Description
Model Note
This model designation has changed from RFL-P60MX to RFL-P60MX-E. Raycus now designates this 60 W MOPA pulsed fiber laser uniformly as RFL-P60MX-E; quotations, contracts and technical documents should all refer to the new model RFL-P60MX-E. The specifications on this page follow Raycus’s official RFL-P60MX-E Pulsed Fiber Laser User Manual V1.0 (January 2026); the full manual is available in the Downloads section below.
Product Overview
The Raycus RFL-P60MX-E is a 60 W MOPA (Master Oscillator Power Amplifier) pulsed fiber laser: central wavelength 1064 ± 5 nm, average output power 60-64 W, pulse width selectable from 2-500 ns in 16 steps, repetition rate independently adjustable from 1-4000 kHz, beam quality M² ≤ 1.6, air cooled, 24 VDC supply, 239 × 165 × 75 mm housing and a 3 m armoured delivery cable.
The MOPA architecture separates seed pulse generation from power amplification, so pulse width and repetition rate do not constrain each other — the core advantage over Q-switched pulsed lasers. One unit can run narrow pulses at high repetition rates for fine marking and thin-film cutting, or wide pulses at low repetition rates for deep engraving and cleaning with high single-pulse energy. Typical processes include black marking of anodised aluminium, colour marking of stainless steel, cutting of FPC coverlay and PET film, and removal of oxide layers and weld spatter from metal surfaces.
Key Features
- 16 pulse widths covering 2-500 ns: 2, 4, 6, 9, 13, 20, 30, 45, 60, 80, 100, 150, 200, 250, 350 and 500 ns are available; pulse width is issued online via DB25 serial communication, so changing process does not require stopping the machine or swapping hardware.
- Wide 1-4000 kHz repetition range: the narrow pulse settings (2/4/6/9 ns) reach up to 4000 kHz for high-speed fine marking, while wide pulse settings lower the base frequency and raise single-pulse energy to a maximum of 2.0 mJ (500 ns @ 500 kHz).
- Beam quality M² ≤ 1.6, spot 6-8 mm: a small focal spot with uniform energy distribution gives better colour consistency in black marking of anodised aluminium and colour marking of stainless steel.
- Industrial standard control interface: DB25 parallel port (8-bit power code 0-255, emission, MO, frequency, red aiming beam, emergency stop, alarm) plus DB9 RS232, directly compatible with mainstream marking control cards.
- Air cooled and compact: 239 × 165 × 75 mm with dual rear-panel fans and forced air cooling — no chiller required, easy to embed in a marking machine or use standalone.
- Sealed all-fiber optical path: core components developed in-house by Raycus, sealed maintenance-free optics and an output isolator to reduce the risk of damage from back-reflected light.
Specifications
The data below is taken from Table 2 of Raycus’s official User Manual V1.0, measured at the default 200 ns pulse width.
| Category | Item | Specification |
|---|---|---|
| Optical | Operating mode | Pulsed |
| Optical | Average output power | 60-64 W (RR = 48 kHz, 1000 kHz, Pmax); 1-2 W (RR = 1 kHz) |
| Optical | Power adjustment range | 0-100% |
| Optical | Central wavelength | 1064 ± 5 nm |
| Optical | Spectral width | ≤ 10 nm |
| Optical | Power instability | ≤ 5% (after 5 h continuous, RR = 48 kHz, P = Pmax) |
| Optical | Pulse width | 2-500 ns (16 steps) |
| Optical | Pulse rise time | < 120 μs (0 → 90% Pmax) |
| Optical | Pulse fall time | < 50 μs (100% → 10% Pmax) |
| Optical | Repetition rate range | 1-4000 kHz |
| Optical | Beam diameter | 6-8 mm (RR = 48 kHz, P = Pmax) |
| Optical | Beam quality M² | ≤ 1.6 |
| Electrical | Input voltage | 24 ± 1 VDC |
| Electrical | Max. input power | 300 W |
| Mechanical | Dimensions | 239 × 165 × 75 mm |
| Mechanical | Delivery cable length | 3 m (armoured) |
| Mechanical | Cooling | Air cooling |
| Other | Operating temperature | 0-40 °C |
| Other | Storage temperature | -20 to 60 °C |
| Other | Storage humidity | ≤ 80% |
Pulse Width vs. Base Frequency and Single-Pulse Energy
Each pulse width has its own base frequency and maximum single-pulse energy (Table 3 of Manual V1.0). The base frequency is a power-reduction protection point: below it the laser automatically reduces output power to protect itself, and only above it is the full-power range available.
| Pulse width (ns) | Base frequency (kHz) | Max. frequency (kHz) | Max. single-pulse energy (mJ) |
|---|---|---|---|
| 2 | 1950 | 4000 | 0.03 |
| 4 | 1350 | 4000 | 0.04 |
| 6 | 850 | 4000 | 0.07 |
| 9 | 600 | 4000 | 0.10 |
| 13 | 360 | 3000 | 0.17 |
| 20 | 252 | 3000 | 0.23 |
| 30 | 187 | 3000 | 0.32 |
| 45 | 132 | 2000 | 0.45 |
| 60 | 115 | 2000 | 0.52 |
| 80 | 90 | 2000 | 0.67 |
| 100 | 80 | 1000 | 0.75 |
| 150 | 57 | 1000 | 1.00 |
| 200 | 48 | 1000 | 1.25 |
| 250 | 46 | 900 | 1.30 |
| 350 | 35 | 600 | 1.70 |
| 500 | 30 | 500 | 2.00 |
Control Interface
- DB25 parallel port (main control): pins 1-8 set power as an 8-bit code 0-255 (corresponding to 0-100% power); pin 18 is MO pre-emission; pin 19 is emission; pin 20 is the frequency signal (TTL, 1-4000 kHz); pin 22 is the red aiming beam; pin 23 is emergency stop; pins 11/12/16/21 are alarm outputs; pin 17 requires an external +5 V supply to report alarms correctly.
- DB9 serial port (RS232): pin 2 RX, pin 3 TX, pin 5 GND, for communication between the host computer and the laser.
- Timing essentials: allow about 10 s after power-up before control; do not re-power within 5 s of a 24 V power loss; MO (pin 18) must lead emission (pin 19) by at least 5 ms, otherwise the laser may be damaged; pulse-width changes must be issued at least 1 ms before the rising edge on pin 18.
- Power supply: 24 ± 1 VDC — brown lead positive, blue lead negative, yellow-green lead to protective earth; reliable grounding is mandatory.
Typical Applications
- Black marking of anodised aluminium: narrow pulses at high repetition rates create a dark mark in the oxide layer that does not fade or damage the substrate — used on 3C housings, nameplates and hardware.
- Colour marking of stainless steel: adjusting pulse width and repetition rate controls oxide film thickness, producing black, grey and multiple colour grades in a single pass.
- Film and coverlay cutting: precision cutting of FPC coverlay and PET film with smooth, low-burr edges.
- Precision cleaning: removal of oxide layers, coatings and weld spatter from metal surfaces without damaging the substrate when parameters are set correctly.
- Photovoltaics and electronics: solar cell scribing and precision marking of electronic components.
Selection Guide
The RFL-P60MX-E is the 60 W workhorse of the Raycus MX series, balancing throughput and single-pulse energy for volume black marking of anodised aluminium, colour marking and film cutting. For conventional metal marking only, the Q-switched RFL-P60QB offers better cost performance; for deeper engraving or higher removal rates, step up to the 70 W RFL-P70MX or the 100 W RFL-P100MX.
MOPA Series Comparison
| Parameter | P20MX | P30MX | P60MX-E | P70MX | P100MX |
|---|---|---|---|---|---|
| Rated power (W) | 20 | 30 | 60 | 70 | 100 |
| Pulse width (ns) | 2-500 | 2-500 | 2-500 | 10-350 | 10-350 |
| Beam quality M² | < 1.5 | < 1.5 | ≤ 1.6 | < 1.6 | < 1.6 |
| Cooling | Air | Air | Air | Air | Air |
This table lists only the main differences. Complete parameters for other models (frequency range, single-pulse energy, power consumption, dimensions) follow their respective official manuals.
FAQ
Q: Is the RFL-P60MX-E the same unit as the former RFL-P60MX?
A: Raycus now designates this 60 W MOPA model uniformly as RFL-P60MX-E. The specifications on this page follow the new official Manual V1.0; please use RFL-P60MX-E in purchasing and contracts, and refer to Raycus’s latest official documentation for any technical differences.
Q: Is 60 W the average or the peak power?
A: It is the average output power. At the default 200 ns pulse width and repetition rates of 48 kHz and above, the full-power range is 60-64 W; below the base frequency (for example 1 kHz) the laser automatically reduces power to 1-2 W to protect itself.
Q: Can pulse width and repetition rate be adjusted independently?
A: Yes. The 16 pulse widths (2-500 ns) and the repetition rate (1-4000 kHz) are set independently, but the maximum repetition rate is limited by the pulse-width setting — for example 1000 kHz maximum at 100 ns and above, and 500 kHz maximum at 500 ns.
Q: Is a water chiller required?
A: No. The unit is fully air cooled with dual rear-panel fans. Leave at least 10 cm of ventilation space in front of and behind the housing, and make sure cabinet fan airflow does not oppose the laser’s airflow.
Q: Can it connect directly to an existing marking machine?
A: Yes. The DB25 is a standard industrial parallel port compatible with mainstream marking control cards. When wiring, note that MO (pin 18) must lead emission (pin 19) by more than 5 ms, and pin 17 needs a +5 V supply to read alarm signals correctly.
Downloads
Raycus RFL-P60MX-E Pulsed Fiber Laser User Manual V1.0 (Chinese, 18 pages, PDF 1.1 MB)
Covers safety information, technical specifications, installation dimensions, DB25/DB9 interface definitions and timing, operating procedures, warranty and repair process.
Disclaimer
The technical specifications on this page follow Raycus’s official RFL-P60MX-E Pulsed Fiber Laser User Manual V1.0 (January 2026). Where differences exist, the manufacturer’s latest official documentation and the agreed contract prevail. Price and stock are subject to the live page display or confirmation by phone. This is a Class IV laser product; at 1060-1085 nm its output exceeds 60 W, so laser safety goggles for the corresponding wavelength must be worn during operation and alignment, and direct viewing of the output head or specular reflections is strictly prohibited.
Contact Us
For selection advice, a quotation or technical support, please contact Soar Laser:
- Sales hotline: +86 159-2722-0467
- Website: www.soar-laser.cn
- Brand website: www.raycuslaser.com









Reviews
There are no reviews yet.