Description
This is the 10-piece pack of the PF10-03-M01; the optic is identical to the single-unit version.
Product Overview
Each disc in the box is Ø25.4 mm of fused silica, 6.0 mm thick with a tolerance of plus or minus 0.2 mm, carrying a protected gold film: a gold layer with a dielectric overcoat, specified at 96 percent average reflectance from 800 nm to 20 µm and usable from normal incidence out to 45 degrees. The front face is figured to λ/10 at 633 nm with 40-20 scratch-dig, the rear face is fine ground, parallelism is held to 3 arcmin or better, and the clear aperture is 90 percent of the diameter, which works out to 22.9 mm. Every rear face is laser engraved with the item number.
Buying ten is a production decision, not a discount decision. A bench that three shifts share, that a process engineer visits and that a customer walks past will collect fingerprints. A technician who wipes the fold mirror after every job will eventually leave a sleeker mark than the one he removed. In both cases the optic is not worn out optically, it is contaminated, and the difference between a film you may clean and a film you may not is the difference between a five-minute wipe and a purchase order. Ten on the shelf turns a contamination event into a consumable event, which is a much cheaper category to be in.
The overcoat is not free. The manufacturer states plainly that the dielectric layer on protected gold introduces polarization changes that are difficult to quantify, and that it can induce absorption in the mid to far infrared. Neither effect appears in an average reflectance figure, because both depend on wavelength and on angle in a way that a single percentage cannot express. Where the polarization state has to arrive at the target unchanged, such as a polarizing interferometer, the output fold of a polarization-maintaining delivery fibre, or an ellipsometer, this is the wrong part; the unprotected PF10-03-M03 is the right one, and its handling restrictions are the price of that.
The other thing to understand before ordering ten is what the film does not cover. Gold below 800 nm reflects poorly, so any visible alignment laser sharing this fold will come back dim and, worse, will come back at an angle-dependent brightness that no datasheet describes. A 633 nm pilot beam aimed through a protected gold fold is a common and avoidable commissioning problem: the fold is fine for the working beam and useless for the beam you are trying to align with.
Key Features
- Ten matched optics, one part number: a single order covers every turning point on a machine, so no station ends up with a mirror from a different purchase and a different storage history
- Wipeable film: the dielectric overcoat is what allows a solvent wipe, and it is the single property that matters most on a line where several people handle the same optic
- 800 nm to 20 µm in one coating: fibre laser work at 1.06 µm, erbium and thulium bands, and carbon dioxide work at 10.6 µm all sit inside the band
- Flat to λ/10 at 633 nm: a reflected wavefront that will not spoil an interferometric measurement or a tight focus downstream
- 6.0 mm fused silica: a coefficient of thermal expansion near 0.55 parts per million per degree, so the figure survives a warm enclosure and a cold start
- Broad angular tolerance: specified from 0 to 45 degrees, which covers the usual 45 degree fold and the small steering offsets around it
- Engraved item number on the rear face: after the bag is opened and the ten are spread across a bench, an unmarked disc is an unknown disc; the engraving ends that
- 2 J/cm² pulsed rating at 1.064 µm: measured with 10 ns pulses at 10 Hz over a 1.000 mm spot, enough headroom for marking, trimming and most delivery paths below a kilowatt
Technical Specifications
| Model | PF10-03-M01-10 |
| Pack size | 10 pieces |
| Coating | Protected gold (gold film with dielectric overcoat) |
| Wavelength range | 800 nm – 20 µm |
| Average reflectance | Ravg over 96 percent across the full band |
| Angle of incidence | 0 to 45 degrees |
| Substrate | Fused silica |
| Diameter | Ø25.4 mm (1 inch) per optic |
| Diameter tolerance | +0.0 mm / -0.1 mm |
| Thickness | 6.0 mm (0.24 in) |
| Thickness tolerance | plus or minus 0.2 mm |
| Surface flatness | λ/10 at 633 nm, peak to valley |
| Surface quality | 40-20 scratch-dig |
| Parallelism | 3 arcmin or better |
| Clear aperture | 90 percent of diameter (Ø22.9 mm) |
| Rear surface | Fine ground, laser engraved with the item number |
| Damage threshold, pulsed | 2 J/cm² at 1.064 µm (10 ns, 10 Hz, 1.000 mm spot) |
| Damage threshold, CW | 500 W/cm at 1.070 µm (0.089 mm spot); 750 W/cm at 10.6 µm (0.339 mm spot) |
| Mounting | Standard Ø1 inch optic mounts and retaining rings |
| Source | Manufacturer published series specifications |
Applications
These are the situations where holding ten earns its shelf space. They are all procurement and uptime situations rather than optical-design situations, because the optical design question was settled when the coating was chosen.
- Multi-shift benches: when the same fold mirror is touched by three shifts, a spare within reach removes the argument about who contaminated it and the delay while somebody orders one
- Pilot lines and first-article builds: a new machine is commissioned with a known-good set, and any mirror that gets handled during commissioning is simply replaced rather than inspected
- Field service kits: a service engineer who arrives with a sealed pack can restore a beam path in an hour instead of quoting a two-week lead time
- OEM build kits: ten per machine build, kitted with the mounts, so the assembly cell never runs short mid-build
- Dusty processes: cutting, welding and engraving cells throw particulate at every optic in the enclosure, and a film that can be wiped is the only film that survives that
- Spare-part contracts: an agreed holding of ten is a support commitment a customer can see, and it is cheaper than expediting singles
Selection Guide
| Situation | What goes wrong with singles | Reasonable holding |
|---|---|---|
| One machine, two to four turning points | One contaminated optic stops the machine while a replacement is ordered | 4 to 6 pieces |
| A line of four to eight heads | Mirrors migrate between heads, and nobody can say which head has which optic | 10 to 16 pieces, one pack per two heads |
| A teaching lab shared by several groups | Every session ends with a fingerprint and no spare in the cupboard | 10 pieces, held by the lab manager |
| A service organisation | Each call-out carries a delivery risk on top of the repair risk | 10 pieces per van kit |
| An OEM building ten or more machines | Kitting from singles adds a purchase order per machine | One pack per machine build |
Series Comparison
All six round 25.4 mm metal coatings in this format, compared on the numbers that decide a replacement purchase: band, average reflectance, whether the film can be cleaned, and the pulsed rating.
| Pack item | Coating | Band | Ravg | Cleanable | Pulsed threshold |
|---|---|---|---|---|---|
| PF10-03-M01-10 | Protected gold | 800 nm – 20 µm | 96% | Yes | 2 J/cm² at 1.064 µm |
| PF10-03-M02-10 | MIR-enhanced gold | 2 – 20 µm | 98% | Yes | 0.1 J/cm² at 1.064 µm |
| PF10-03-M03-10 | Unprotected gold | 800 nm – 20 µm | 97% | No | 4 J/cm² at 10.6 µm |
| PF10-03-P01-10 | Protected silver | 450 nm – 20 µm | 97% / 95% | Yes | 3 J/cm² at 1.064 µm |
| PF10-03-G01-10 | Protected aluminium | 450 nm – 20 µm | 90% / 95% | Yes | 0.3 J/cm² at 1.064 µm |
| PF10-03-F01-10 | UV-enhanced aluminium | 250 – 450 nm | 90% | Yes | 0.3 J/cm² at 355 nm |
FAQ
Q: Why would anyone buy ten of one mirror?
A: Because the failure that actually happens is contamination, not wear, and contamination arrives in bursts. One spill, one shift change or one enthusiastic cleaner can take out three optics in an afternoon. Ten is roughly two years of that rate on a small line, and the cost of holding them is a shelf, not a capital project.
Q: Can these be cleaned on the line, and how?
A: Yes, within reason. Blow off loose dust with clean dry air or nitrogen first, then drag a solvent-moistened lens tissue once across the surface in one direction, no pressure, no circular motion. Do not scrub a dried droplet, and do not repeat the process daily; the overcoat is thin and a wiping habit wears through any protected film in the end.
Q: Is protected gold acceptable where polarization matters?
A: Not where it matters strictly. The overcoat introduces polarization changes that the manufacturer itself describes as difficult to quantify, and they vary with wavelength and angle. For a polarizing interferometer, an ellipsometer or the final fold of a polarization-maintaining fibre, specify the unprotected PF10-03-M03 and accept the handling rules instead.
Q: Do the ten arrive optically identical?
A: They meet the same specification and normally come from the same coating run, but the specification is a window, not a single value: 96 percent is an average, and individual parts differ slightly across the band. For a power budget that has to close tightly, measure the first article and treat that measurement as the number.
Q: How should ten coated optics be stored?
A: Separately, in the original cases or in slotted trays, never face to face and never loose in a bag. Two coated surfaces in contact will scratch each other under nothing more than their own weight. Keep the tray closed and dry, and let a cold pack come to room temperature before opening it in a humid room.
Q: Can I mix M01 and M03 on the same machine?
A: You can, but then write down which is which. The two look identical in a mount, and the difference only shows up as a slightly different power at the workpiece and a different cleaning rule. A label on the mount costs nothing and prevents an unprotected optic from being wiped by someone who was told that all the fold mirrors can be wiped.
Usage Precautions
- Inspect on receipt by eye and under oblique light only. Do not test-clean a new optic to see whether the coating is present; you will find out by removing it.
- Never stack the ten face to face, and never leave one resting coated side down on a bench, even for a moment, even on a lens tissue.
- Handle by the rim with gloves or finger cots. A fingerprint on gold is not a cosmetic issue; the oil etches into the film and the local reflectance never recovers fully.
- Use plastic-tipped or nylon retaining rings, and tighten only until the optic stops moving. A metal ring tightened onto a 6 mm disc puts a bend into a surface specified at λ/10.
- Keep the pack sealed until the machine is ready. A mirror that sits open in a workshop for three weeks collects the workshop.
- Record which serial position went to which fold point. Without that record, a power drop three months later cannot be attributed to a specific optic or a specific swap.
- Block or dump the rear scatter. The rear face is fine ground, so it scatters rather than forming a clean ghost, but the scatter still goes somewhere and that somewhere is usually the inside of an enclosure.
Disclaimer
Specifications on this page are compiled from the manufacturer published series tables and are offered for selection purposes only; the current official datasheet governs. Dimensions, coatings and markings may change without notice. Price and delivery are quoted separately by our sales desk.
Contact Us
Tell us the wavelength, the beam diameter at the optic, the incidence angle and the number of turning points on the machine, and we will confirm whether protected gold is the right film for the whole path or only for part of it. Bulk and project quantities are quoted individually.









Reviews
There are no reviews yet.