Fibre Mode Solver Calculator
Enter the operating wavelength, core and cladding refractive indices and core radius to solve online the LPlm eigenmodes: normalised frequency V, numerical aperture NA, number of modes M, the normalised frequency u and attenuation parameter w for each mode, effective refractive index neff, propagation constant β, mode field radius and confinement factor Γ. Eight common fibre presets are built in (single-mode, multimode, few-mode, erbium-doped, ytterbium-doped).
V = 2πa·NA/λ , NA = √(n₁² − n₂²) , u² + w² = V²
Common fibre presets
Basic fibre parameters
Mode field distribution
Selected mode parameters
Export all modes
Mode cutoff spectrum
Key equations and principles
Normalised frequency V
V = k₀·a·NA = 2πa·NA / λ
V is the single key parameter describing the number of modes in a fibre. For V < 2.405 only the fundamental LP₀₁ mode is guided, i.e. a single-mode fibre; larger V means more modes.
Numerical aperture and relative refractive index difference
NA = √(n₁² − n₂²) , Δ = (n₁² − n₂²) / 2n₁²
NA determines the light-gathering ability and the number of modes of a fibre; Δ is a common specification parameter, about 0.4%~0.5% for standard single-mode fibre.
Mode count estimation
M ≈ V² / 2
An empirical formula valid for large V,including polarisation degeneracy, roughly 2~4 times the total number of LP modes (degeneracy increases with l). For small V the error is large; the ‘actual number of LP modes’ on the left should be used instead.
LP mode eigenvalue equation
u·Jl−1(u)/Jl(u) + w·Kl−1(w)/Kl(w) = 0
w = √(V² − u²)
w = √(V² − u²)
Obtained from the core field Jl(ur/a) and the cladding field Kl(wr/a) by continuity of the field and its derivative at r = a. For l = 0 it should be written u·J₁(u)/J₀(u) − w·K₁(w)/K₀(w) = 0.
Mode field distribution
r ≤ a: F(r) = Jl(ur/a)
r > a: F(r) = [Jl(u)/Kl(w)]·Kl(wr/a)
r > a: F(r) = [Jl(u)/Kl(w)]·Kl(wr/a)
l is the azimuthal index (circumferential order) and m the radial index. LP₀₁ is the fundamental mode, whose field decays monotonically inside the core and is maximum at the centre.
Mode cutoff V number
Vc(LPlm) = Jl−1, the m-th zero of
l = 0:Vc(LP₀₁) = 0,Vc(LP₀m) = the (m−1)-th zero of J₁
l = 0:Vc(LP₀₁) = 0,Vc(LP₀m) = the (m−1)-th zero of J₁
The mode is guided only when V > Vc (cutoff). Typical values: 2.405 for LP₁₁, 3.832 for LP₂₁ and LP₀₂, 5.136 for LP₃₁ and 5.520 for LP₁₂.
Single-mode cutoff wavelength
λc = 2πa·NA / 2.405
Single-mode only when λ > λc (cutoff). Shorter wavelengths give larger V, so all single-mode fibres have a long-wavelength cutoff: single-mode around 1550 nm, possibly two-mode around 1310 nm.
Mode ray angle α
sin α = NA·u / (V·n₁) = √(1 − (n_eff/n₁)²) ≈ √(2Δ)·u/V
The true angle between a mode ray and the reflected ray at the core–cladding interface, measured from the core axis (using n_eff in place of n₁ gives about a 0.3% difference). The u/V in the interface card isa dimensionless normalised parameter (0~1), not an angle; do not convert it to degrees and read it as a ray angle.
Effective refractive index and propagation constant
neff = √(n₁² − NA²·(u/V)²)
β = k₀·neff
β = k₀·neff
neffalways lies between n₂ and n₁ and decreases as the mode order increases. The mode angle θ = u/V is the angle between the mode ray and the axis.
Confinement factor Γ
Γ = ∫₀a F²r dr / ∫₀∞ F²r dr
The fraction of total power contained in the core. The closer Γ is to 1, the more the light is confined in the core and the better the resistance to bending and microbending. Higher-order modes have smaller Γ and are more affected by bending.
Mode field radius w_MFD
|F(rMFD)| = |F|peak / e
the radius at which the intensity falls to 1/e² of the peak, consistent with the ISO/IEC single-mode fibre mode field diameter (MFD = 2w_MFD). For multi-ring higher-order modes, take the first 1/e crossover of the main lobe.
Frequently asked questions (FAQ)
How can I tell whether a fibre is single-mode or multimode?
Simply compare V with 2.405: V < 2.405 means single-mode (only LP₀₁ is guided) and V ≥ 2.405 means multimode. The status bar at the top of this tool gives the judgement directly. A more practical approach is to also check the cutoff wavelength λc: single-mode operation only when the operating wavelength λ > λc (the cutoff).
Why are shorter wavelengths more likely to become multimode?
V = 2πa·NA/λ is inversely proportional to wavelength, so shorter wavelengths give larger V. Taking the standard single-mode fibre preset on this page (a = 4.15 µm, NA = 0.117) as an example: V = 1.97 at 1550 nm and V = 2.34 at 1310 nm, both below 2.405, so it remains single-mode; but at as short as 900 nm, V = 3.40 exceeds the threshold and LP₁₁ becomes guided, making it multimode. Hence all single-mode fibres have a long-wavelength cutoff: in this example λc ≈ 1273 nm, and only λ > λc is single-mode. This is why 1310 nm offers wider bandwidth (lower dispersion) while 1550 nm allows longer transmission distances.
LPlmHow are the subscripts read?
l is the azimuthal index (circumferential order, determining the number of field lobes around the circumference) and m is the radial index (determining the number of radial lobes). LP₀₁ is the fundamental mode; LP₁₁ is the lowest-order higher-order mode; LP₂₁ and LP₀₂ have the same cutoff V, both 3.832.
Why don’t the mode count and M ≈ V²/2 agree?
M ≈ V²/2 is only an empirical approximation valid for large V,including polarisation degeneracy, so it is about 2~4 times the total number of LP modes (degeneracy increases with order). The error is larger for small V: for example, at V = 2.34, V²/2 ≈ 2.7 while in reality there is only one mode, LP₀₁. Please use the ‘actual number of LP modes’, which is obtained precisely from the per-mode cutoff criterion; the two are shown side by side precisely to make this multiplicity obvious.
Why is the ‘reference mode count’ several times larger than the number of modes I counted?
Because M ≈ V²/2 includes degeneracy. Each LPlm (l ≥ 1) corresponds to four degenerate modes in an ideal circular fibre (2 azimuthal orientations × 2 polarisations), and degeneracy increases with l, while V²/2 is a total estimate that counts all degeneracy. Therefore a factor of 2~4 difference from the ‘actual number of LP modes’ is normal; the two are not on the same basis and cannot be compared directly.
Why is the mode field radius smaller for higher-order modes?
The mode field radius is defined as the radius where the main-lobe intensity falls to 1/e² of the peak. Higher-order modes have multiple radial lobes, and side lobes beyond the main lobe raise the local intensity again, so the first 1/e crossover encountered moving outward from the main-lobe peak is necessarily much smaller than for a single-mode fibre. This is a consequence of the definition itself, not a calculation error. The effect of side lobes can be judged together with the confinement factor Γ: a smaller Γ indicates that power is more spread outside the core.
What is the scope of applicability of this tool?
This tool uses scalar LP mode theory under the weakly guiding approximation and applies tostep-index, circularly symmetric fibres. For graded-index multimode fibre, elliptical/polarisation-maintaining fibre, non-circular cores or microstructured fibre, a vector or numerical mode solver (e.g. MODE, COMSOL) is required, and these results serve only as an order-of-magnitude reference. In addition, the weakly guiding approximation requires NA not to be too large: accuracy degrades markedly when V exceeds about 60.
Disclaimer
This calculator solves step-index circular fibre using scalar LP mode theory under the weakly guiding approximation; the results are for engineering estimation and teaching reference and cannot replace measurement. Every numerical quantity at the core of the calculation (V, NA, the mode eigenparameters u and w, effective refractive index, propagation constant, confinement factor Γ and mode field radius) has been cross-checked value by value against a 25-digit-precision mpmath reference implementation: the relative deviation of Bessel zeros is better than 3.4e-10, for u and w better than 1.6e-10, for n_eff better than 2.4e-13, and for Γ and mode field radius under typical fibre parameters better than 1e-4. Γ was additionally verified independently by direct numerical integration (exact agreement with the integrated values for 14 modes). For actual design and selection, please refer to the fibre manufacturer’s datasheet and measured data.