Core formulae and principles
Important note on the damage threshold (LIDT)
The LIDT assessment in this tool is only a numerical comparison and does not constitute a basis for material selection. The damage threshold of pulsed lasers depends strongly onpulse width, number of pulses, spot size and the surface condition of the material: at the ns scale the threshold often rises with √τ, while at the fs scale avalanche ionisation dominates and the behaviour is quite different. Always refer tothe LIDT data for the corresponding pulse width in the component / optics datasheetand allow a safety margin (typically taking one half to one third of the nominal value).
Worked examples
CW cutting: 50 W focused to a 20 µm spot
P = 50 W
w₀ = 20 µm(Gaussian)
- Spot area A = π·(20 µm)² = 1257 µm² = 1.257×10⁻⁵ cm².
- Average power density I_avg = 50 / (1.257×10⁻⁵) ≈ 3.98×10⁶ W/cm².
- On-axis Gaussian peak I_peak = 2·I_avg ≈ 7.96×10⁶ W/cm² (about 7.96 MW/cm²).
Pulsed marking: 1 mJ / 10 ns / 20 µm spot
E = 1 mJ
τ = 10 ns
w₀ = 20 µm(Gaussian)
- Peak power P_peak = 1×10⁻³ J / (10×10⁻⁹ s) = 1.0×10⁵ W = 100 kW.
- Average fluence F_avg = 1×10⁻³ / (1.257×10⁻⁵) ≈ 79.6 J/cm²; Gaussian peak F_peak ≈ 159 J/cm².
- At a repetition rate of 20 Hz, average power P_avg = 1×10⁻³ × 20 = 0.02 W.
Frequently asked questions (FAQ)
What is power density (irradiance)?
Power density is the optical power per unit area, in W/cm² or W/m², commonly called ‘irradiance’ in the laser field. It determines whether a material is heated, melted or ablated and is the key quantity in CW processing and damage assessment.
What is energy density (fluence)?
Fluence is the pulse energy distributed over unit area, in J/cm². It directly determines how strong the damage or modification caused by a single pulse is, and is a key parameter for pulsed lasers (marking, micromachining, LIDT testing).
Why is the peak power density of a Gaussian beam twice the average?
The Gaussian intensity distribution is I(r) = I₀·exp(−2r²/w₀²) and the total power P = ∫I dA = (π w₀²/2)·I₀, so the on-axis peak I₀ = 2P/(π w₀²) = 2·(P/A) = 2·I_avg. A top-hat beam has uniform intensity across its cross-section, so the peak equals the average and the factor is 1.
What is the 1/e² radius w₀, and how is the diameter calculated?
The 1/e² radius is the radius at which the intensity falls to 1/e² (about 13.5%) of its on-axis value and is the standard ‘spot radius’ of a Gaussian beam. The spot diameter d = 2w₀; some references use ‘beam width’ = 2w₀, so be careful to distinguish radius from diameter — they differ by a factor of 2 and areas by a factor of 4.
What is the difference between a top-hat beam and a Gaussian beam?
A top-hat beam has an approximately uniform intensity distribution across its cross-section and often a higher damage threshold (more uniform heating); a Gaussian beam is strong at the centre and weak at the edges, with an on-axis peak density twice the average, making local damage at the centre more likely. This tool uses the ‘Beam profile’ switch to change the factor k (Gaussian k = 2, top-hat k = 1).
How should the peak power P_peak = E / τ be understood?
The instantaneous power obtained by ‘compressing’ all of the pulse energy E into the time window of the pulse width τ. For example, a 1 mJ, 10 ns pulse has a peak power of 10⁻³ / 10⁻⁸ = 10⁵ W = 100 kW. The shorter the pulse, the higher the peak power and the stronger the nonlinear effects.
What parameters are needed to estimate the focal spot w₀?
If the input beam waist, lens focal length and position are known, the focused w₀ can be found by the ABCD / q method (limited by diffraction and M²: w₀,min ≈ M²λf/(πD)). In this tool, enter the already calculated or measured focal 1/e² radius directly in ‘Focal spot’; for spot estimation see this site’s Gaussian beam propagation calculator.
How is the damage threshold LIDT used, and why is pulse width important?
Compare the calculated density with the component’s datasheet LIDT: below the threshold is usually safe, while approaching or exceeding it implies a damage risk. Pulsed LIDT depends strongly on pulse width — at the ns scale it often rises with √τ, whereas at the fs scale multiphoton / avalanche ionisation takes over with different behaviour; always use the threshold for the corresponding pulse width and allow a margin.
Why can’t I use average power alone to assess damage?
Even at a very low average power, a pulsed laser can have an extremely high peak power density per pulse. For example, a 1 mJ, 10 ns pulse has an average power of only 0.02 W (20 Hz), yet its peak power density can reach the GW/cm² scale, enough to damage a coating. Pulsed damage must be assessed using fluence / peak power density rather than average power.
How can I remember the unit conversions (W/cm², J/cm², W/mm²)?
Since 1 cm = 10⁴ µm, 1 cm² = 10⁸ µm²; W/cm² and W/mm² differ by a factor of 100 (1 W/cm² = 0.01 W/mm²). Using cm² for area gives the smallest numerical density and is the most convenient for direct comparison with a datasheet LIDT, so this tool uses W/cm² and J/cm² as its primary units by default.