QQ: 859818709

Optical Material Refractive Index Library

Optical Material Refractive Index Library

Optical Material Refractive Index Library (Optical Material Refractive Index Library)
Search and compare the refractive indices of common optical materials (optical glasses, fluoride / oxide crystals, infrared crystals and polymers) at any wavelength: the built-in Sellmeier dispersion equation evaluates n(λ) point by point, giving refractive indices at key spectral lines, n_d and the Abbe number V_d, with support for comparing dispersion curves and looking up arbitrary wavelengths.
n²(λ) = 1 + Σᵢ Bᵢ·λ² / (λ² − Cᵢ) (Sellmeier dispersion equation, λ in µm)

Material library search and comparison

Search by name, chemical formula or category; click a card to view the refractive-index details and dispersion curve of that material, and add it to the comparison (up to 3 materials).

Overlay of n(λ) for the selected materials over 0.35–1.7 µm (visible–near-infrared); infrared materials (Ge/Si/ZnSe) are opaque in this range and are not plotted.
nm

Core formulae and principles

1
Sellmeier dispersion equation
n²(λ) = 1 + Σᵢ Bᵢλ²/(λ²−Cᵢ)
The three-term Sellmeier formula is the most widely used dispersion model for the refractive index of transparent media: given six coefficients (B₁, B₂, B₃, C₁, C₂, C₃) and a wavelength λ (in µm), the refractive index n(λ) at any wavelength can be calculated. The coefficients are obtained by fitting manufacturers’ measured data and are valid only within the material’s transparency range.
2
Central refractive index n_d
n_d = n(587.6 nm)
The refractive index at the d line (helium yellow, 587.6 nm), the basic nominal value in optical glass catalogues (datasheets). This library recalculates it from the Sellmeier equation at 587.6 nm, generally differing from the manufacturer’s stated value by ≤ 0.0005.
3
Abbe number V_d
V_d = (n_d−1)/(n_F−n_C)
n_F = n(486.1 nm), n_C = n(656.3 nm). A larger V_d means lower dispersion (crown glass) and a smaller V_d higher dispersion (flint glass). This library recalculates them from the same Sellmeier equation at the three Fraunhofer lines.
4
Group refractive index n_g (approximate)
n_g ≈ n − λ·dn/dλ
The group index describes the propagation speed of a pulse envelope and is used in fibre dispersion and pulse-width calculations. It can be obtained by numerical differentiation of n(λ); it is not listed directly in this library, but you can take the slope of the dispersion curve yourself.
5
Transparency range
λ_min < λ < λ_max
Each material is transparent only in a specific waveband: fused silica / sapphire extend into the deep UV, CaF₂ into the far UV, and Ge/Si/ZnSe only into the infrared. Outside this range the Sellmeier equation fails and the material is opaque, so this library returns ‘out of range’.
6
Birefringent materials (uniaxial crystals)
n_o ≠ n_e
Uniaxial crystals such as MgF₂, sapphire and quartz have two refractive indices (ordinary o-ray and extraordinary e-ray). This library uses the o-ray for MgF₂ and the o-ray for sapphire (see the notes for n_e); no e-ray Sellmeier coefficients are listed.

Common optical glass reference (n_d and V_d taken from manufacturers’ datasheets)

Grade Type n_d V_d Dispersive power 1/V_d Typical applications
N-BK7 (SCHOTT) Crown 1.51680 64.17 0.01558 General lenses and prisms
N-BK10 (SCHOTT) Crown 1.49782 66.95 0.01494 Low-dispersion elements
N-BAK4 (SCHOTT) Crown 1.56883 55.98 0.01786 Photographic objectives
LLF1 (SCHOTT) Flint 1.54814 45.75 0.02186 Achromatic components
F2 (SCHOTT) Flint 1.62004 36.37 0.02749 Achromatic flint elements
SF2 (SCHOTT) Flint 1.64769 33.85 0.02954 High-dispersion prisms
N-SF5 (SCHOTT) Flint 1.67270 32.25 0.03101 Dispersive elements
N-SF6 (SCHOTT) Flint 1.80518 25.36 0.03943 High-index flint
SF11 (SCHOTT) Flint 1.78472 25.77 0.03888 Strong dispersion, high refractive index
N-LASF9 (lanthanum flint) Flint 1.85025 32.17 0.03108 High-index, low-dispersion flint
Fused Silica Crown 1.45846 67.82 0.01475 UV / deep UV, laser optics
CaF₂ (calcium fluoride) Crystal 1.43385 95.10 0.01052 IR / UV windows
Sapphire (o-ray) Crystal 1.76817 72.30 0.01383 Wear-resistant windows (n_e≈1.760)
FK51A (SCHOTT) Crown 1.48749 84.47 0.01184 Apochromatic (APO) design
Note: the table above gives catalogue nominal values (glass-type materials), which should be self-consistent with the n_d / V_d recalculated from the Sellmeier equation in the ‘Material library’ above. The complete set of 547 glasses can be found in the catalogues of manufacturers such as SCHOTT / OHARA / CDGM.

Data sources and disclaimer

Data sources:The Sellmeier coefficients and refractive-index data in this library are compiled from authoritative public sourcesrefractiveindex.info (based on the original literature and manufacturers’ datasheets such as SCHOTT and CDGM). Refractive index varies with temperature, stress, doping and measurement conditions; the values in this library are design reference values at room temperature (about 20–25 ℃) under standard conditions.
Disclaimer:This tool is intended only for preliminary selection and teaching reference in optical design and does not replace manufacturers’ official specification sheets. For production or critical optical systems, refer to the latest measured values in the material manufacturer’s datasheet. Infrared materials (Ge/Si/ZnSe) are opaque in the visible and valid only within their transparency ranges; nominal values for polymers such as PMMA / polycarbonate are approximate and vary considerably with composition and temperature.

Frequently asked questions (FAQ)

What is the Sellmeier equation, and how does it calculate refractive index?

The Sellmeier equation is a commonly used empirical formula describing how the refractive index of a transparent medium varies with wavelength (dispersion): n²(λ) = 1 + Σᵢ Bᵢ·λ²/(λ² − Cᵢ), where λ is in micrometres (µm) and Bᵢ, Cᵢ are material-specific coefficients. Given these six coefficients, the refractive index n(λ) at any wavelength can be calculated. More comprehensive than a single refractive-index value, it forms the basis of material libraries in optical design software such as Zemax and Code V.

What are the refractive indices n_d, n_F and n_C?

These are the refractive indices of the material at three Fraunhofer lines: the d line (helium yellow, 587.6 nm), the F line (hydrogen blue, 486.1 nm) and the C line (hydrogen red, 656.3 nm). n_d is the principal nominal value in glass catalogues; together with n_F and n_C it gives the Abbe number V_d for assessing dispersion.

How is the Abbe number V_d obtained from the refractive indices?

V_d = (n_d − 1) / (n_F − n_C). A larger V_d means lower material dispersion (crown glass) and a smaller V_d higher dispersion (flint glass). This library recalculates n_d, n_F and n_C from the same Sellmeier equation at 587.6 / 486.1 / 656.3 nm and then derives V_d, generally differing from the manufacturer’s stated value by ≤ 0.05.

Why can I not look up a refractive index for some materials in the visible?

Ge (germanium), Si (silicon), ZnSe (zinc selenide) and similar materials are infrared materials, opaque in the visible; the Sellmeier equation is valid only within their respective infrared transparency ranges (e.g. about 1.8–23 µm for Ge). A lookup at a visible wavelength returns ‘out of range’. Please switch to the infrared waveband.

Why is only one refractive index given for sapphire and MgF₂?

They are uniaxial birefringent crystals with two refractive indices, for the ordinary (o-ray) and extraordinary (e-ray) rays. This library uses the o-ray for MgF₂ and the o-ray for sapphire (sapphire n_e≈1.760); no e-ray Sellmeier coefficients are listed. If you need the e-ray, consult the manufacturer’s birefringence data.

Are the refractive indices of polymers accurate?

The refractive indices of polymers such as PMMA (acrylic) and polycarbonate (PC) vary considerably with composition, temperature, batch and additives, and their dispersion cannot be described accurately by a simple Sellmeier equation. The values given here are common nominal values (marked ‘approximate’) for preliminary design estimates only; use measured values for final selection.

How do I use this library to compare materials?

Click ‘Add to comparison’ in a material card’s details (up to 3 materials) to overlay their n(λ) dispersion curves in the comparison area, allowing direct comparison of the refractive-index levels and dispersion slopes of different materials in the same waveband. It is normal for infrared materials to have no curve in the visible range.

Are the data sources reliable, and can they be used directly for production design?

The coefficients come from the authoritative public source refractiveindex.info (based on original literature and manufacturers’ catalogues). The values are design references at room temperature under standard conditions and vary with temperature, stress and so on. For production or critical systems, always use the latest measured values from the material manufacturer’s datasheet; this tool provides no guarantee.

中文EN