The AM MODULE NEXT GEN is RAYLASE’s next-generation prefocusing scan module for metal additive manufacturing: the RL3-100 galvanometer deflects ±0.325 rad, with positioning accuracy below 2.0 µrad on the standard version and below 0.4 µrad on the high-performance version, meeting the high-precision requirements of layer-by-layer powder bed scanning. It accepts 2000 W single-mode or 3000 W multimode laser input, and 30 rad/s high-speed scanning raises build efficiency, while IP64 protection copes with the powder environment. The one-piece housing measures 284×150×393 mm and weighs about 15 kg, making it easy to integrate into a build chamber.
Key Features
- Prefocusing design: installed inside the build chamber for layer-by-layer scanning
- High-precision galvanometer: below 2.0 µrad, below 0.4 µrad on the high-performance version
- High power compatibility: 2000 W single-mode / 3000 W multimode
- High-speed scanning: 30 rad/s raises build efficiency
- IP64 protection: reliable operation in powder and gas atmospheres
Technical Specifications
| Brand | RAYLASE (Germany) |
|---|---|
| Model | AM MODULE NEXT GEN |
| Deflection | ±0.325 rad |
| Galvanometer | RL3-100 |
| Positioning accuracy | below 2.0 µrad (below 0.4 µrad on the high-performance version) |
| Scanning speed | 30 rad/s |
| Laser power | 2000 W single-mode / 3000 W multimode |
| Protection rating | IP64 |
| Dimensions | 284×150×393 mm |
| Weight | approx. 15 kg |
Applications
Metal 3D printing (SLM), powder bed fusion, additive manufacturing equipment OEM. It also suits comparable processes under similar working conditions; non-standard customisation and volume solutions can be discussed, and drawings or process requirements can be submitted for a detailed evaluation.
Selection Guide
- RAYLASE modules support control solutions such as RAYGUIDE and SP-ICE, so please confirm compatibility with your existing control system when configuring.
- For imported components we recommend discussing lead time and spare-part stock in advance; customers running continuous production should keep a backup galvanometer or power module to reduce downtime risk.
- Models in the same series differ in power, clear aperture, interfaces and functional modules; for volume purchasing or line integration you can request a sample trial and a solution evaluation.
- This item is original factory stock and ships with a packing list and warranty certificate; warranty and spare-part support are provided from the date of receipt as agreed, excluding consumables such as lenses and seals.
- This is the RAYLASE AM MODULE NEXT GEN additive manufacturing module; the key specifications are listed in the parameter table above. If you need higher power, a larger aperture or a different interface or focal length version, please contact us for a series comparison and an offer.
Usage Precautions
- Never look directly into the beam or specular reflections while the laser is running; mark the working area with warning signs and protective screening, and wear goggles rated for the matching wavelength.
- Use purified or deionised water in the water-cooling system and replace it regularly; if water temperature or flow alarms are triggered, stop the machine, investigate and only then restart.
- Electrical wiring and servicing must be carried out by a licensed electrician, with lockout and tagout before work; the equipment must be reliably earthed to prevent leakage and interference.
- Protect the unit from moisture and dust during transport and storage; before long-term shutdown, drain the water circuit, disconnect power and cover the unit against dust.
- Follow the manual for the flatness of the mounting surface and for the cooling conditions; inadequate heat dissipation will derate the power module.
- On receipt, check the model nameplate and the supplied accessory list first. If problems arise during installation or commissioning, contact Changsha Soar Laser technical support (hotline +86 159-2722-0467) for remote or on-site assistance.
FAQ
What is the difference between prefocusing and post-focusing?
A prefocusing module sits inside the chamber close to the powder bed, so the optical path is short, the spot is small and precision is high; post-focusing scans through the chamber window, which is more flexible but makes spot control harder.
Single-mode or multimode?
Single-mode offers high beam quality for fine features; multimode spreads the energy more widely, which benefits build efficiency. Choose according to your scan strategy.
How is powder contamination prevented?
IP64 protection combined with chamber atmosphere management is sufficient; simply check and clean the window and lenses at regular intervals.
Disclaimer
The specifications on this page are compiled from the manufacturer’s public information and existing documentation and are for selection reference only. Product specifications are subject to the actual unit, the factory inspection report and the manufacturer’s latest data sheet; appearance and configuration may change with production batch, so please confirm with us before ordering. Reproduction of the content of this page without written permission is prohibited.
Selection enquiries: Changsha Soar Laser Equipment Co., Ltd., hotline +86 159-2722-0467, www.soar-laser.cn, email 859818709@qq.com.









Reviews
There are no reviews yet.