Spherical Sag Calculator

Spherical Sag Calculator

📐 Spherical Sag and Aspheric Calculator

Spherical Sag and Aspheric Calculator

Accurately calculates the sag of spherical, conic and general aspheric surfaces, compares the deviation from the paraxial approximation, quantifies the difference between aspheric and spherical surfaces, and assists optical testing and fabrication.

📐
Spherical sag
sag = R−√(R²−y²)
Exact value
Aspheric sag
c·y²/(1+√(1−(1+k)c²y²))
Conic term
General aspheric equation
sag = conic term + A₄y⁴ + A₆y⁶ + A₈y⁸ + A₁₀y¹⁰

📐 Spherical Sag and Aspheric Calculator

Enter the radial distance and radius of curvature to calculate the exact sag, paraxial approximation and aspheric deviation



mm

Incident height (half-height of the aperture)


mm

Positive = convex, negative = concave, R≠0


📊 Calculation results
📐 Exact sag
—
mm
📏 Exact sag
—
μm
📉 Paraxial approximation
—
mm
🔬 Deviation (vs paraxial)
—
nm

Formula details

A complete mathematical description of sag calculation, from spherical to aspheric surfaces

① Exact spherical sag
sag = R − √(R² − y²)
R: radius of curvature (mm);y: radial distance / incident height (mm). This formula is derived from the sphere equation z² + y² = R² and is valid for all y ≤ |R|. When y = |R| the surface is a hemisphere (sag = |R|).
② Paraxial approximation (small aperture)
sag ≈ y² / (2R)
When y ≪ R, the exact formula can be Taylor-expanded to its first term. Applicable condition: for y/R < 0.3 the error is < 1%. For large apertures or short focal lengths the deviation is significant and the exact formula must be used.
③ Conic surface equation
sag = c·y² / (1 + √(1 − (1+k)·c²·y²))
c = 1/R: curvature (mm⁻¹);k: conic constant. For k=0 it reduces to a sphere; k=−1 is a paraboloid; k<−1 a hyperboloid; −1<k<0 an ellipsoid (major axis); k>0 an ellipsoid (minor axis).
④ General aspheric equation
sag = conic term + A₄y⁴ + A₆y⁶ + A₈y⁸ + A₁₀y¹⁰
The higher-order terms A₄~A₁₀ are used to superimpose fine corrections on the conic surface. Note that the coefficients have different units: A₄ is mm⁻³, A₆ mm⁻⁵, A₈ mm⁻⁷ and A₁₀ mm⁻⁹. Their magnitudes are typically between 10⁻⁶ and 10⁻¹⁰.
⑤ Reference table of conic constant k
k value Surface type Typical application
k = 0 Sphere Ordinary lens
k = −1 Paraboloid Aplanatic mirror
k < −1 Hyperboloid Cassegrain system
−1 < k < 0 Ellipsoid (major axis) Ellipsoidal reflective light collection
k > 0 Ellipsoid (minor axis) Special light-collection systems
⑥ Engineering significance: sag and testing
Sag is the core parameter in optical surface figure testing. An interferometer measures the deviation of the actual surface from a reference sphere (i.e. Δsag), and the polishing allowance is also determined by the sag tolerance. Aspheric sag deviations are typically on the order of μm, whereas spherical fabrication accuracy can reach λ/10 ≈ 50 nm.

Parameter details

Three key parameters affecting sag calculation

📏

Radius of curvature R

  • Distance from the vertex of the spherical surface to the centre of curvature (mm)
  • Positive sign = convex (centre of curvature behind the surface), negative sign = concave
  • The smaller R, the greater the curvature → the larger the sag
  • As R → ∞ the surface approaches a plane and the sag tends to 0
  • Industrial lenses commonly use R = 10~500 mm
⭕

Radial distance y (aperture)

  • Perpendicular distance from the optical axis to the edge (mm)
  • Aperture = 2y, i.e. the optical clear diameter
  • Physical limit: y ≤ |R| (otherwise beyond the sphere)
  • At y = |R| the surface is a hemisphere, with sag = |R|
  • The larger y/R, the greater the paraxial approximation error
🔷

Conic constant k

  • Determines whether the surface is spherical, paraboloidal or hyperboloidal
  • k = 0: standard sphere
  • k = −1: paraboloid (eliminates spherical aberration)
  • k < −1: hyperboloid (Cassegrain telescope)
  • The higher-order aspheric coefficients A₄~A₁₀ superimpose fine corrections on the conic surface

📋 Quick reference of common spherical sag values

Spherical sag for different radii of curvature and apertures (unit: mm)

R (mm) \ y (mm) y = 5 y = 10 y = 12.5 Paraxial applicability condition
R = 25 0.5133 2.1690 3.6068 y/R < 0.15
R = 50 0.2513 1.0102 1.5877 y/R < 0.15
R = 100 0.1253 0.5013 0.7886 y/R < 0.2
R = 200 0.0625 0.2502 0.3911 y/R < 0.3

⚠️ Common misconceptions and cautions

Common points of confusion in sag calculation

Is the paraxial approximation accurate enough?

When y/R is large, the paraxial approximation error can reach tens of μm. For example, at y=10, R=50 the deviation reaches 10.2 μm, far exceeding the λ/4 surface figure requirement. Large-aperture systems must use the exact formula.

Does the sign of the radius of curvature R not matter?

The sign of R indicates a convex (R>0) or concave (R<0) surface. In ray tracing, the sign determines the direction in which rays are bent. If the sign is wrong, the sag result is the same (since R² removes the sign), but the cumulative effect in a multi-surface system is completely different.

Is a larger conic constant k always better?

k does not represent a higher or lower order but the surface type. The k=−1 paraboloid is a common special case for eliminating spherical aberration and is better than the k=0 sphere in many situations. The choice of k depends on the design goal, not on blindly pursuing a particular direction.

Do the higher-order coefficients A₄~A₁₀ have the same units?

No! A₄ is in mm⁻³, A₆ in mm⁻⁵, A₈ in mm⁻⁷ and A₁₀ in mm⁻⁹. Their typical magnitudes also differ (10⁻⁶~10⁻¹⁰), so be sure to pay attention to the units and orders of magnitude when entering them.

Can sag be measured directly with a micrometer?

It cannot be measured simply as the height difference from centre to edge. Sag is the height relative to a reference plane (usually the edge tangent plane) and requires a dedicated sag gauge or interferometer for measurement, with the definition of the reference plane taken into account.

Is the sag non-zero when R→∞?

R→∞ is the limiting case of a plane. From the formula: sag = y²/(2R) → 0. A plane is the limit of zero curvature, with sag identically zero. If you calculate a very large R but a non-zero sag, it means the aperture y is also very large.

💡 Common application scenarios

🔬
Optical surface testing / interferometer calibration
An interferometer measures the deviation of the actual surface from a reference sphere (Δsag), requiring accurate sag calculation to determine the reference surface and tolerance. Surface figure accuracy requirements reach λ/20 or even higher.
🏭
Aspheric mould fabrication
Single-point diamond turning of aspheric mirrors (such as paraboloidal reflectors) requires real-time compensation of sag deviation. The control system drives the tool path based on the theoretical sag curve, and fabrication accuracy depends on the precise aspheric equation.
👁️
Contact lenses / corneal topography
The human cornea is approximately aspheric (k ≈ −0.26), and contact lens base curve design must match the corneal sag curve. Corneal topographers measure the sag at different radial positions to reconstruct the surface shape.

📋 FAQ

Q: What exactly is sag?
Sag is the axial depth of an optical surface at radial distance y relative to the tangent plane at the vertex. Simply put, it is the height by which a spherical or aspheric surface curves in or bulges out. The unit is usually mm or μm.
Q: Do the spherical and conic formulas give the same result at k=0?
Yes. At k=0 the conic formula c·y²/(1+√(1−c²y²)) is mathematically equivalent to R−√(R²−y²). The two can be transformed into each other by rationalisation identities.
Q: Under what conditions is the paraxial approximation error less than 1%?
When y/R < 0.15 (i.e. y²/R² < 0.0225), the paraxial approximation error is about < 1%. For a lens with R=50 mm, y must be < 7.5 mm. Large-aperture lenses or short-focal-length systems generally do not meet this condition.
Q: Is the sag difference between a paraboloid (k=−1) and a sphere large?
At large apertures the difference is significant. For example, at y=12.5 mm, R=50 mm, Δsag ≈ 25.2 μm, far exceeding optical surface figure accuracy requirements (typically λ/4 ≈ 0.16 μm). This is why large-aperture mirrors must use a paraboloid rather than a sphere.