Description
Product Overview
Work along a bench and the dimensions that matter turn out not to be the ones on the drawing. On a long narrow table the operator spends the session moving from one station to the next, and what decides whether that is quick or irritating is how far they have to reach across, not how far they have to walk. PFA52508 is the 800 mm frame for a 750 x 1200 mm (30 in x 48 in) breadboard – 0.9 m2 of surface on an outline 750 mm deep and 1200 mm long – carried on four independent air mounted active isolators rated 700 kg (1,545 lbs) in total. Its vibration figures are the family figures, since the isolators are the same parts on every frame: vertical corner below 1.6 Hz, horizontal corner below 1.2 Hz, below 13 dB and below 8 dB at resonance, -18 dB at 5 Hz with 87.5% of the ground motion removed, and -34 dB at 10 Hz with 98% removed. Leveling is pneumatic and self-acting to ±0.25 mm (0.010 in), the build is all steel in Black Paint, the air supply is 690 kPa (100 psi) maximum, and PWA061 casters are optional.
The proportions then decide the rest: a 1 to 1.6 rectangle with 3900 mm of perimeter, a 1415.1 mm diagonal, and 0.9 m2 of surface of which the operator can only ever touch part. The natural way to think about such a bench is that the length is the useful dimension and the width is a constraint. For optical layout that is right. For the person working at it, the opposite is true: the 750 mm depth is the binding constraint and the 1200 mm length only decides how many times they have to move.
The reason is reach. A 50th percentile adult has a maximum forward reach of about 834 mm, but a comfortable working reach of only about 65 percent of that, around 542 mm, and standing 100 mm back from the front edge costs another 100 mm. That leaves about 442 mm of comfortable working depth on a 750 mm deep bench, so the rear 308 mm is outside the comfortable band before anything else is considered. Along the length the numbers are much kinder: at a working depth of 300 mm the comfortable lateral coverage from one stance is about ±325 mm, so two stances cover the whole 1200 mm run. The bench needs two positions, not five.
The 800 mm frame changes the character of those two positions in a way that is easy to miss. With a 60 mm breadboard the working surface is at 860 mm, and a 50th percentile standing operator has a hip height of about 889 mm, so the surface is 29 mm below the hip. That is just enough for the operator to stand at the bench without their hip catching the edge, and just enough to lean forward about 16 degrees before the abdomen meets the front edge. On the 700 mm version the surface is at 760 mm, 129 mm below the hip, and the operator can lean 50 degrees or more – far more than the comfortable 15 degrees they would actually use.
So the difference between the two heights on this outline is not a difference in reach, it is a difference in working style. On the 700 mm frame the operator leans over the bench and slides along it, keeping their weight on the bench edge and their hands in the rear band. On the 800 mm frame they stand beside it and step along it, keeping their back straight and their hands in the front band. Neither is wrong, but they produce different layouts: the first puts adjustments at the back of the bench, the second puts them at the front and reserves the back for things that are set once.
There is a sharper version of the same point that matters when the breadboard is specified. With a 110 mm breadboard the surface on this frame rises to 910 mm, which is 21 mm above the hip height of a 50th percentile male operator. At that point the operator cannot lean over the bench at all – the hip presses the front edge and the torso tilts back – so the usable depth drops to the comfortable 442 mm and the rear 308 mm becomes genuinely out of reach. On a 750 mm deep bench, the combination of the 800 mm frame and the thickest breadboard is the worst case for rear-band access, and it is worth knowing before the order rather than after.
The sections below quantify the stance count, the lean, the cost of stepping along the bench and the zone structure that follows from all three. The isolation specification is identical to every other frame in the family and to the 700 mm version of this outline, so nothing in this page is about vibration performance; it is entirely about how a person works at a bench 750 mm deep and 1200 mm long.
Key Features
- A working surface between 825 and 910 mm, depending on whether the board fitted is 25 mm or 110 mm thick, with the optical axis following it to roughly 925 to 1060 mm above the floor – high enough that the operator works beside this bench rather than over it.
- The outline is 750 x 1200 mm (30 in x 48 in) at a 1 to 1.6 ratio, which gives 0.9 m2 of surface, 3900 mm of perimeter, a 1415.1 mm diagonal and about 1000 mm of clear span along the long axis.
- Depth is what limits this bench, not length: 750 mm is already at the edge of what one person can touch, about 734 mm from the front edge at full stretch, so the rear band behaves as a shelf.
- Comfortable working depth is about 442 mm, and that one figure decides which items may be made adjustable and which have to be set once and left alone.
- At any working depth up to about 300 mm, two stances cover the full 1200 mm run, so a sequence is worked from two positions roughly 600 mm apart instead of being walked end to end.
- With a 60 mm board the surface sits at 860 mm, only 29 mm under the hip of a 50th percentile standing operator, so the forward lean is available at its limit and not one degree beyond it.
- Corner frequencies are below 1.6 Hz vertically and below 1.2 Hz horizontally – the same parts and the same numbers as every other frame in the family, including the 700 mm version of this outline.
- Resonant transmissibility stays below 13 dB vertically and below 8 dB horizontally, against 24 dB for a standard passive frame, which at its corner multiplies motion by about 16 rather than reducing it.
- -18 dB at 5 Hz on both axes leaves 87.5% of the ground motion behind, and 5 Hz is exactly where footfall, building pressure waves and compressor pulses arrive on a normal floor.
- -34 dB at 10 Hz on both axes, 98% rejected and 18 dB better than a passive frame, which is the margin that keeps a metre-long beam path steady while the operator steps between the two stances.
- 700 kg (1,545 lbs) in total, 175 kg per isolator when evenly shared, against a 750 x 1200 mm by 60 mm breadboard of only about 60 to 70 kg, so the equipment budget stays generous.
- A dual chamber damped air spring carries the vertical axis and a trifilar pendulum the horizontal one, so a bench this long does not have to rock on a single shared setting.
- Pneumatic self-leveling holds ±0.25 mm (0.010 in) through precision three-way valves, which is what stops a 1200 mm run from tilting when the equipment is bunched at one end of it.
- ±6 mm at the isolators plus ±10 mm at the feet gives 26 mm (1.02 in) of total adjustment for trimming the installed height – useful against an uneven floor, useless for changing working height.
- 690 kPa (100 psi) of dry, oil free air is the requirement, and it is a continuous one: with the supply off the breadboard rests on the frame and the isolation is simply not there.
- All steel in Black Paint, so a 1200 mm run does not develop a thermal bow between a cold morning and a warm afternoon.
- PWA061 casters take 200 kg (440 lbs) each, 800 kg (1,760 lbs) for the four, which is enough to move the frame without taking the layout apart first.
- Four independent isolators re-level the bench after a heavy item has been carried from one end to the other, which on a long bench happens far more often than on a square one.
Technical Specifications
The rows below are the manufacturer data for PFA52508. The isolation rows repeat what every frame in the PFA range publishes, because the isolator hardware is shared across the family; the rows that are specific to this model are the 750 x 1200 mm breadboard size, the 800 mm frame height and the geometry that follows from a 1 to 1.6 outline.
| Specification | Value |
|---|---|
| Model | PFA52508 |
| Product class | Active isolation breadboard support frame |
| Breadboard size accepted | 750 x 1200 mm (30 in x 48 in) |
| Frame height | 800 mm (31.5 in) |
| Vertical resonant frequency | below 1.6 Hz |
| Horizontal resonant frequency | below 1.2 Hz |
| Vertical transmissibility at resonance | below 13 dB |
| Horizontal transmissibility at resonance | below 8 dB |
| Vertical transmissibility at 5 Hz | -18 dB (87.5% isolation) |
| Horizontal transmissibility at 5 Hz | -18 dB (87.5% isolation) |
| Vertical transmissibility at 10 Hz | -34 dB (98% isolation) |
| Horizontal transmissibility at 10 Hz | -34 dB (98% isolation) |
| Load capacity | 700 kg (1,545 lbs) |
| Load per isolator at rated capacity | 175 kg (386 lbs) when evenly shared |
| Isolators height adjustment range | ±6 mm (0.25 in) |
| Self leveling repeatability | ±0.25 mm (0.010 in) |
| Legs height adjustment range | ±10 mm (0.4 in) |
| Air pressure required | 690 kPa (100 psi) maximum |
| Finish | Black Paint |
| Construction | All steel |
| Isolator count and type | Four independent, air mounted, active vibration isolators |
| Leveling method | Pneumatic self-leveling, precision three-way valves |
| Optional casters | PWA061 (set of 4) |
| Largest breadboard supported by family | 1200 x 1800 mm (48 in x 72 in) |
| Outline area | 0.9000 m2 |
| Outline perimeter | 3900 mm |
| Outline diagonal | 1415.1 mm |
| Aspect ratio | 1 to 1.6, long axis 1200 mm |
| Clear span along the 1200 mm axis | about 1000 mm after 100 mm at each end for mounts |
Table 1. PFA52508 as published, with the outline geometry and the per-isolator load worked out from the stated breadboard size and capacity; the isolation rows are shared with the rest of the range.
The height rows are worth reading carefully because three numbers in this area are routinely confused. ±6 mm is the travel of the isolator bodies, ±10 mm is the travel of the leveling feet under the legs, and 26 mm (1.02 in) is the total height range of the assembled system. The manufacturer features text separately quotes leveling pads at ±9.5 mm (±0.375 in) and leveling feet at ±5 mm (±0.2 in), which describes different parts of the same region of the frame in different language; for selection the table above governs. On a bench this shallow, the figure that actually matters is none of those three but the surface height itself, because the surface height relative to the operator’s hip is what decides whether the rear band can be leaned into.
The percentages in brackets are isolation, not transmission, and inverting them is the commonest misreading of a specification sheet. -34 dB is a transmission factor of 0.0200: 2.0 percent of the ground motion arrives and 98 percent does not. -18 dB is 0.1259: 12.6 percent arrives and 87.4 percent is removed, quoted as 87.5 percent. The negative sign marks attenuation, so a bigger negative number and a bigger percentage say the same thing. For a task that depends on fringe stability, the useful way to read the pair is that the frame passes about one eighth of the ground motion at 5 Hz and about one fiftieth of it at 10 Hz.
Vertically the frame is a dual chamber, damped pneumatic spring: the breadboard is carried on air pressure in a chamber, sits on a piston, and the piston is sealed to the upper chamber by a rolling rubber diaphragm that makes vertical motion almost frictionless while blocking lateral motion. Floor movement pushes air through a high damping orifice from the lower chamber into the upper one, and that restriction is the damping. Without it the frame would be a very soft undamped spring and would ring for seconds after every disturbance.
Horizontally the frame is a trifilar suspension – three wires carrying the pneumatic isolators – so the restoring force after lateral displacement is gravitational, and oil free dampers between the bottom of each vertical isolator and the outer cylinder kill the oscillation at that corner. As equivalent static deflections, below 1.6 Hz is a spring compressing about 97 mm under its own load and below 1.2 Hz is a pendulum about 173 mm long; at 700 kg that implies about 70.7 kN/m vertically and 39.8 kN/m horizontally. Those are derived figures, and on a long narrow bench they are also the reason a rocking mode appears about the long axis above the horizontal corner: the trifilar resists translation, not rotation.
Leveling is by precision three-way valves actuated by the motion of the working surface. A tilt opens the appropriate valve, air is admitted or exhausted, and the surface returns to within ±0.25 mm of its previous level. On a 1200 mm long bench that is the difference between a layout that stays aligned for a month and one that needs realigning every time an item is moved from one end to the other.
The table below converts the frame height into a working surface height for the breadboards in normal use, and adds the hip clearance that decides whether the operator can lean over the bench. The hip clearance is the surface height subtracted from a 50th percentile standing hip height of about 889 mm.
| Breadboard fitted | Surface on this 800 mm frame | Hip clearance, 800 mm frame | Surface on the 700 mm version | Hip clearance, 700 mm frame |
|---|---|---|---|---|
| 25 mm aluminium board | 825 mm | +64 mm, lean available | 725 mm | +164 mm, lean available |
| 55 mm aluminium board | 855 mm | +34 mm, lean limited | 755 mm | +134 mm, lean available |
| 58 mm internally damped board | 858 mm | +31 mm, lean limited | 758 mm | +131 mm, lean available |
| 60 mm Nexus board | 860 mm | +29 mm, lean at its limit | 760 mm | +129 mm, lean available |
| 110 mm Nexus board | 910 mm | -21 mm, no lean possible | 810 mm | +79 mm, lean available |
Table 2. Surface height and hip clearance, calculated as the surface height subtracted from a 889 mm standing hip height. A negative hip clearance means the working surface is above the operator’s hip, so the front edge of the bench blocks any forward lean.
The last column of that table is the reason this page is about working style rather than about reach distances. On the 700 mm frame every breadboard thickness leaves at least 79 mm of hip clearance, which is enough for the operator to put their weight on the front edge and lean into the rear band. On this frame only the thin aluminium boards leave more than 34 mm, the standard 60 mm Nexus board is right at the limit, and the 110 mm board takes the surface above the hip and removes the lean entirely.
Applications
The applications below are the ones where a 1200 mm long, 750 mm deep bench at 800 mm does real work. Each of them involves a task sequence that runs along the length rather than spreading across a width, and each of them is affected by whether the operator leans or steps.
- Single-operator delay line and autocorrelator benches. A translation stage, a retroreflector and a detection arm laid out along the length, adjusted in sequence. The operator moves from the launch end to the delay end and back, which is exactly the flow this outline supports and exactly the flow that two stances cover.
- Fiber alignment and pigtail assembly. A launch stage at one end, a six-axis stage at the other, and a power meter in the middle. The task is a sequence of small adjustments at three points along a metre, and the operator’s movement between them is the dominant time cost once the alignment has converged.
- Laser diode characterisation and burn-in stations. A diode mount, a collimation stage, an attenuator and a detector in a line. These benches are worked standing, in short sessions, many times a day, which makes the working height matter more than the isolation bandwidth.
- Spectrometer and monochromator front ends. An entrance slit, a folding mirror and a grating arm want to be in line along the length, with the detector at the far end. The 1000 mm clear span along the 1200 mm axis takes the whole chain without an intermediate fold.
- Teaching benches with a fixed experiment sequence. Students work through steps placed along the length, and the bench has to tolerate being leaned on. The 700 mm version is often the better choice here for exactly that reason, and it is worth saying so.
- Probe and inspection stations with a long travel stage. A stage that travels 1200 mm needs a bench that is longer than its travel, and the operator follows the stage along the bench. The stance count and the zone structure below are the design constraints, not the load.
- Beam conditioning and delivery benches feeding a larger table. A sequence of telescopes, spatial filters and steering mirrors arranged along the length, aligned once and then left alone. This is the case where the rear band can be filled with static optics and the front band kept clear for the two or three adjustments that are made weekly.
Selection Guide
The selection question for this outline is not which frame to buy – that is decided by the same working-height argument as every other size – but how to lay the bench out so that one person can work it without walking the length twenty times an hour. That is a question about stance count, and stance count is arithmetic.
Start with the comfortable working reach. For a 50th percentile operator the maximum forward reach is about 834 mm and the comfortable working reach is about 65 percent of it, around 542 mm. Standing 100 mm back from the front edge costs 100 mm of that, leaving about 442 mm of comfortable depth and about 734 mm at full stretch. Now place a stance at the front edge and ask how much of the bench that stance covers at a given working depth. The lateral coverage is the square root of the reach squared minus the depth squared, so it falls away quickly as the working point moves back.
| Working depth from the front edge | Comfortable lateral coverage | Stances to cover 1200 mm at comfortable reach | Maximum lateral coverage | Stances to cover 1200 mm at full stretch |
|---|---|---|---|---|
| 0 mm | ±442 mm | 2 | ±734 mm | 1 |
| 100 mm | ±431 mm | 2 | ±727 mm | 1 |
| 200 mm | ±394 mm | 2 | ±706 mm | 1 |
| 300 mm | ±325 mm | 2 | ±670 mm | 1 |
| 350 mm | ±270 mm | 3 | ±645 mm | 1 |
| 400 mm | ±188 mm | 4 | ±615 mm | 1 |
| 450 mm | 0 mm | Beyond comfortable reach | ±580 mm | 2 |
| 500 mm | 0 mm | Beyond comfortable reach | ±537 mm | 2 |
| 600 mm | 0 mm | Beyond comfortable reach | ±423 mm | 2 |
| 750 mm | 0 mm | Beyond comfortable reach | 0 mm | Beyond full stretch |
Table 3. Lateral coverage from a single stance and the number of stances needed to cover the 1200 mm length, calculated from a 442 mm comfortable reach and a 734 mm maximum reach measured from the front edge. These are arithmetic, not manufacturer data.
The table gives the layout rule directly. If everything that has to be adjusted sits within the front 300 mm of depth, two stances cover the whole 1200 mm run and the bench is worked from two positions about 600 mm apart. If adjustments have to be made at 400 mm of depth, it takes four stances and the operator effectively walks the length. If they have to be made at 500 mm or deeper, they are outside comfortable reach from any stance and the task has to be redesigned – either by bringing the adjustment forward or by accepting that the operator will stretch for it every time.
The second half of the calculation is the lean, and this is where the 800 mm frame differs from the 700 mm one on this outline. Leaning forward over the front edge advances the shoulders, which extends the reach into the rear band. The advance is the torso length from hip to shoulder, about 478 mm, multiplied by the sine of the lean angle, so a 15 degree lean advances the shoulders by about 124 mm. Whether that lean is available depends on the hip clearance in Table 2. At 860 mm of surface the hip is 29 mm above the bench, which permits about 16 degrees of lean before the abdomen meets the edge – just enough to use the full 124 mm. At 910 mm the hip is below the bench and the lean is not available at all, so the rear band loses the 124 mm entirely.
Put together, the usable depth on this bench is about 566 mm with a 60 mm breadboard on either frame height, and about 442 mm with a 110 mm breadboard on the 800 mm frame. On a 750 mm deep bench that is the difference between the rear 184 mm being awkward and the rear 308 mm being out of reach. If the layout needs the rear band, specify the 60 mm board; if it needs a 110 mm board for stiffness, plan the layout to stay inside 442 mm.
The third part of the calculation is the cost of stepping along the bench, and it is larger than the walking time suggests. A 1200 mm traverse at a working pace of about 0.5 m/s takes 2.4 seconds. The re-orientation afterwards – finding the new hand position, re-establishing the visual reference, recovering the thread of the adjustment – takes an estimated 10 to 15 seconds. So each traverse costs about 14 seconds of which only 2.4 seconds is walking, and a session with twelve traverses loses nearly three minutes to movement alone. That is an estimate, not a measurement, but the ratio is the point: the walk is cheap and the interruption is expensive.
The practical consequence is that the bench should be organised into zones, one per stance, and each zone should be self-contained. A zone is about 600 mm of length and the front 300 mm of depth, and it should contain both the adjustment and the observation for one step of the procedure. A zone that requires the operator to adjust at one end and observe at the other is a zone that will be walked twelve times a session. The following sequence is the one that works:
- Divide the 1200 mm length into two 600 mm zones and draw a vertical line on the layout at 600 mm.
- Within each zone, put every adjustable item inside the front 300 mm of depth, where the comfortable lateral coverage is ±325 mm and two stances cover the length.
- Put every fixed item – laser head, beam dump, fixed fold mirror, detector that is read remotely – in the rear 300 to 750 mm band, where it will never need to be touched during a session.
- Keep both the adjustment and its indicator inside the same zone. If a beam has to be observed at one end while a mount is turned at the other, the task needs two people or a remote adjustment, not a longer reach.
- Check the deepest adjustment against Table 3. If it sits deeper than 300 mm, either move it forward or accept three or four stances and plan the session accordingly.
- Decide the breadboard thickness before the layout. A 110 mm board on this frame removes the lean and costs 124 mm of rear-band access, which is a layout decision disguised as a mechanical one.
- Confirm the air supply. 690 kPa (100 psi) maximum, dry and oil free, continuous, at a flow rate sufficient to recover from a load change.
One further point applies to any layout on a narrow bench. Because the depth is the binding constraint, the temptation is to use a 750 mm wide bench as if it were 750 mm of usable depth, and it is not. About 40 percent of the depth is behind the comfortable band on any of these frames. Treating the bench as 442 mm deep plus a shelf at the back is a more accurate mental model, and it produces layouts that are faster to work than layouts that assume the whole surface is available.
Series Comparison
Within the family, this outline is the longest of the three 750 mm deep frames and the one that trades width for length most aggressively. The table below sets out the six 800 mm outlines with the geometry that decides stance count and zone structure, which on a narrow bench is the dimension that matters.
| Model | Breadboard Size | Area (m2) | Depth | Length | Aspect Ratio | Typical Use |
|---|---|---|---|---|---|---|
| PFA52509 | 750 x 750 mm | 0.5625 | 750 mm | 750 mm | 1 to 1.0 | Single instrument, one stance |
| PFA52505 | 750 x 900 mm | 0.6750 | 750 mm | 900 mm | 1 to 1.2 | One operator, two stances |
| PFA52508 | 750 x 1200 mm | 0.9000 | 750 mm | 1200 mm | 1 to 1.6 | One operator, long sequence |
| PFA52507 | 900 x 1200 mm | 1.0800 | 900 mm | 1200 mm | 1 to 1.333 | Two operators facing each other |
| PFA52502 | 900 x 1500 mm | 1.3500 | 900 mm | 1500 mm | 1 to 1.667 | Two stations or one long path |
| PFA52504 | 1200 x 1500 mm | 1.8000 | 1200 mm | 1500 mm | 1 to 1.25 | Multi-station, genuinely shared |
Table 4. The six 800 mm outlines in the PFA range, with the depth and length that govern how many stances a single operator needs and whether a second operator can share the bench.
The aspect ratio column is the one that separates this frame from its neighbours. At 1 to 1.6 it is the most elongated outline in the family, and elongation is what makes a two-stance working pattern possible: a 750 x 750 mm bench of the same depth needs the same two stances for the same length of sequence, so the extra 450 mm of length is free in operator terms. That is the argument for this outline over the 750 x 900 mm one, and it has nothing to do with optics.
The same six outlines appear again below, this time with both heights side by side so that hip clearance can be read against price. The columns give the two model numbers, the surface under a 60 mm board, the hip clearance on each height, and the cost of the taller frame as a percentage.
| Breadboard Size | 700 mm Frame | 800 mm Frame | Surface with a 60 mm Board | Hip Clearance, 700 / 800 mm | Relative Cost of 800 mm |
|---|---|---|---|---|---|
| 750 x 750 mm | PFA51509 | PFA52509 | 760 mm against 860 mm | +129 / +29 mm | about 0.4 percent more |
| 750 x 900 mm | PFA51505 | PFA52505 | 760 mm against 860 mm | +129 / +29 mm | about 0.4 percent more |
| 750 x 1200 mm | PFA51508 | PFA52508 | 760 mm against 860 mm | +129 / +29 mm | about 0.4 percent more |
| 900 x 1200 mm | PFA51507 | PFA52507 | 760 mm against 860 mm | +129 / +29 mm | about 0.4 percent more |
| 900 x 1500 mm | PFA51502 | PFA52502 | 760 mm against 860 mm | +129 / +29 mm | about 4.2 percent more |
| 1200 x 1500 mm | PFA51504 | PFA52504 | 760 mm against 860 mm | +129 / +29 mm | about 4.2 percent more |
Table 5. Frame height pairing across the six outlines: surface height with a 60 mm board, hip clearance on each height, and the relative cost as a percentage only. Absolute prices are not published here.
On this outline the taller frame costs about 0.4 percent more than the shorter one, which is small enough that the decision should be made entirely on working height and working style. The hip clearance column shows the trade honestly: the 700 mm frame keeps 129 mm of clearance and therefore keeps the lean, while this frame keeps 29 mm and puts the lean right at its limit. If the layout needs the rear band, the shorter frame is easier to work. If the layout needs the working axis in the standing fine-work band, this one is.
Against PFA52505, the 750 x 900 mm frame, the difference is 300 mm of length for 0.225 m2 of area. In operator terms the extra length is nearly free: the stance count is the same two, the depth is the same 750 mm, and the only cost is that each stance has to cover 600 mm instead of 450 mm, which is well inside the ±442 mm comfortable coverage. That makes this outline the better buy for any sequence that has more than four steps.
Against PFA52507, the 900 x 1200 mm frame, the difference is depth rather than length. The 900 mm depth of that frame puts the far edge beyond reach entirely and makes it a two-operator bench; the 750 mm depth of this one keeps the far edge at full stretch and makes it a one-operator bench with a static rear band. If the work is a sequence rather than a collaboration, the narrow bench is faster.
FAQ
How many positions does an operator need along a 1200 mm bench?
Two, provided the adjustments sit within the front 300 mm of depth. At that depth the comfortable lateral coverage from one stance is about ±325 mm, so two stances 600 mm apart cover the whole run. If adjustments have to be made at 400 mm of depth the coverage falls to about ±188 mm and four stances are needed; deeper than 450 mm they are outside comfortable reach from any stance.
Can one person reach across a 750 mm deep bench?
At full stretch, just. The maximum forward reach of a 50th percentile operator is about 834 mm and standing 100 mm back from the edge leaves about 734 mm, against a 750 mm depth. So the far edge is at the very limit of maximum reach and well outside comfortable reach, which is about 442 mm from the edge. The rear band should be treated as a shelf, not as a working area.
Why does the 800 mm frame make the rear band harder to reach than the 700 mm frame?
Because it removes the lean. Leaning forward over the front edge advances the shoulders by about 124 mm at 15 degrees, which extends the usable depth. That lean requires the working surface to be below the operator’s hip, which is at about 889 mm. On this frame with a 60 mm board the surface is at 860 mm, leaving 29 mm of clearance and permitting about 16 degrees of lean – right at the limit. On the 700 mm frame the surface is at 760 mm, leaving 129 mm and permitting a comfortable lean.
What happens with a 110 mm breadboard on this frame?
The surface rises to 910 mm, which is 21 mm above the hip height of a 50th percentile male operator. At that point the front edge of the bench blocks any forward lean, so the usable depth falls to the comfortable 442 mm and the rear 308 mm of the bench is out of reach. If the layout needs the rear band, a 60 mm board is the better specification on this frame.
Is a taller frame awkward to walk along?
Not for the walking, but it changes the posture while you do it. With a 60 mm board the surface is at 860 mm and the hip of a 50th percentile standing operator is at about 889 mm, so 29 mm of clearance remains: enough to stand at the edge without the hip catching it, and enough for about 16 degrees of lean before the abdomen meets the front edge. The 700 mm version puts the same surface at 760 mm, leaves 129 mm and allows a lean of 50 degrees or more, which is far past the comfortable 15 degrees anyone actually uses. In practice the tall frame is worked by standing beside the bench with a straight back and keeping the hands in the front 442 mm, and the short frame is worked by leaning over the edge and sliding along it. The walking itself is unaffected; what changes is which band of the surface the hands can reach.
What does -18 dB at 5 Hz mean in percent?
It means 12.6 percent of the ground motion at 5 Hz reaches the breadboard and 87.4 percent, quoted as 87.5 percent, is removed. That band matters because foot traffic runs from 0.5 to 6 Hz, building pressure waves from 1 to 5 Hz and air compressors from 4 to 20 Hz, all of which a passive frame with a 3.5 Hz corner either passes or amplifies.
How much clear span does the 1200 mm length give?
About 1000 mm, after reserving 100 mm at each end for mounts and beam clearance. The 1415.1 mm diagonal is the number that governs how the frame and breadboard are moved, and the 1000 mm span is the number that governs how much layout fits without a fold.
What load can be placed on the bench?
700 kg (1,545 lbs) total, including the breadboard. A 750 x 1200 mm by 60 mm Nexus board is on the order of 60 to 70 kg, so the equipment budget is about 630 kg before margin and roughly 440 to 500 kg after a 20 to 30 percent margin. Per isolator the rated share is 175 kg when the load is evenly distributed.
Is the bench stable with a heavy item at one end?
The self-leveling system compensates for the height change and keeps the surface within ±0.25 mm, but it cannot redistribute load. An item heavy enough to drive one isolator past its stroke will cause that isolator to stop isolating without an obvious mechanical failure, and the symptom is usually a loss of fringe contrast rather than a visible problem. Keep heavy items near the centre of the four isolators, or check the per-isolator share first.
What air supply does it need?
690 kPa (100 psi) maximum, dry and oil free, supplied continuously. Moisture and oil carry over will block the leveling valves and the damping orifices, and the symptom is a slow drift out of level rather than an obvious failure. With the air removed the breadboard rests securely on the frame and the isolation system is disabled.
Can the bench be worked seated?
It can, but the geometry is not ideal. A seated operator’s elbow is at about 700 mm, so a 760 mm surface on the 700 mm frame suits seated fine work; an 860 mm surface on this frame is 100 mm higher than that. If the work is seated, the 700 mm version of this outline is the better choice, and the knee clearance under it is about 620 mm, which is enough for a chair at 420 to 450 mm.
Usage Precautions
These are the precautions that matter when a 750 x 1200 mm bench is worked along its length at 800 mm. They are mostly about posture and about where the mass sits, because the hardware on this outline is identical to every other frame in the family and the working method is what differs.
- Keep the mass centred along the 1200 mm rather than parked at one end. A 100 kg item at the far end loads two isolators and unloads the other two, and the self-leveling valves will restore height to within ±0.25 mm without doing anything whatever about the split; check the 175 kg per-isolator share before the item is bolted down.
- Choose the breadboard thickness before drawing the layout, not after. At 60 mm the surface is 29 mm below the hip and a 16 degree lean is there to be used; at 110 mm the surface is 21 mm above the hip, the front edge blocks the lean entirely and the rear 308 mm of the bench is out of reach. It is a layout decision that arrives disguised as a mechanical one.
- Do not lean on the bench while stepping between stations. The frame is soft by design – the vertical corner is below 1.6 Hz – so a hand on the surface applies a load that the leveling valves then chase for several seconds, and on a bench that is walked along that happens at every station of every session.
- Work from two positions about 600 mm apart rather than shuffling along the front edge. Two stances cover the run at any working depth up to about 300 mm; an operator who walks the length instead pays the re-orientation cost at every move, which is far larger than the 2.4 seconds the walk itself takes.
- Supply dry, oil free air at 690 kPa (100 psi) or less, continuously. The leveling valves and the damping orifices are small passages, oil and water reach them first, and the failure shows up as a slow drift out of level rather than as a fault anyone can see.
- Do not expect the height adjustment to settle the working height. ±6 mm at the isolators and ±10 mm at the feet give 26 mm (1.02 in) in total, which is a floor-trimming range; the 29 mm of hip clearance that governs the lean is set by the frame height and cannot be bought back with the feet.
One point about the narrow outline deserves separate mention. A bench 750 mm deep and 1200 mm long has a low frequency rocking mode about its long axis that a square bench does not, because the mass is distributed further from the centre in one direction. The manufacturer’s below 1.2 Hz horizontal figure covers the horizontal translation, and the rocking mode sits above it, but the practical consequence is that the two ends of a long bench move more than the centre under a lateral disturbance. If a measurement is made at one end, check whether the same measurement at the centre gives the same answer; that difference is the rocking mode.
The second point is about access. At 1415.1 mm the diagonal of this outline will not pass a standard 900 mm door, so the frame and the breadboard have to be brought in separately and assembled in the room. Confirm the route before ordering, and confirm it for the breadboard, which is the heavier and more awkward of the two items.
Disclaimer
The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and the manufacturer may revise specifications without notice.
The stance counts and lateral coverage figures in Table 3, the hip clearances in Table 2, the shoulder advance and usable depth figures, and the traverse cost estimates in the selection guide are calculations, not manufacturer data. They assume 50th percentile Chinese adult anthropometry as described in GB/T 10000-1988, with a maximum forward reach of about 834 mm, a comfortable working reach of about 65 percent of that, a standing hip height of about 889 mm, a hip to shoulder length of about 478 mm and an abdominal depth of about 100 mm, together with a standing clearance of 100 mm from the front edge of the bench. The traverse cost assumes a working pace of about 0.5 m/s and an estimated 10 to 15 seconds of re-orientation after each move. Different populations, different clothing and different tasks will move all of these numbers.
The static deflection and stiffness figures derived from the resonant frequencies are calculated from the published corners and assume a linear spring and a linear pendulum. The per-isolator load figure is derived from the rated capacity. Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the payload installed, its distribution along the bench, the floor and the quality of the air supply. No transmission curve for the isolation system is reproduced here; where a project requires a specific isolation performance at a specific frequency, request current performance data for the exact configuration.
No price is stated on this page. The percentage comparisons in the series comparison refer to published list prices for the two frame heights of the same outline and are given as percentages only, because list prices change with stock and currency. Availability, lead time and price are confirmed at the time of enquiry. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.
Contact Us
For a quotation on PFA52508, or for help laying out a 750 x 1200 mm bench so that one operator can work it without walking, send the layout sketch with the position of every item that gets adjusted during a session, the breadboard model and thickness, whether the operators will stand or sit, and confirmation that a dry air supply at up to 690 kPa is available. The positions of the adjustments decide the stance count, and the stance count decides whether this outline or the 900 x 1200 mm frame is the right one.
For a project comparing this frame with the 750 x 900 mm version, say so and include the number of steps in the procedure. Both have the same depth and therefore the same reach constraints, and the same two stances cover either length, so the choice turns on how many steps the procedure has rather than on the optics.









Reviews
There are no reviews yet.