Description
Product Overview
The Thorlabs LFE1220W-UK is a complete walk-in laminar flow enclosure around a 1.2 m x 2.0 m (4 ft x 6 ft) Nexus® optical table: a clean working area with 625 mm walkways at the table’s short edges and 525 mm at the long edges, so users can walk around the table to build and align large optical systems. The system – designed and built by Thorlabs’ UK subsidiary – includes the free-standing frame, soft transparent curtain walls, a closed ceiling, two top-mounted HEPA fan filter units (FFUs, 99.95% efficiency) and an air quality monitor (AQM). Castored legs let the enclosure be pushed as a whole; lower the feet to fix it. The frame does not touch the table, so vibration does not couple into it. Note: the optical table is purchased separately; on-site assembly is required (at least one step with four people) and no cables are supplied for the HEPA units. Tax-inclusive price $23,731.
Key Specifications
| Parameter | Value |
|---|---|
| Part number | LFE1220W-UK |
| Brand | Thorlabs |
| Type | Walk-in laminar flow enclosure (move around the table inside) |
| Compatible optical table | 1.2 m x 2.0 m (4 ft x 6 ft) Nexus® optical table (purchased separately) |
| HEPA fan filter units (FFU) | 2 units, top-mounted |
| HEPA efficiency | 99.95% |
| Air quality monitoring | Air quality monitor (AQM) included, continuous monitoring of the enclosure air |
| Interior size | 2100 mm x 3140 mm x 1920 mm (height to the bottom of the soft curtain walls) |
| Frame outline size | 3.29 m x 2.25 m x 2.40 m |
| Packing crate size | 3.25 m x 0.90 m x 0.85 m |
| Walkway space | 625 mm at the table’s short edges, 525 mm at the long edges |
| Max additional load | 300 kg (frame fixed on rubber feet; additional loads must not exceed 1600 N·m moment between any two feet) |
| Max load per rail | 100 kg (top boards must not carry heavy items) |
| Total weight | 270 kg |
| Foot height adjustment | -0 / +10 mm; castor at the base of each leg, fixed by lowering the feet |
| Input voltage | 230 V |
| Plug type | UK plug |
| Lighting included | 1 LED strip light (extra lamps via PSY240E) |
| Compatible accessories | Strip curtains (LFELSC8/14/21), overhead shelf (LFES1) |
| Installation requirements | On-site assembly; at least one step needs four people; no cables supplied for the HEPA units – wire to the local regulations |
Key Features
- Walk-in laminar flow enclosure – move around the table inside (625 mm / 525 mm walkways)
- 2 top-mounted HEPA fan filter units (FFUs), 99.95% efficiency
- Air quality monitor (AQM) included, continuously monitoring the enclosure air
- Castored legs for moving; fix by lowering the feet; feet adjust -0 / +10 mm
- Interior 2100 x 3140 x 1920 mm, 300 kg max additional load
- LED strip light included (extra lamps via PSY240E); strip curtain walls optional
Selection Guidance
The walk-in version suits long optical paths and long alignment campaigns – choose it when you work inside; the compact LFE1220 saves space when you work from outside. Choose voltage by laboratory supply: 230 V for -EU/-UK, 115 V for -US. Verify the site first: frame 3.29 x 2.25 x 2.40 m, crate 3.25 x 0.90 x 0.85 m, 270 kg total – check door heights, lifts and floor loading, plus 300 mm above the HEPA units for maintenance. To move the enclosure, raise the rubber feet and remove all additional load from the frame first – the load limits in the moved state are explicitly specified by the manufacturer.
Frequently Asked Questions (FAQ)
A: The walk-in enclosure volume is nearly three times the compact one; a single FFU cannot maintain uniform laminar flow over the whole section. The official configuration uses 2 top FFUs together, keeping 99.95%-efficiency laminar coverage inside. Power capacity and filter maintenance are also counted per two units.
A: Each leg has a castor and the enclosure can be moved, but within the official load limits: with the rubber feet raised and the frame on castors (the moved state), no additional load is allowed; fixed (feet down), up to 300 kg. Fit the table first, then surround it with the enclosure – or unload before moving.
A: -EU/-UK are 230 V (EU/UK plugs), -US is 115 V (US plug). For a 230 V grid choose -EU or -UK; the plug standard differs from local sockets, so confirm the socket or have an electrician handle it. No cables are supplied for the HEPA units – wire to the local electrical code.
A: The standard soft curtain walls are not laser protection material. For lasers inside, the manufacturer offers LFELP6B / LFELP7B laser protection panels (for the LFE1220 frame) replacing the long/short-edge curtain walls; the walk-in version can also add LFELSC strip curtain walls. Check each panel’s protection levels against the actual laser parameters.
A: The price shown on this page is a tax-inclusive RMB reference price converted to USD. Stock and lead time are confirmed on enquiry; contact Changsha Soar Laser for a formal quotation.
Disclaimer
Product images on this page are official Thorlabs images. Specifications, kit contents and dimensions are taken from the manufacturer’s official documentation and are provided for selection reference only; the manufacturer’s latest data sheet prevails. Prices shown are tax-inclusive reference prices in RMB converted to USD; final pricing, stock and lead time are confirmed in our formal quotation. Changsha Soar Laser Equipment Co., Ltd. supplies Thorlabs products with selection and technical support.









Reviews