Description
Product Overview
Stand a chair at a bench and the frame height stops being a matter of preference, because the number that governs it is the space between the floor and the underside of the breadboard, and the operator has to get their thighs through that space. PFA52504 is the 800 mm frame for a 1200 x 1500 mm (48 in x 60 in) breadboard and the largest of the six 800 mm outlines, so on this model the clearance question and the size question arrive together. Under a 60 mm board the working surface lands at 860 mm; underneath it there is about 720 mm of clear height, against about 620 mm on the 700 mm version of the same outline. The frame carries 700 kg (1,545 lbs) on four independent air mounted active isolators whose behaviour does not depend on which height they are bolted into: vertical corner below 1.6 Hz, horizontal corner below 1.2 Hz, below 13 dB and below 8 dB at resonance, -18 dB on both axes at 5 Hz (87.5% of the ground motion removed) and -34 dB at 10 Hz (98% removed). Leveling is pneumatic and self-acting to ±0.25 mm (0.010 in), the frame is all steel in Black Paint, the air requirement is 690 kPa (100 psi) maximum, and the PWA061 caster set is optional.
The question this page has to answer is the one that gets asked about every large bench: is the 800 mm height worth having, or is it just a bigger number? The usual answer is that a big bench carries tall things – an inverted microscope, a vertical illuminator, a camera standing up on top of a port – and that tall things need a taller frame. That answer is right about the conclusion and wrong about the mechanism, and the difference matters because getting the mechanism wrong leads to the wrong frame.
A tall element above the breadboard does not care where the breadboard is. What it cares about is where its top ends up relative to the operator’s eye. Raise the frame by 100 mm and the top of the stack goes up by the same 100 mm, so the headroom between the top of the stack and the operator’s eye gets 100 mm worse, not better. On this frame with a 60 mm breadboard and a 750 mm stack, the top of the assembly lands at 1610 mm, which is 42 mm above the standing eye height of a 50th percentile male operator. On the 700 mm version the same stack lands at 1510 mm, which is 58 mm below it. By that measure the shorter frame is better.
The mechanism that actually makes the taller frame the right choice for tall elements is the clearance underneath. The frame is 800 mm high, so with the top rail taken into account there is roughly 720 mm of clear height between the floor and the underside of the breadboard, against roughly 620 mm on the 700 mm version. That 100 mm is what a water hose for a laser head, a chiller line for a cooled camera, a below-table beam path or a delay line mounted underneath actually needs. And it has a second, less obvious effect: the clearance under the bench sets how high a chair can be pushed under it, and the chair height sets the seated eye height, and the seated eye height is what a tall vertical element has to be looked into from.
That chain is worth stating in numbers because it is the whole argument. With 620 mm of clearance under a 700 mm frame and about 150 mm of thigh, the highest chair that fits is about 470 mm, which puts the seated eye at about 1220 mm. With 720 mm under this frame the chair can go to about 570 mm, which puts the seated eye at about 1320 mm. A hundred millimetres of clearance under the breadboard buys a hundred millimetres of seated eye height, and that is what a high viewing port needs. Nothing about the top of the bench changed.
The outline is the largest in the 800 mm range: 1.8 m2 of surface, 5400 mm of perimeter, a 1920.9 mm diagonal and a 1 to 1.25 aspect ratio, leaving about 1300 mm of clear span along the 1500 mm axis. At 1200 mm deep it is also the only outline in the family that two operators can genuinely share, because each gets 600 mm of depth against a comfortable working reach of about 442 mm, which leaves 158 mm of slack rather than the 8 mm that the 900 mm deep frames leave.
The rest of the page deals with the vertical budget above the breadboard, the vertical budget below it, and the seated geometry that connects the two. It also sets out the cases where the 700 mm version is enough, because on a bench with no vertical elements and no under-table routing there is no case for the extra height at all, and the 700 mm version is about 4.2 percent cheaper.
Key Features
- Frame height 800 mm (31.5 in), the tallest in the range, which is what puts the working surface anywhere from 825 to 910 mm once the breadboard thickness has been chosen.
- Clear height under the board comes out at about 720 mm here and about 620 mm on the 700 mm frame, and that 100 mm is the whole specification: it fixes both what can be routed underneath and the tallest chair that will slide under the bench.
- Measured across the frame, 1200 x 1500 mm (48 in x 60 in) comes to 1.8 m2 of working area inside a 5400 mm perimeter; corner to corner it is 1920.9 mm, and roughly 1300 mm of clear span survives along the 1500 mm axis once 100 mm is reserved at each end.
- Only this depth supports two operators at once: at 1200 mm each side of the centre line gets 600 mm against a comfortable reach of about 442 mm, so 158 mm of slack remains where the 900 mm deep frames leave 8 mm.
- Same isolator, same corner: below 1.6 Hz vertically and below 1.2 Hz horizontally, with nothing added to or subtracted from the figure for the extra 100 mm of height.
- At resonance the frame still passes below 13 dB vertically and below 8 dB horizontally, where a standard passive frame reaches 24 dB and therefore amplifies at its own corner instead of attenuating.
- Transmissibility is down to -18 dB on both axes by 5 Hz, so 87.5% of what the floor is doing at that frequency never reaches the surface – and 5 Hz is where a footstep lands.
- At 10 Hz both axes are down -34 dB, leaving 2% of the motion and putting the frame 18 dB below a passive one at the same frequency, which is the margin a long exposure needs.
- Of the 700 kg (1,545 lbs) total, a 1200 x 1500 mm by 60 mm breadboard already spends 150 to 200 kg, and no isolator sees more than 175 kg once the remainder is spread evenly.
- Vertically the spring is a dual chamber damped air column and horizontally it is a trifilar pendulum, which is why the two axes can carry separate corners on a table this large rather than one compromise setting.
- Self-leveling is pneumatic and acts through precision three-way valves to ±0.25 mm (0.010 in), the mechanism that keeps 1.8 m2 of surface flat when a heavy item arrives in one corner and nothing arrives in the other three.
- Travel is ±6 mm at the isolators and ±10 mm at the feet, 26 mm (1.02 in) in total for the assembled system; none of it will bridge the 100 mm step between two frames, and it was never intended to.
- The air specification is 690 kPa (100 psi) at most, dry, oil free and uninterrupted; cut it and the breadboard simply sits on the frame with no isolation at all.
- Construction is all steel in Black Paint, and a 700 kg load spread over 1.8 m2 does not deflect it by enough to matter between one day and the next.
- Optional PWA061 casters carry 200 kg (440 lbs) per wheel and 800 kg (1,760 lbs) for the set of four, on non marking polyurethane tyres with full swivel, for repositioning a loaded frame.
- Four isolators share the load, so a heavy instrument placed at one end is carried by the frame as a whole rather than by two isolators pushed past their stroke.
- The 1920.9 mm diagonal is not a drawing curiosity: it decides whether the bench can be got into the room in one piece, and on this outline it usually cannot.
Technical Specifications
The table collects the manufacturer data for PFA52504 in one place. Everything in the isolation half of it – the two corners, the two resonant transmissibilities, the figures at 5 Hz and at 10 Hz, the capacity, the leveling repeatability and the air pressure – is common to the whole PFA range because the isolators are common parts; only the breadboard size, the frame height and the outline geometry rows belong to this model alone.
| Specification | Value |
|---|---|
| Model | PFA52504 |
| Product class | Active isolation breadboard support frame |
| Breadboard size accepted | 1200 x 1500 mm (48 in x 60 in) |
| Frame height | 800 mm (31.5 in) |
| Vertical resonant frequency | below 1.6 Hz |
| Horizontal resonant frequency | below 1.2 Hz |
| Vertical transmissibility at resonance | below 13 dB |
| Horizontal transmissibility at resonance | below 8 dB |
| Vertical transmissibility at 5 Hz | -18 dB (87.5% isolation) |
| Horizontal transmissibility at 5 Hz | -18 dB (87.5% isolation) |
| Vertical transmissibility at 10 Hz | -34 dB (98% isolation) |
| Horizontal transmissibility at 10 Hz | -34 dB (98% isolation) |
| Load capacity | 700 kg (1,545 lbs) |
| Load per isolator at rated capacity | 175 kg (386 lbs) when evenly shared |
| Isolators height adjustment range | ±6 mm (0.25 in) |
| Self leveling repeatability | ±0.25 mm (0.010 in) |
| Legs height adjustment range | ±10 mm (0.4 in) |
| Air pressure required | 690 kPa (100 psi) maximum |
| Finish | Black Paint |
| Construction | All steel |
| Isolator count and type | Four independent, air mounted, active vibration isolators |
| Leveling method | Pneumatic self-leveling, precision three-way valves |
| Optional casters | PWA061 (set of 4) |
| Largest breadboard supported by family | 1200 x 1800 mm (48 in x 72 in) |
| Outline area | 1.8000 m2 |
| Outline perimeter | 5400 mm |
| Outline diagonal | 1920.9 mm |
| Aspect ratio | 1 to 1.25, long axis 1500 mm |
| Clear span along the 1500 mm axis | about 1300 mm after 100 mm at each end for mounts |
Table 1. The manufacturer data for PFA52504, followed by derived outline geometry and the load each of the four isolators carries at rated capacity.
The three height figures in the table are separate and are frequently conflated. ±6 mm is the isolator body travel, ±10 mm is the leveling foot travel at the bottom of each leg, and 26 mm (1.02 in) is the total range of the assembled system, which is the only one of the three useful for trimming an installed height. The manufacturer product description separately lists leveling pads at ±9.5 mm (±0.375 in) and leveling feet at ±5 mm (±0.2 in) in its features text, describing different parts in different language; for selection the specification table above governs. What none of them does is absorb a 100 mm difference between two frames.
The bracketed percentages are isolation percentages, not transmission percentages, and the distinction is easy to invert. -34 dB corresponds to a transmission factor of 0.0200, so 2.0 percent of the ground motion reaches the surface and 98 percent is rejected. -18 dB corresponds to 0.1259, so 12.6 percent reaches the surface and 87.4 percent is rejected, which the manufacturer quotes as 87.5 percent. A more negative decibel figure and a larger percentage therefore mean the same thing, and both mean better.
The vertical element of the isolation system is a dual chamber, damped pneumatic spring. Air pressure in a chamber carries the breadboard, the breadboard sits on a piston, and a rolling rubber diaphragm seals that piston to the upper chamber, which makes vertical travel almost frictionless while blocking lateral displacement. When the floor moves, air is forced through a high damping orifice from the lower chamber into the upper chamber; that flow is the damping, and it is what converts a very soft spring into a stable platform. The ratio of the two chamber volumes sets the balance between a low corner and a fast settle.
The horizontal element is a trifilar suspension, a three wire pendulum on which the pneumatic isolators stand. Because the restoring force after a lateral displacement is gravitational, the horizontal corner can be low without the frame behaving like a spring, and oil free dampers between the bottom of each vertical isolator and the outer cylinder suppress the oscillation there. As equivalent static deflections, below 1.6 Hz is about 97 mm of spring compression under its own load and below 1.2 Hz is a pendulum about 173 mm long, giving an implied stiffness at 700 kg of about 70.7 kN/m vertically and 39.8 kN/m horizontally. Those figures are derived rather than published, but they make the softness of the design concrete.
Leveling is done by precision three-way valves that are driven by movement of the working surface. A tilt opens a valve, air moves, and the surface comes back to within ±0.25 mm of where it was. This is the mechanism that makes a large bench usable at all: on 1.8 m2 of surface, equipment arriving at one corner would otherwise tilt the whole table, and instead the valves compensate continuously and the surface stays level to a quarter of a millimetre.
The table below turns the frame height into a working surface height for this outline, and then into the clearance underneath, which is the figure this page is really about.
| Breadboard fitted | Surface on this 800 mm frame | Surface on the 700 mm version | Clear height under the board, 800 mm frame | Clear height under the board, 700 mm frame |
|---|---|---|---|---|
| 25 mm aluminium board | 825 mm | 725 mm | about 720 mm | about 620 mm |
| 55 mm aluminium board | 855 mm | 755 mm | about 720 mm | about 620 mm |
| 58 mm internally damped board | 858 mm | 758 mm | about 720 mm | about 620 mm |
| 60 mm Nexus board | 860 mm | 760 mm | about 720 mm | about 620 mm |
| 110 mm Nexus board | 910 mm | 810 mm | about 720 mm | about 620 mm |
Table 2. Surface height and under-breadboard clearance, calculated from the frame height and the breadboard thickness, with an assumed 80 mm top rail depth. The under-board clearance does not change with breadboard thickness because the breadboard sits on top of the frame.
The next table is the one that settles the question of tall elements. It lists the height of a representative stack above the breadboard surface and compares where the top of that stack lands against a standing operator’s eye height, on both frame heights. The stack figures are typical rather than exhaustive, but the pattern does not depend on the exact numbers.
| Tallest element on the bench | Height above surface | Top of stack, 800 mm frame with 60 mm board | Top of stack, 700 mm frame with 60 mm board | Clearance to a 1568 mm standing eye height, 800 / 700 mm frame |
|---|---|---|---|---|
| Laser head, mounts and a translation stage | 200 mm | 1060 mm | 960 mm | +508 / +608 mm |
| Inverted microscope with eyepiece port | 400 mm | 1260 mm | 1160 mm | +308 / +408 mm |
| Microscope with camera and cable relief | 600 mm | 1460 mm | 1360 mm | +108 / +208 mm |
| Vertical illuminator plus camera plus cabling | 750 mm | 1610 mm | 1510 mm | -42 / +58 mm |
| Sample chamber or cryostat with top access | 900 mm | 1760 mm | 1660 mm | -192 / -92 mm |
Table 3. Position of the top of a representative assembly against standing eye height, calculated from frame height plus breadboard thickness plus stack height. A positive clearance means the top of the stack is below eye level; a negative value means the operator must look up or step back.
Read the last column carefully, because it is the reason the naive argument fails. On every row, the taller frame leaves less headroom, not more, and on the two tallest stacks it is the taller frame that puts the top of the assembly above eye level while the shorter one keeps it below. If the only consideration were looking at the top of a tall element from the side, the 700 mm frame would win every time. The case for 800 mm has to come from somewhere else, and it does: from underneath the breadboard, and from the seated geometry that the under-breadboard clearance controls.
Applications
The applications below are the ones where the 800 mm height earns its place on a bench this large. Each of them involves something that happens below the breadboard surface or at a viewing height that has to be reached from a chair, rather than something that simply stands tall on top.
- Inverted microscope stations with a camera port. An inverted microscope on a breadboard puts its eyepiece about 400 mm above the surface and the camera about 600 mm above it. The eyepiece has to be looked into from a seated position, so the constraint is the seated eye height, and the seated eye height is capped by how high the chair can go, which is capped by the clearance under the bench. This frame gives about 720 mm of clearance and therefore about 1320 mm of achievable seated eye height.
- Vertical epi-illumination and light sheet benches. A vertical illuminator housing is 250 to 350 mm tall and sits on top of the objective turret, and the beam has to be delivered into it from the side. The delivery optics sit low on the bench while the illuminator sits high, so the layout spans the full vertical range of the surface and the under-bench clearance is what leaves room for the fibre and the cooling lines that serve it.
- Cameras mounted vertically on a port. A scientific CMOS camera standing on top of a port is 120 to 200 mm tall on its own, and its water cooling lines leave from the back at a height that needs a bend radius. Below the breadboard, the same bench usually carries the chiller hoses, and those need 125 mm of vertical space for a 90 degree bend at a 4 times bend radius on a 25 mm bore hose.
- Below-table beam paths and under-mounted delay lines. Some layouts put a retroreflector or a delay stage underneath the breadboard to use the vertical space rather than the surface. That is only possible with clear height, and the difference between 620 mm and 720 mm is the difference between a compact stage fitting and not fitting.
- Long standing sessions on a multi-station bench. A 1.8 m2 bench is usually worked standing because there is too much of it to work seated. On this frame the optical axis lands at about 985 mm with a 60 mm board and a 125 mm mount, which is inside the standing fine-work band; on the 700 mm frame it lands at 885 mm, which is below it.
- Sample chambers, cryostats and environmental cells with top access. A chamber that has to be opened from above needs the operator’s hands above it and their eyes at the seal. The 800 mm frame does not solve that problem by itself, but it does raise the seal to a height where a standing operator can work on it without stooping, and it leaves the space underneath for the vacuum line and the cold finger.
- Whole-room or multi-station installations. At 1.8 m2 with 1200 mm of depth, this is the smallest outline in the family that two operators can share without negotiating over the centre line. Where a room is being fitted out with several benches, standardising on this outline and this height keeps every axis at the same level.
Selection Guide
There are three vertical budgets to check on a bench this size, and the frame height decision follows from which of them binds. They are the budget above the surface, the budget below it, and the seated geometry that connects them. Checking them in that order is what turns a vague preference for a taller bench into a decision that can be defended.
The first budget is above the surface, and it is the one that most buyers check first and misinterpret. The relevant quantity is not the height of the tallest element but the height of the top of the assembly relative to the operator’s eye. For a standing operator of 50th percentile Chinese adult anthropometry the eye height is about 1568 mm, and the headroom is that figure minus the frame height minus the breadboard thickness minus the stack height. On this frame with a 60 mm board the budget for the stack is 708 mm; on the 700 mm frame it is 808 mm. A stack of 750 mm therefore exceeds the budget on this frame by 42 mm and stays inside it on the other. If a bench carries a very tall assembly that has to be inspected from the side, this budget is the one that decides, and it points at 700 mm.
The second budget is below the surface, and it is the one that usually decides in practice. With the top rail taken into account there is about 720 mm of clear height under the breadboard on this frame against about 620 mm on the 700 mm version. What has to fit in that space is water and chiller hoses, vacuum lines, cable bundles, a below-table beam path, or a delay stage mounted underneath. A 25 mm bore water hose with a 4 times bend radius needs about 125 mm of vertical space for a 90 degree bend and about 200 mm for a 180 degree bend, so both frames can take one hose. The difference appears when there are several hoses crossing, when a hose has to pass over a lower cross member, or when a stage has to be mounted underneath.
The third budget is the seated one, and it is the reason the second budget matters more than it looks. A seated operator’s eye height is the seat height plus about 750 mm. The seat height is capped by the clearance under the bench, because the operator’s thighs have to go under it: with about 150 mm of thigh thickness, the highest seat that clears the bench is the under-bench clearance minus 150 mm. The table below works that through for both frame heights.
| Seat height | Top of thigh | Clearance under a 700 mm frame (620 mm) | Clearance under an 800 mm frame (720 mm) |
|---|---|---|---|
| 420 mm | 570 mm | 50 mm clear | 150 mm clear |
| 450 mm | 600 mm | 20 mm clear | 120 mm clear |
| 470 mm | 620 mm | 0 mm, knees touching | 100 mm clear |
| 500 mm | 650 mm | 30 mm of interference | 70 mm clear |
| 520 mm | 670 mm | 50 mm of interference | 50 mm clear |
| 550 mm | 700 mm | 80 mm of interference | 20 mm clear |
Table 4. Knee clearance against seat height, calculated as under-breadboard clearance minus seat height minus an assumed 150 mm thigh thickness. Negative values mean the operator cannot get their knees under the bench at that seat height.
The consequence is direct. On a 700 mm frame the chair is capped at about 470 mm, which caps the seated eye height at about 1220 mm. On this frame the chair can go to about 550 mm, which puts the seated eye at about 1300 mm. So 100 mm of clearance under the breadboard buys about 100 mm of seated eye height, and that is what a high viewing port needs. The 800 mm frame is not better for tall elements because it lifts the element; it is better because it lifts the operator.
There is one caution in the other direction, and it applies to the thicker breadboards. A standing operator of 50th percentile height has a hip height of about 889 mm. With a 60 mm board this frame puts the surface at 860 mm, which is 29 mm below the hip, so the operator can still stand close to the front edge. With a 110 mm board the surface is at 910 mm, which is 21 mm above the hip, and an operator whose hip is below the bench top has to stand back from it. On a 1200 mm deep bench that does not matter much, because the far half belongs to the operator on the other side anyway, but it is worth knowing before specifying the thickest board available.
The decision procedure that follows from the three budgets is short:
- List everything that will be under the breadboard. Hoses, chiller lines, vacuum lines, cable bundles, a below-table beam path, an under-mounted stage. If any of them needs more than about 600 mm of clear height, or if several of them have to cross, the 800 mm frame is required.
- List the viewing heights. If anything has to be looked into from a chair and its port is more than about 1100 mm above the surface, check the seated geometry: the chair has to reach the height, and the chair height is capped by the clearance under the bench.
- Check the stack against eye height only if the assembly is very tall and is inspected from the side. If the stack exceeds about 700 mm above the surface, the taller frame reduces headroom and the shorter one may be better.
- Decide whether the bench will be worked standing or seated. Standing work favours the 800 mm frame because the optical axis lands in the fine-work band; seated fine work at the surface favours the 700 mm frame because a 760 mm surface is close to seated elbow height.
- Settle the compressed air question early: 690 kPa (100 psi) is the ceiling, the air has to be dry and oil free, and the supply must be continuous with enough reserve to re-level 1.8 m2 after a load change.
- Confirm the access route for the breadboard, not just the frame. The 1920.9 mm diagonal of this outline will not pass a standard door, and a 1200 x 1500 mm breadboard is the heavier and more awkward of the two items.
The cases where the 700 mm version is enough are worth listing explicitly, because they are common and they save about 4.2 percent of the list price. If the bench carries only a laser head, mirror mounts and translation stages, with nothing standing more than about 250 mm above the surface, and if nothing has to be routed underneath it, and if the operator sits for the fine work or stands only briefly, then there is no vertical budget that the 700 mm frame fails. In that case the extra height buys nothing and costs both money and headroom.
Series Comparison
Within the family, this is the largest of the six 800 mm outlines and the only one that is deep enough for two operators to share without negotiation. The table below sets out all six with the numbers that decide how much layout and how many people each will take.
| Model | Breadboard Size | Area (m2) | Depth | Clear Span | Clear Height Under the Board | Typical Use |
|---|---|---|---|---|---|---|
| PFA52509 | 750 x 750 mm | 0.5625 | 750 mm | about 550 mm | about 720 mm | Single instrument |
| PFA52505 | 750 x 900 mm | 0.6750 | 750 mm | about 700 mm | about 720 mm | One operator, short path |
| PFA52508 | 750 x 1200 mm | 0.9000 | 750 mm | about 1000 mm | about 720 mm | One operator, long path |
| PFA52507 | 900 x 1200 mm | 1.0800 | 900 mm | about 1000 mm | about 720 mm | Two operators, shared centre line |
| PFA52502 | 900 x 1500 mm | 1.3500 | 900 mm | about 1300 mm | about 720 mm | Two stations or one long path |
| PFA52504 | 1200 x 1500 mm | 1.8000 | 1200 mm | about 1300 mm | about 720 mm | Multi-station, genuinely shared |
Table 5. The six 800 mm outlines in the PFA range. Area and clear span are calculated from the stated breadboard size; the clear height under the board is a property of the frame height and is therefore the same across the family.
The clear height column is the same on every row, which is the point: on the 800 mm frames the under-breadboard budget does not change with outline. A laboratory that has decided it needs 720 mm of clearance can choose any of the six outlines on optical grounds and keep the clearance. That is not true across the two frame heights, which is why the height decision has to be made before the outline decision rather than after it.
Once the outline is fixed, height is the only variable left, so the second table holds the outline and moves the frame: two model numbers per row, the surface each one produces under a 60 mm board, the clearance each one leaves beneath it, and what the taller frame adds to the price expressed as a percentage.
| Breadboard Size | 700 mm Frame | 800 mm Frame | Surface with a 60 mm Board | Clear Height Under the Board | Relative Cost of 800 mm |
|---|---|---|---|---|---|
| 750 x 750 mm | PFA51509 | PFA52509 | 760 mm against 860 mm | 620 mm against 720 mm | about 0.4 percent more |
| 750 x 900 mm | PFA51505 | PFA52505 | 760 mm against 860 mm | 620 mm against 720 mm | about 0.4 percent more |
| 750 x 1200 mm | PFA51508 | PFA52508 | 760 mm against 860 mm | 620 mm against 720 mm | about 0.4 percent more |
| 900 x 1200 mm | PFA51507 | PFA52507 | 760 mm against 860 mm | 620 mm against 720 mm | about 0.4 percent more |
| 900 x 1500 mm | PFA51502 | PFA52502 | 760 mm against 860 mm | 620 mm against 720 mm | about 4.2 percent more |
| 1200 x 1500 mm | PFA51504 | PFA52504 | 760 mm against 860 mm | 620 mm against 720 mm | about 4.2 percent more |
Table 6. Both frame heights for each of the six outlines, read as surface height with a 60 mm board, clear height below the board, and the price difference as a percentage only; no absolute price appears on this page.
Two things in that table are worth noting for this outline specifically. First, it is one of the two where the taller frame carries a real premium, about 4.2 percent rather than about 0.4 percent, so the height decision here is a decision with a price attached rather than a free choice. Second, the clearance under the board is the same 100 mm difference on every outline, so the premium buys the same thing regardless of size: a fixed 100 mm of vertical space underneath, not a percentage improvement.
Against PFA52502, the 900 x 1500 mm frame, the difference is depth: 1200 mm against 900 mm for the same 1500 mm length. On the 900 mm deep frame two operators get 450 mm each against a comfortable reach of about 442 mm, which is 8 mm of slack and effectively means nothing can be shared across the centre line. On this frame they get 600 mm each, which is 158 mm of slack and is the difference between a bench two people work at and a bench two people work near.
Against PFA51504, the 700 mm version of this same outline, the comparison is entirely vertical: identical isolation, identical load rating, identical breadboard interface, identical footprint, and a 100 mm difference in the surface, the axis and the clearance underneath. Everything in the selection guide above applies, and there is no optical argument for either height because the isolation specification is published once for both.
FAQ
Is 800 mm the right height for a bench this large?
It depends on what is under the breadboard and how the bench is worked, not on how large it is. The 800 mm frame gives about 720 mm of clear height underneath against about 620 mm on the 700 mm version, and it puts the optical axis at about 985 mm with a 60 mm board and a 125 mm mount, which is inside the standing fine-work band. If the bench has nothing underneath it, nothing standing tall on it, and a seated operator, the 700 mm version is enough and about 4.2 percent cheaper.
Does a taller frame give more headroom for tall elements?
No, it gives less. A tall element sits on the surface, so raising the frame by 100 mm raises the top of the element by 100 mm as well, and the headroom between the top and the operator’s eye shrinks by 100 mm. On this frame a 750 mm stack reaches 1610 mm, which is 42 mm above a standing eye height of 1568 mm; on the 700 mm version the same stack reaches 1510 mm, which is 58 mm below it. The case for the taller frame comes from the clearance underneath, not from the headroom above.
How does the clearance under the bench affect a seated operator?
It caps the chair height, because the operator’s thighs have to go under the bench. With about 150 mm of thigh thickness, the highest seat that clears the bench is the clearance minus 150 mm. On a 700 mm frame that caps the seat at about 470 mm and the seated eye at about 1220 mm; on this frame it allows about 550 mm and about 1300 mm. That is why a high viewing port needs the taller frame even though the port itself has moved up by the same amount.
Can a 110 mm breadboard be used on this frame?
Yes, and it gives a surface at 910 mm. Be aware that a standing operator of 50th percentile height has a hip at about 889 mm, so a 910 mm surface is above hip height and the operator has to stand back from the front edge rather than lean over it. With a 60 mm board the surface is at 860 mm, which is 29 mm below the hip and allows the operator to stand close.
Does the extra 100 mm make the largest outline less stable?
The isolation does not change; the stability does, and the second half is worth a number. Every isolation figure is published once for both heights and is identical – below 1.6 Hz vertical, below 1.2 Hz horizontal, below 13 dB and below 8 dB at resonance, -18 dB at 5 Hz, -34 dB at 10 Hz, 700 kg capacity, ±0.25 mm leveling repeatability, 690 kPa air – because the isolators are the same components on both frames. What the extra 100 mm does change is the height of the centre of gravity. Treating the four isolators as a 900 mm footprint and the combined centre of gravity of breadboard and load as about 180 mm above the top of the frame, the angle at which the assembly would tip falls from 27.08 degrees on the 700 mm frame to 24.66 degrees on this one, and the steady lateral force that would take it over falls from about 3512 N to about 3153 N. Both pairs of figures are estimates from a rigid body model and not manufacturer data, and they are not working loads: they are the reason a 700 kg bench on a 1200 x 1500 mm outline should not be climbed on, and the reason a heavy instrument belongs over an isolator rather than over the middle of an edge.
What does -34 dB at 10 Hz mean in percent?
It means 2.0 percent of the ground motion is transmitted and 98 percent is removed. The bracketed percentage is the isolation, not the transmission. At 5 Hz the figure is -18 dB, which is 12.6 percent transmitted and 87.4 percent removed, quoted as 87.5 percent.
How much can be put on a bench this size?
700 kg (1,545 lbs) total, including the breadboard. A 1200 x 1500 mm by 60 mm Nexus board is on the order of 150 to 200 kg, so the equipment budget is about 500 to 550 kg before margin and roughly 400 to 480 kg after a 20 to 30 percent margin. Per isolator the rated share is 175 kg when the load is evenly distributed, which is the figure to check before placing a heavy instrument in a corner.
Can two people work at this bench at the same time?
Yes, and this is the only outline in the family where that is comfortable. The 1200 mm depth gives each operator 600 mm against a comfortable working reach of about 442 mm, which leaves 158 mm of slack. The 900 mm deep frames give 450 mm each and only 8 mm of slack, which means nothing can be shared across the centre line.
What air supply does it need?
690 kPa (100 psi) maximum, dry and oil free, supplied continuously at a flow rate sufficient to recover from a load change on a bench of this size. Moisture and oil carry over will block the leveling valves and the damping orifices, and the symptom is a slow drift out of level rather than an obvious failure. With the air removed the breadboard rests securely on the frame and the isolation system is disabled.
Will the frame and breadboard fit through a standard door?
Not in one piece. The outline is 1920.9 mm corner to corner, more than twice the width of a 900 mm door, so the frame goes in as a frame and the breadboard goes in as a breadboard and the two are married in the room; a loading bay, a removable window or a goods lift is the alternative. Confirm the route before ordering, and confirm it for the breadboard, which is the heavier and more awkward of the two.
What is the difference between the ±6 mm, ±10 mm and 26 mm figures?
The ±6 mm is the isolator travel, the ±10 mm is the travel of the leveling feet at the bottom of the legs, and the 26 mm (1.02 in) is the total height range of the assembled system. Only the last is useful for trimming the installed height on site, and none of them substitutes for the 100 mm difference between the two frame heights.
How much floor does a 1200 x 1500 mm bench need?
About 1200 x 1500 mm for the frame itself, plus access. Allow 600 mm on the two long sides so that two operators can stand without their backs against a wall, and 300 mm at the ends for the isolators and the air lines, which gives roughly 2400 x 2100 mm of usable floor.
Usage Precautions
The list below is about what goes wrong on 1.8 m2 of surface at 800 mm, and most of it follows from the two properties that make this frame worth buying: the surface is deliberately soft, and the space underneath it is large enough to be filled within a week.
- Measure the route before the order, and measure it for the diagonal. At 1920.9 mm this outline will not pass a 900 mm door and will not go into a lift with a 1000 mm opening, so frame, breadboard and isolators have to travel separately and be assembled in the room. The same check applies to the loading bay and to the last corner before the door.
- Plan the mass over four corners and a centre, not along one long edge. On 1.8 m2 the temptation is to build the layout down one side, which leaves the two far isolators light and the two near ones carrying most of the weight; the 175 kg per-isolator share is reached long before the 700 kg total is.
- Expect the valves to work after a single heavy item goes on. A 100 kg instrument at one corner tilts the surface, the three-way valves admit air to the low side and the surface returns to within ±0.25 mm, but the correction takes a few seconds, and a measurement started inside that window will drift for the rest of the scan.
- Do not try to close a height step with the adjustment range. The 26 mm (1.02 in) of total travel exists to trim an installed height over an uneven floor, not to match this frame to a 700 mm frame standing beside it; the 100 mm between the two is a purchasing decision and cannot be recovered on site.
- Air is 690 kPa (100 psi) maximum, dry and oil free, and it must not be interrupted during a session. Water and oil carry over reach the leveling valves and the damping orifices before anything else does, and the symptom is a slow loss of level rather than a clear fault, which is why the filter deserves more attention than the regulator.
- Keep the rolling diaphragms at the foot of each isolator free of grit. They are the only part of the mechanism with a sliding seal, and blowing dust around the base with an air gun is the quickest way to shorten their life.
One point about this outline deserves separate mention because it is easy to get wrong on a large bench. The 1200 mm depth means the far edge is about 466 mm beyond the maximum forward reach of a standing operator working from the near side, so the bench is really two 600 mm deep benches sharing a frame. That is fine, and it is what the outline is for, but it means the layout has to be drawn in two halves. A single beam path that wanders across the full 1200 mm depth cannot be adjusted by one person, and the second operator will spend the session reaching for things on the other side rather than doing their own work.
The second point is about the 4.2 percent premium on this outline. Because it is one of the two sizes where the taller frame costs materially more, it is worth confirming the height decision before the order rather than after. The under-breadboard clearance is the test: measure the tallest thing that has to pass underneath, add 50 mm for a bend radius, and compare with 720 mm. If it fits in 620 mm, the 700 mm frame will do and the money is better spent on the breadboard.
Disclaimer
The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and the manufacturer may revise specifications without notice.
The under-breadboard clearances in Table 2, the stack positions in Table 3, the knee clearances in Table 4 and the seated eye heights in the selection guide are calculations, not manufacturer data. They assume an 80 mm top rail depth, a 150 mm thigh thickness, a seated eye height of 750 mm above the seat, and standing anthropometry for 50th percentile Chinese adults as described in GB/T 10000-1988, with a standing eye height of about 1568 mm and a hip height of about 889 mm. Different populations, different chairs and different frame rail depths will move the numbers, and they should be recalculated for a specific installation.
The static deflection and stiffness figures derived from the resonant frequencies are calculated from the published corners and assume a linear spring and a linear pendulum. The per-isolator load figure is derived from the rated capacity. Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the payload installed, its distribution, the floor and the quality of the air supply. No transmission curve for the isolation system is reproduced here; where a project requires a specific isolation performance at a specific frequency, request current performance data for the exact configuration.
No price is stated on this page. The percentage comparisons in the series comparison refer to published list prices for the two frame heights of the same outline and are given as percentages only, because list prices change with stock and currency. Availability, lead time and price are confirmed at the time of enquiry. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.
Contact Us
For a quotation on PFA52504, or for help deciding whether this bench needs the 800 mm height, send the breadboard model and thickness, a list of everything that will pass underneath the breadboard with the diameter of each hose or cable bundle, the height above the surface of the highest viewing port, whether the operators will be standing or seated, and confirmation that a dry air supply at up to 690 kPa is available. Those five items settle the height decision and the clearance question together.
For a project that is fitting out a room with several benches, say so and include the room plan and the beam heights at the boundaries between benches. Standardising on one outline and one height across an installation is much easier to do once than to retrofit, and it is the only reliable way to avoid a periscope between two benches later.








Reviews
There are no reviews yet.