is the practical reason to choose 1200 mm over 900 mm of length.

The sections below deal in turn with the isolation principle that makes the two heights equivalent, with the centre of gravity arithmetic that makes them different anyway, with the two-operator geometry, and with the comparison against passive and rigid alternatives. The comparison table against passive frames is the one to read if the question is whether an active frame is needed at all rather than which height to order.

Key Features

  • 800 mm (31.5 in) frame height, giving a working surface of 825 to 910 mm once a breadboard of 25 to 110 mm is fitted, and an optical axis of roughly 925 to 1060 mm above the floor.
  • 900 x 1200 mm (36 in x 48 in) outline: 1.08 m2 of surface, 4200 mm of perimeter, a 1500.0 mm diagonal and about 1000 mm of clear span along the 1200 mm axis.
  • 900 mm depth is the exact minimum for two operators facing each other: each gets 450 mm against a comfortable working reach of about 442 mm, leaving 8 mm of slack.
  • Vertical resonant frequency below 1.6 Hz and horizontal resonant frequency below 1.2 Hz, identical to the 700 mm version of the same outline because the isolators are the same parts.
  • Vertical transmissibility below 13 dB and horizontal transmissibility below 8 dB at resonance, against 24 dB for a standard passive frame, which amplifies by a factor of about 16 at its corner.
  • Vertical and horizontal transmissibility of -18 dB at 5 Hz, which is 87.5% of the ground motion removed on both axes and is the figure that matters for foot traffic and building pressure waves.
  • Vertical and horizontal transmissibility of -34 dB at 10 Hz, which is 98% removed, against -16 dB for a passive frame at the same frequency.
  • 700 kg (1,545 lbs) total capacity, which is 175 kg per isolator when the load is evenly shared, and which includes the mass of the breadboard itself.
  • Dual chamber, damped pneumatic spring vertically: the breadboard rides on the pressure in the air chamber, the piston is sealed to the upper chamber by a rolling rubber diaphragm, and air forced through a high damping orifice between the chambers damps the oscillation and shortens settling.
  • Trifilar suspension horizontally: the pneumatic isolators stand on a three wire pendulum whose restoring force comes from gravity, with oil free damping to suppress the horizontal resonance.
  • Pneumatic self-leveling through precision three-way valves actuated by the motion of the working surface, returning it to within ±0.25 mm (0.010 in) and compensating automatically for changes in load distribution.
  • Isolator height adjustment of ±6 mm (0.25 in) and leg height adjustment of ±10 mm (0.4 in), with 26 mm (1.02 in) of total system travel available for trimming the installed height.
  • 690 kPa (100 psi) maximum air pressure, required continuously; with the air removed the breadboard rests securely on top of the frame and the isolation system is disabled.
  • All steel construction in Black Paint, which keeps the frame stiff and dimensionally stable under a static load and gives a predictable thermal response.
  • Four independent isolators, so that a load placed towards one end is shared rather than carried by two, and so that the self-leveling system has something to work with when the load moves.
  • PWA061 caster set available as an option: 360 degree swivel, non marking polyurethane wheels, 200 kg (440 lbs) per caster and 800 kg (1,760 lbs) for the set of four.

Technical Specifications

The table below reproduces the manufacturer data for this model. The isolation rows are shared with every other outline and both frame heights in the PFA range; the rows that are specific to this model are the breadboard size, the frame height and the geometry derived from the outline.

Specification Value
Model PFA52507
Product class Active isolation breadboard support frame
Breadboard size accepted 900 x 1200 mm (36 in x 48 in)
Frame height 800 mm (31.5 in)
Vertical resonant frequency below 1.6 Hz
Horizontal resonant frequency below 1.2 Hz
Vertical transmissibility at resonance below 13 dB
Horizontal transmissibility at resonance below 8 dB
Vertical transmissibility at 5 Hz -18 dB (87.5% isolation)
Horizontal transmissibility at 5 Hz -18 dB (87.5% isolation)
Vertical transmissibility at 10 Hz -34 dB (98% isolation)
Horizontal transmissibility at 10 Hz -34 dB (98% isolation)
Load capacity 700 kg (1,545 lbs)
Load per isolator at rated capacity 175 kg (386 lbs) when evenly shared
Isolators height adjustment range ±6 mm (0.25 in)
Self leveling repeatability ±0.25 mm (0.010 in)
Legs height adjustment range ±10 mm (0.4 in)
Air pressure required 690 kPa (100 psi) maximum
Finish Black Paint
Construction All steel
Isolator count and type Four independent, air mounted, active vibration isolators
Leveling method Pneumatic self-leveling, precision three-way valves
Optional casters PWA061 (set of 4)
Largest breadboard supported by family 1200 x 1800 mm (48 in x 72 in)
Outline area 1.0800 m2
Outline perimeter 4200 mm
Outline diagonal 1500.0 mm
Aspect ratio 1 to 1.333, long axis 1200 mm
Clear span along the 1200 mm axis about 1000 mm after 100 mm at each end for mounts

Table 1. Manufacturer specification for PFA52507, with outline geometry and per-isolator load derived from the stated breadboard size and capacity.

The per-isolator row is an addition rather than a manufacturer figure, and it is there because 175 kg per isolator is the number that decides whether a heavy instrument can be placed at one corner. The self-leveling system will compensate for an off centre load within its range, but it cannot move load from one isolator to another, and an isolator that is driven past its stroke stops isolating. A 200 kg instrument placed over one corner of this bench takes that isolator to the edge of its share before anything else is added.

Two notes on the height adjustment rows. The ±6 mm and ±10 mm figures refer to different components: 6 mm each way is the travel of the isolators themselves, and 10 mm each way is the travel of the leveling feet at the bottom of the legs. The manufacturer product description separately quotes leveling pads at ±9.5 mm (±0.375 in) and leveling feet at ±5 mm (±0.2 in), which are different parts described in a different place; for selection the specification table above governs. The 26 mm (1.02 in) figure that also appears in the manufacturer text is the total height range of the assembled system, not a third adjustment.

On the transmissibility figures, the percentages in brackets are the isolation and not the transmission. A figure of -34 dB is a transmission factor of 0.0200, so 2.0 percent of the ground motion reaches the breadboard and 98 percent does not; a figure of -18 dB is a factor of 0.1259, so 12.6 percent gets through and 87.4 percent is removed, quoted by the manufacturer as 87.5 percent. The negative sign indicates attenuation, so a more negative number and a larger percentage both mean better isolation.

The vertical mechanism is a dual chamber, damped pneumatic spring. The breadboard is supported on the pressure inside an air chamber and sits on a piston; the seal between the piston and the upper chamber is a rolling rubber diaphragm, which permits almost frictionless vertical motion while blocking horizontal displacement. Floor or bench motion forces air through a high damping orifice from the lower chamber to the upper chamber, which damps the oscillation and shortens the settling time. The two chamber volumes are sized so that the damping is maximised while the resonant frequency is kept low.

The horizontal mechanism is a trifilar suspension. The pneumatic vertical isolators stand on a three wire pendulum, so the restoring force after a lateral displacement is gravitational rather than elastic, and oscillation at the horizontal corner is suppressed by oil free dampers connecting the bottom of each vertical isolator to the outer cylinder. It is worth converting the two resonant frequencies into the equivalent static deflection they imply, because that makes the design tangible: a corner at below 1.6 Hz corresponds to a spring that would compress about 97 mm under its own load, and a corner at below 1.2 Hz corresponds to a pendulum of about 173 mm effective length. At the full 700 kg the implied stiffness is about 70.7 kN/m vertically and about 39.8 kN/m horizontally. These are derived figures, not manufacturer data, but they explain why the height adjustment ranges are small: the system is soft by design, and the leveling valves hold the position that the soft spring would otherwise lose.

Leveling is performed by precision three-way valves that are actuated by movement of the working surface itself. A disturbance that tilts the breadboard opens the appropriate valve, admits or exhausts air, and returns the surface to within ±0.25 mm of its original level; the same mechanism absorbs the change when equipment is added or removed at one end. When the air supply is removed the breadboard rests securely on top of the frame with the isolation system disabled, so the bench degrades to a rigid table rather than to an unstable one.

Applications

The applications below are the ones where a 900 x 1200 mm surface at 800 mm is doing work that a smaller or lower frame cannot do. The common thread is that each of them needs either two people at the same bench or a clear span of about a metre.

  • Two-operator pump-probe and transient absorption benches. One person runs the pump arm, the other the probe arm, and they need to see the same sample. The 900 mm depth gives each operator their own 450 mm band with the sample on the centre line, which is the geometry this outline was sized for.
  • Folded interferometers with a metre of clear span. A Michelson with a long reference arm, a Mach-Zehnder with a delay leg, or a white light interferometer all benefit from 1000 mm of uninterrupted run. That span removes one fold from most layouts, and one fold is worth about 3 percent of the light as well as one set of dispersive mirrors on an ultrafast system.
  • Multi-pass amplifier and regenerative cavity benches. A regenerative cavity needs a long folded path by construction, and putting that cavity on a metre of span keeps the external folds few. The low horizontal corner matters here because a lateral shift of the cavity mirrors changes the mode matching.
  • Holography and digital holographic microscopy. Both need a stable reference beam over a path of a metre or more, and both are sensitive to lateral drift rather than vertical drift. The below 1.2 Hz horizontal corner and the -34 dB at 10 Hz on the horizontal axis are the relevant figures.
  • Shared teaching and research benches. A bench that two students can work at simultaneously, that is 800 mm high so both can stand at it, and that carries 700 kg so a reasonably heavy laser can be bolted down without a separate support. The PWA061 casters let it be moved between sessions with the breadboard fitted.
  • Optical coherence tomography and swept-source imaging development. These layouts are long and thin: a source arm, a reference arm with a delay, and a sample arm. A 1000 mm clear span along 1200 mm holds all three without crossing the beams more than necessary, and the two-person geometry lets one operator hold a sample while the other adjusts.
  • Beam delivery and fibre launch stations feeding a larger experiment. A bench that sits at the head of a larger table, prepared and aligned independently, then delivered to the main experiment. The 800 mm height matches a standing operator and, if the main table is also on an 800 mm frame, the two axes line up without a periscope.

Selection Guide

The selection procedure for this frame has two independent parts, and they should be done separately because they can give opposite answers. The first part is the working height and the two-operator geometry, which is straightforward arithmetic. The second part is the centre of gravity, which is the only respect in which the 800 mm frame is worse than the 700 mm frame, and which is worth quantifying rather than assuming.

Start with the depth, because on this outline it is fixed and it decides how many people the bench serves. Two operators facing each other divide the 900 mm depth into two 450 mm bands. The comfortable working reach of a 50th percentile operator standing 100 mm back from the edge is about 442 mm, so each operator can reach all but 8 mm of their own band and nothing on the other side of the centre line. If the experiment needs anything shared – a sample holder, a common detector, a beam splitter that both arms pass through – then either the shared item sits exactly on the centre line and both operators accept a small stretch, or the bench has to be 1200 mm deep. That is the whole difference between this outline and the 1200 x 1500 mm frame in the same family.

Then take the centre of gravity. A frame resists a lateral push by its own weight acting through the base half-width, so the critical lateral force at which it would begin to tip is the total mass times gravity times the base half-width divided by the height of the centre of gravity. Using a base half-width of 450 mm, which is the breadboard half-width and therefore an optimistic upper bound on the real footprint, and a 700 kg total mass, the estimates are as follows. They treat the assembly as a rigid body, which it is not – the air springs are deliberately soft – so they describe the geometry of the problem rather than a load rating.

Payload condition Centre of gravity height, 700 mm frame Centre of gravity height, 800 mm frame Critical lateral force, 700 mm frame Critical lateral force, 800 mm frame Critical tilt angle, 700 / 800 mm
60 mm board, equipment centroid 100 mm above surface, 700 kg total 830 mm 930 mm 3723 N 3323 N 28.5 / 25.8 deg
60 mm board, equipment centroid 200 mm above surface, 700 kg total 930 mm 1030 mm 3323 N 3000 N 25.8 / 23.6 deg
60 mm board, equipment centroid 300 mm above surface, 700 kg total 1030 mm 1130 mm 3000 N 2735 N 23.6 / 21.7 deg
Same as the first row but only 500 kg total 830 mm 930 mm 2659 N 2373 N 28.5 / 25.8 deg
Same as the first row but only 350 kg total 830 mm 930 mm 1862 N 1661 N 28.5 / 25.8 deg

Table 2. Rigid body estimate of tipping margin, calculated as mass times gravity times base half-width divided by centre of gravity height, with a 450 mm base half-width. This is an estimate for comparison, not a manufacturer load rating; the air springs are soft and the real limit is reached earlier, by lateral excursion of the suspension.

Three things follow from that table. The first is that 100 mm of frame height is exactly equivalent, for tipping purposes, to putting a 100 mm taller instrument on the bench: the middle row of the 800 mm frame and the first row of the 700 mm frame give the same 930 mm centre of gravity and the same 3323 N. If a buyer would not worry about a 100 mm taller laser head, they should not worry about the taller frame, and vice versa.

The second is the size of the effect. Moving from 700 mm to 800 mm reduces the critical lateral force by about 10 percent and the critical tilt angle by about 2.4 degrees, in each case for a given payload. That is not a small number and it is not a large one. It matters for a bench that will be pushed, leaned on or moved on casters; it does not matter for a bench that stands still in a laboratory and is never touched except by hands on a kinematic mount.

The third is that mass matters more than height. Halving the total mass from 700 kg to 350 kg halves the critical lateral force, from 3323 N to 1661 N on the 800 mm frame, which is a 50 percent reduction against the 10 percent from the extra 100 mm. A lightly loaded tall bench is a worse proposition than a fully loaded one, and a bench with a heavy laser at one end and nothing at the other is worse still, because the mass is there but the centre of gravity has moved towards the loaded corner. If the payload is much lighter than the rating, add mass low down rather than accepting the loss of margin.

The one caveat about the equivalence of the two heights is worth stating. The isolation specification is published once for both heights, which means the manufacturer is satisfied that the leg structure of the taller frame does not intrude on the isolation band. The legs are in series with the isolators, so a more flexible leg structure would add a compliance that could degrade performance at higher frequencies even while leaving the 1.6 Hz and 1.2 Hz corners unchanged. If a project needs guaranteed isolation at a specific high frequency – above 50 Hz, say – ask for the current measured data for the exact height being ordered rather than assuming the two heights are interchangeable above the published points.

Series Comparison

The comparison that matters most for this frame is not against other sizes but against other isolation technologies, because the decision to buy an active frame at all comes before the decision about outline. The table below is the manufacturer comparison of active isolation against standard passive, heavy duty passive and rigid non-isolating supports.

Parameter Active Isolation Standard Passive Heavy Duty Passive Rigid, Non-Isolating
Vertical resonant frequency below 1.6 Hz 3.5 Hz 3.5 Hz Not applicable
Horizontal resonant frequency below 1.2 Hz Not applicable Not applicable Not applicable
Vertical transmissibility at resonance below 13 dB 24 dB 24 dB Not applicable
Horizontal transmissibility at resonance below 8 dB Not applicable Not applicable Not applicable
Vertical transmissibility at 10 Hz -34 dB -16 dB -16 dB Not applicable
Horizontal transmissibility at 10 Hz -34 dB Not applicable Not applicable Not applicable
Load capacity 700 kg (1,545 lbs) 24 to 260 kg (50 to 570 lbs) 135 to 700 kg (300 to 1,540 lbs) 700 kg (1,545 lbs)

Table 3. Isolation performance by support type, as published by the manufacturer. The active and passive systems are both compressed air systems; they differ in where the isolation starts.

Read the resonance rows together, because the numbers only make sense as a pair. A passive frame at its 3.5 Hz corner has a transmissibility of 24 dB, which is a factor of about 15.9 – the bench amplifies ground motion by nearly sixteen times at that frequency. An active frame at its corner has a transmissibility of below 13 dB vertically, a factor of about 4.5, and its corner is at 1.6 Hz rather than 3.5 Hz. So the active frame both amplifies less and amplifies at a frequency where there is less to amplify. The manufacturer states the practical consequence directly: the active system provides isolation above 2 Hz and the passive system only above 10 Hz. Everything between 2 and 10 Hz is the region where the two technologies are not comparable at all.

The load capacity column explains the rest of the market. A standard passive frame tops out at 260 kg, which rules out most laser systems on a bench of this size before isolation is even discussed. A heavy duty passive frame reaches 700 kg, the same as this one, so the choice between them is purely about frequency response and not about strength. A rigid non-isolating support also reaches 700 kg, and it is the right answer for a bench that only needs a flat, stiff, level surface – which is a genuine requirement for some assembly work and a false economy for anything with an interferometer on it.

Within the family, this outline sits between the 750 x 1200 mm frame and the 900 x 1500 mm frame. The table below sets out the six 800 mm outlines with the numbers that decide how much work each will take.

Model Breadboard Size Area (m2) Depth Operators Facing Each Other Clear Span Typical Use
PFA52509 750 x 750 mm 0.5625 750 mm One, from one side about 550 mm Single instrument
PFA52505 750 x 900 mm 0.6750 750 mm One, from one side about 700 mm One operator, short path
PFA52508 750 x 1200 mm 0.9000 750 mm One, from one side about 1000 mm One operator, long path
PFA52507 900 x 1200 mm 1.0800 900 mm Two, with 8 mm of slack each about 1000 mm Two operators, shared centre line
PFA52502 900 x 1500 mm 1.3500 900 mm Two, with 8 mm of slack each about 1300 mm Two operators, long path
PFA52504 1200 x 1500 mm 1.8000 1200 mm Two, with 158 mm of slack each about 1300 mm Multi-station, genuinely shared

Table 4. The six 800 mm outlines in the PFA range, with the depth-based operator count derived from a comfortable working reach of about 442 mm per operator.

The depth column is the one that separates this frame from its neighbours. Three of the six outlines are 750 mm deep and can only be worked from one side; two are 900 mm deep and can be worked from both sides, but only just; one is 1200 mm deep and can be genuinely shared. If a project needs two people at the bench and any equipment on the centre line, this outline is the cheapest way to get there but it is at the limit, and the 1200 mm deep frame is the comfortable answer.

Against the 700 mm version of the same outline, the comparison is unusually simple: the isolation specification, the load rating, the leveling repeatability, the air requirement and the breadboard compatibility are identical, and the difference in published list price is about 0.4 percent. That is small enough that the height decision can be made on working height and centre of gravity alone, with no cost argument in either direction.

FAQ

Does the 800 mm frame isolate less well than the 700 mm frame?

No. The manufacturer publishes a single specification table covering both heights, and every isolation figure in it is identical: below 1.6 Hz vertical, below 1.2 Hz horizontal, below 13 dB and below 8 dB at resonance, -18 dB at 5 Hz, -34 dB at 10 Hz, 700 kg capacity, ±0.25 mm leveling repeatability, 690 kPa air pressure. The isolators are the same components on both frames. The only difference is where the working surface ends up.

So what is the disadvantage of the taller frame?

The centre of gravity is 100 mm higher for the same payload, which reduces the margin against tipping by about 10 percent of the critical lateral force and about 2.4 degrees of critical tilt angle on a rigid body estimate. For a bench that stands still and is adjusted by hand, that margin is ample. For a bench that is pushed, leaned on, or rolled on casters, it is worth knowing about.

How much load can be placed on each isolator?

175 kg (386 lbs) when the total 700 kg is shared evenly across four isolators. That is the figure to check before bolting a heavy instrument into one corner. The self-leveling system compensates for an off centre load within its travel, but it cannot redistribute load, and an isolator driven past its stroke stops isolating without any obvious failure.

Is 900 mm deep enough for two people to work facing each other?

Just. Each operator gets 450 mm of depth, and the comfortable working reach of a 50th percentile operator standing 100 mm back from the edge is about 442 mm. That leaves 8 mm of slack, so both operators can reach their own half of the surface and neither can comfortably reach across the centre line. Anything that has to be shared needs to sit exactly on the centre line, or the bench needs to be 1200 mm deep.

What does -18 dB at 5 Hz mean in practical terms?

It means 12.6 percent of the ground motion at 5 Hz reaches the breadboard and 87.4 percent, quoted as 87.5 percent, is removed. That frequency band matters because foot traffic runs from 0.5 to 6 Hz, building pressure waves from 1 to 5 Hz and air compressors from 4 to 20 Hz. A passive frame with a 3.5 Hz corner cannot help below its own resonance, and at 3.5 Hz it amplifies by 24 dB.

Why does the horizontal specification matter as much as the vertical one?

Because a lateral shift of the breadboard moves a beam sideways, and a beam that moves sideways at the far end of a metre of path is a fringe shift or a coupling loss. The horizontal corner here is below 1.2 Hz with -34 dB at 10 Hz, which is the same attenuation as the vertical axis. On a long-path layout the horizontal figure is usually the one that limits performance, because the optical lever arm converts a small lateral motion into a large angular one.

What is the clear span along the 1200 mm axis?

About 1000 mm, after reserving 100 mm at each end for mounts and beam clearance. The 1500.0 mm diagonal of the outline is the number that governs how the frame is moved, and the 1000 mm span is the number that governs how much optical layout fits without an intermediate fold.

Can the frame be delivered assembled?

The frame is normally supplied as a frame with separate legs and is assembled on site, which is why the diagonal matters less than it would for a welded structure. Check the door width and the lift dimensions anyway: the breadboard is the item that usually will not fit, not the frame, and a 900 x 1200 mm breadboard is a heavy and awkward object to carry up a stairwell.

What air supply does it need?

690 kPa (100 psi) maximum, dry and oil free, supplied continuously at a flow rate sufficient to recover from a load change. Moisture and oil carry over will block the leveling valves and the damping orifices, and the symptom is a slow drift out of level rather than an obvious failure. With the air removed the breadboard rests securely on the frame and the isolation system is disabled.

What is the difference between the ±6 mm, ±10 mm and 26 mm figures?

The ±6 mm is the isolator travel, the ±10 mm is the travel of the leveling feet at the bottom of the legs, and the 26 mm (1.02 in) is the total height range of the assembled system. Only the last is useful for trimming the installed height, and none of them can substitute for the 100 mm difference between the two frame heights.

How much floor space does the frame need?

The frame occupies the breadboard footprint, so a 900 x 1200 mm bench needs about 900 x 1200 mm of floor plus access. Allow 600 mm on each working side so that two operators can stand without their backs against a wall, and 300 mm on the ends for access to the isolators and the air lines. That is roughly 2100 x 1800 mm of floor for a two-person station.

Usage Precautions

The precautions below are the ones specific to a bench of this size at this height. The theme is that the frame is soft by design and tall by choice, and both of those properties have consequences that are easy to forget once the bench is loaded and running.

  • Do not treat the 700 kg rating as a payload figure. It includes the breadboard, which for a 900 x 1200 mm by 60 mm Nexus board is on the order of 70 to 80 kg, and it assumes an even distribution. The usable payload after a 20 to 30 percent margin is roughly 400 to 480 kg.
  • Keep heavy items near the centre of the four isolators. An isolator that is driven past its stroke stops isolating quietly, and the first symptom is usually a mysterious loss of fringe contrast rather than an obvious mechanical problem.
  • Remember that the extra 100 mm of height costs about 10 percent of the tipping margin. Do not lean on the bench, do not climb on it, and do not use it as a support while moving something heavy past it.
  • If casters are fitted, move the frame empty or with the load clamped, never over a threshold or a cable duct, and never leave it standing on casters for a long campaign. The PWA061 set is rated 200 kg per caster and 800 kg for the four, which covers the 700 kg frame rating with about 14 percent in hand.
  • Supply dry, oil free air at no more than 690 kPa (100 psi). The leveling valves and damping orifices are small passages and they do not tolerate moisture or oil carry over.
  • Level the frame on its feet before pressurising, then pressurise and let the self-leveling settle before bolting anything down. Leveling a pressurised frame fights the valves and produces a slow oscillation that is hard to diagnose.
  • Allow the bench to settle after any significant load change. The valves restore position to ±0.25 mm, but the settling takes a few seconds, and a measurement started during that time will drift out of the data set.
  • Do not use the frame as a rigid datum while it is pressurised. A below 1.6 Hz vertical corner means the surface moves under a hand push; if a procedure needs rigidity, remove the air and let the breadboard rest on the frame.
  • Keep the rolling diaphragm at the base of each isolator clean. It is the one part of the mechanism that is sensitive to grit, and blowing dust around the isolator base with compressed air is the fastest way to shorten its life.
  • Check the floor before installation. A 700 kg frame on four feet is a substantial point load, and a raised access floor designed for a person and a trolley is not necessarily designed for 175 kg on a small pad. Spread the load with plates where the floor is suspect.
  • Do not assume the two operators can share the centre line. At 8 mm of slack the geometry is exact, so a shared sample holder has to be planned rather than discovered, and a shared item that is 30 mm off centre puts one operator outside their comfortable reach for the whole session.

One further point about the 1200 mm width. Each operator has about 884 mm of comfortable lateral coverage from a single stance, so the outer 158 mm at each end of the bench is outside the comfortable band. That strip should be reserved for items that are set once: a laser head, a fixed fold mirror, a beam dump, a power meter head that is read remotely. If a stage or a kinematic mount ends up there, the operator will be stretching for it all day and the layout will be blamed for a problem that is really a placement decision.

The last point is about the two frame heights being mixed in one laboratory. Because the isolation and the breadboard interface are identical, it is tempting to buy whichever height is available and mix them. The optical axes will then differ by 100 mm, which is not something the ±6 mm and ±10 mm adjustments can absorb and not something a breadboard change can absorb either. If a laboratory is going to end up with several of these frames, fix the height once and stay with it.

Disclaimer

The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and the manufacturer may revise specifications without notice.

The tipping table in the selection guide is a rigid body estimate, not a manufacturer load rating and not a test result. It assumes a base half-width of 450 mm, which is the breadboard half-width and therefore an optimistic upper bound on the real footprint of the frame; a smaller real footprint gives a smaller margin. It also ignores the compliance of the air springs, which is large and which means the practical limit is reached earlier, by lateral excursion of the suspension, than by rigid body tipping. Use the table to compare the two frame heights and to see how mass and centre of gravity interact, not to certify a load.

The static deflection and stiffness figures derived from the resonant frequencies are calculations from the published corners, not manufacturer data, and they assume a linear spring and a linear pendulum. The per-isolator load figure and the operator reach figures are likewise derived. Anthropometric values are taken as 50th percentile Chinese adults from GB/T 10000-1988, with a comfortable working reach of about 65 percent of maximum forward reach and a standing clearance of 100 mm from the bench edge; different populations or different assumptions will move the numbers.

No price is stated on this page. The percentage comparisons in the series comparison refer to published list prices for the two frame heights of the same outline and are given as percentages only, because list prices change with stock and currency. Availability, lead time and price are confirmed at the time of enquiry. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.

Contact Us

For a quotation on PFA52507, or for help deciding between the 900 mm and 1200 mm deep frames for a two-operator station, send the breadboard model and thickness, the mass and the height of the centre of gravity of the heaviest item, whether the bench will be used by one person or two, whether it will ever be moved on casters, and confirmation that a dry air supply at up to 690 kPa is available. Those five items settle the depth, the height and the loading question together.

For a project comparing this frame with a passive isolation frame of the same capacity, say so and include the lowest frequency at which the experiment is sensitive. The decision turns entirely on that number: above 10 Hz a passive frame will do, and below 2 Hz only an active frame will, with the whole band in between decided by how much margin the measurement needs.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PFA52507 Active Isolation Breadboard Support Frame, 800 mm Height, 900 x 1200 mm”

Your email address will not be published. Required fields are marked *

中文EN