Description
Product Overview
PFA51509 is an active isolation breadboard support frame from Thorlabs, dimensioned for a 750 x 750 mm (30 in x 30 in) breadboard. The frame stands 700 mm (27.5 in) high, carries a rated load of 700 kg (1,545 lbs), and rests on four independent, air mounted, active vibration isolators. Leveling is pneumatic and self-acting, with a repeatability of ±0.25 mm (0.010 in). The vertical resonant frequency is below 1.6 Hz and the horizontal resonant frequency is below 1.2 Hz. The structure is all steel, height is trimmed with leveling pads that give ±9.5 mm (±0.375 in) and leveling feet that give ±5 mm (±0.2 in), and the optional PWA061 caster set makes the frame mobile. A continuous source of pressurised air is required for operation.
On this particular frame, the 700 kg rating is not the number that decides whether a bench works. Divide it by four and each isolator carries 175 kg (386 lbs) at rated load. A 750 x 750 mm breadboard is a single-operator bench: one laser, one microscope body, a handful of translation stages, a detector. Assembled payloads of that kind usually land between 100 kg and 250 kg, which leaves two thirds of the capacity unused. The question a buyer should ask about PFA51509 is therefore not whether it will hold the equipment. It will, with a wide margin.
The question worth asking is where the mass sits vertically. Pneumatic isolation is a spring, and a spring carrying a tall mass is a pendulum as much as it is a filter. The air chamber sets the stiffness; the geometry decides how that stiffness acts on a mass whose centre is far above the support plane. Thorlabs states the consequence plainly: systems with a high centre of gravity can experience stability problems on pneumatic isolators, particularly when the tabletop is narrow. At 750 mm square this is the narrowest tabletop in the family, so the warning applies here more sharply than anywhere else in the range. It is the one design constraint that a 750 mm bench imposes and a 1200 mm bench does not.
A second point is often mis-stated, and correcting it removes a false worry. A small, lightly loaded tabletop is not a badly isolated tabletop. The stiffness of an air spring is governed by the height and volume of the air column rather than by the mass resting on it, so the resonant frequency of a 120 kg bench and a 600 kg bench on the same isolators stays at the design points of below 1.6 Hz and below 1.2 Hz. What changes with load is the height of the air column, and that is exactly what the leveling valve manages. A light payload therefore costs nothing in isolation performance. What it does change is the ratio between the supported mass and the mass carried high above the support plane, and that ratio is a stability question, not a filtering question.
The arithmetic used throughout this page takes the 750 x 750 mm outline and an assumed 100 mm inset for the isolator centres, which places the four mounting points on a 550 mm square with a base area of 0.3025 m². The nominal tabletop area is 0.5625 m². Reserving a 120 x 120 mm keep-out at each corner for the isolator and leveling hardware leaves 0.5049 m² of unencumbered surface, or 89.8 percent of nominal; the largest fully clear rectangle between those keep-outs measures 510 x 510 mm, or 0.2601 m². Against that base, a 700 kg load corresponds to 6,867 N, and with the centre of gravity one metre above the floor the lateral force needed to reach static tipping is 1,888 N. Nobody leans on a bench with 1.9 kN, so toppling is not the failure mode. The failure mode is a rocking mode that the leveling valve chases, and it presents as a slow oscillation that refuses to settle.
That reframing is the purpose of this page. What follows gives the full specification, the load-sharing arithmetic for off-centre payloads, a practical method for estimating and then lowering the centre of gravity, and the applications in which a 750 mm square bench is the correct answer rather than a compromise.
Key Features
- Four independent, air mounted, active vibration isolators. Each carries a quarter of the load at rating, so a single failed isolator produces an obvious tilt rather than a silent loss of performance, and the pneumatic self-leveling corrects the remaining three within ±0.25 mm once the fault is cleared.
- Vertical resonant frequency below 1.6 Hz and horizontal resonant frequency below 1.2 Hz. These are the corner frequencies of the isolation band. Floor motion below them is followed; floor motion above them is attenuated, and the attenuation grows with frequency. Building sway, footfall, pump rotation and traffic all sit above the corner, which is why the corner frequency is the specification that decides what the bench can do.
- A dual chamber damped pneumatic spring in the vertical direction. The tabletop is supported by air pressure, and the piston is sealed to the upper chamber by a rolling rubber diaphragm, which allows near frictionless vertical travel while blocking horizontal motion. Movement forces air through a high damping orifice between the two chambers, so oscillation is damped and settling time is short. The volume ratio of the two chambers is chosen to give both a low resonant frequency and usable damping at the same time.
- A trifilar suspension system in the horizontal direction. The pneumatic vertical isolators sit on a three-wire pendulum, and gravity supplies the restoring force after a horizontal displacement. Oscillation at the horizontal resonant frequency is suppressed by an oil-free damping element that links the base of each vertical isolator to the outer housing, so no hydraulic fluid is involved.
- 700 kg (1,545 lbs) load capacity with 175 kg (386 lbs) per point at rating. On a 750 mm bench this is headroom rather than a limit: it absorbs granite plates, motorised stages and heavy mounts without approaching the rating, and it means the frame is never the reason a heavier component cannot be added later.
- Sturdy all-steel construction. Steel gives the frame the stiffness and the thermal mass that a metrology bench needs, keeps the mounting interface dimensionally stable when the room temperature drifts, and provides the mass that anchors the pendulum. Tubular aluminium would be lighter to move and worse to measure on.
- Height trimmed by two independent means. Leveling pads give ±9.5 mm (±0.375 in) of travel for setting the working height and for taking up floor slope; leveling feet give ±5 mm (±0.2 in) of finer adjustment for compensating an uneven floor locally. The 700 mm (27.5 in) frame height suits a seated operator at a standard lab chair, and an 800 mm (31.5 in) version of the same frame is available for standing work.
- Optional PWA061 caster set. A set of casters converts the frame into something that can be repositioned between experiments without dismantling the optical setup. Casters are for moving, not for measuring: the frame should stand on its pads or feet while data is taken.
- Operation from a continuous source of pressurised air. Any compressor that delivers clean, dry, regulated air at the pressure and flow stated in the installation manual will do, and Thorlabs supplies a matching compressor. If the air supply is interrupted, the tabletop settles onto its supports and the bench behaves as a rigid frame until pressure returns.
- Below 8 dB horizontal transmissibility at resonance and -18 dB at 5 Hz in that axis. A 750 mm square top carrying a tall stack has a high centre of gravity relative to its footprint, and on such a bench the horizontal figure decides whether the assembly stays put, not the vertical one.
- -34 dB at 10 Hz in both axes, 98 percent isolation, and a vertical peak bounded below 13 dB. The vertical column is the easier of the two to satisfy on a small frame; it is quoted here so that the horizontal column can be read against it rather than in isolation.
Technical Specifications
The table below lists the manufacturer specifications that apply to this model. Values are quoted as published for the PFA series and apply to all five sizes in the range; only the breadboard outline changes from one model to the next.
| Parameter | Value | Note |
|---|---|---|
| Ordering code for this frame | PFA51509 | Thorlabs catalogue number |
| Product class | Active isolation breadboard support frame | Support structure, not a breadboard |
| Breadboard size accepted | 750 x 750 mm (30 in x 30 in) | Square outline, four-point support |
| Frame height | 700 mm (27.5 in) | 800 mm (31.5 in) version also available |
| Load capacity | 700 kg (1,545 lbs) | Total, including breadboard and fixtures |
| Isolator configuration | Four, independent, air mounted, active | One at each corner |
| Leveling method | Pneumatic self-leveling | Three-way valve, no electronics |
| Leveling repeatability | ±0.25 mm (0.010 in) | Return to level after a disturbance |
| Vertical resonant frequency | below 1.6 Hz | Lower edge of the isolated band |
| Horizontal resonant frequency | below 1.2 Hz | Set by the trifilar suspension |
| Vertical transmissibility at resonance | below 13 dB | Peak at the corner |
| Horizontal transmissibility at resonance | below 8 dB | Lower peak of the two axes |
| Vertical transmissibility at 5 Hz | -18 dB (87.5%) | 87.5% removed at five hertz |
| Horizontal transmissibility at 5 Hz | -18 dB (87.5%) | Horizontal figure governs a narrow top |
| Vertical transmissibility at 10 Hz | -34 dB (98%) | 98% removed, 2% transmitted |
| Horizontal transmissibility at 10 Hz | -34 dB (98%) | Same in both axes at ten hertz |
| Vertical isolation element | Dual chamber, damped pneumatic spring | Rolling diaphragm, orifice damping |
| Horizontal isolation element | Trifilar suspension system | Gravity restoring force, oil-free damper |
| Structure | All-steel construction | Tubular steel, welded and painted |
| Finish | Black Paint | Painted tubular steel |
| Height adjustment, leveling pads | ±9.5 mm (±0.375 in) | For working height and floor slope |
| Height adjustment, leveling feet | ±5 mm (±0.2 in) | For local floor unevenness |
| Isolators height adjustment range | ±6 mm (0.25 in) | Travel inside the pneumatic element |
| Legs height adjustment range | ±10 mm (0.4 in) | Static trim, set at installation |
| Total height range of the system | 26 mm (1.02 in) | Isolators plus legs, breadboard travel |
| Optional mobility | PWA061, set of casters | Ordered separately |
| Air supply | Continuous pressurised air | Clean, dry, regulated; compressor available |
| Air pressure required | 690 kPa (100 psi) maximum | Upper limit at the frame inlet |
| Behaviour without air | Tabletop settles onto its supports | Rigid frame until pressure returns |
| Largest breadboard the frame family supports | 1200 x 1800 mm (48 in x 72 in) | Not applicable to this model |
Read the bracketed figures as isolation, not as transmission: -34 dB leaves about 2.0 percent of the floor motion, so 98 percent is removed, and -18 dB leaves about 12.6 percent, which is the 87.5 percent quoted by Thorlabs. On height, the Features list gives leveling pads at ±9.5 mm and leveling feet at ±5 mm, while the rows above give ±6 mm for the isolators and ±10 mm for the legs; the two pairs refer to different components, and the specification rows are the ones to select from. The 26 mm entry is the breadboard height range of the complete system, and the resonant frequencies are stated as limits, below 1.6 Hz and below 1.2 Hz.
The next table is not manufacturer data. It contains planning figures derived from the published outline and from the assumptions stated in the note column, and it exists because the numbers a laboratory actually needs when laying out a room are rarely the numbers printed on a specification sheet. Treat the derived values as a starting point for the site survey, and replace the assumptions with measured values wherever the project allows it.
| Derived Figure | Meaning | Basis |
|---|---|---|
| 0.5625 m² | Nominal tabletop area | 750 mm x 750 mm |
| 0.0576 m² | Four corner keep-outs | 4 x 120 mm x 120 mm, assumed |
| 0.5049 m² | Unencumbered surface | 89.8 percent of nominal |
| 510 x 510 mm | Largest fully clear rectangle | 0.2601 m² between keep-outs |
| 550 mm | Isolator centre spacing | Assumes 100 mm inset from each edge |
| 0.3025 m² | Base area of the four support points | 550 mm x 550 mm |
| 175 kg (386 lbs) | Load per isolator at rating | 700 kg divided by four |
| 6,867 N | Weight at rated load | 700 kg x 9.81 m/s² |
| 1,888 N | Lateral force for static tipping | Centre of gravity 1.0 m above floor |
| 490 to 560 kg | Payload budget at 20 to 30 percent margin | 70 to 80 percent of 700 kg |
Off-centre loading deserves its own table because it is the mechanism behind most complaints about small pneumatic benches. On four springs, a load placed away from the centre does not simply lower the table; it transfers load from the far pair to the near pair. The figures below hold the total at 700 kg, place the offset along one axis, and use the 550 mm spacing assumed above.
| Load Offset from Centre | Near Isolator Pair | Far Isolator Pair | Peak per Isolator | Assessment |
|---|---|---|---|---|
| 0 mm (centred) | 350 kg | 350 kg | 175 kg | Even loading, design condition |
| 100 mm | 477 kg | 223 kg | 239 kg | Acceptable, leveling valve corrects |
| 200 mm | 605 kg | 96 kg | 302 kg | Usable but the far pair is lightly loaded |
| 300 mm | 732 kg | lift-off | 366 kg | Far pair unloads; avoid this layout |
The last row is the one to remember. With a 550 mm support base and a 700 kg payload, an offset of 300 mm drives the far pair to zero and the table starts to lift on that side. Real benches rarely carry 700 kg on a 750 mm frame, so the usable offset is larger in practice, but the trend is what matters: the smaller the tabletop, the shorter the lever arm, and the less eccentricity it tolerates for a given payload. Mounting a heavy laser head at one corner of a 750 mm bench is a layout decision with mechanical consequences.
Applications
A 750 x 750 mm frame is specified when the experiment is a single self-contained setup that benefits from isolation but does not need a shared surface. The list below reflects the measurement types Thorlabs names for this frame family, together with the practical reason each one lands on the smallest size.
- Single-laser standalone bench. One laser head, a beam path of a metre or two, a sample position and a detector. The whole experiment fits inside 0.5 m² of usable surface, and putting it on its own isolated frame removes it from the traffic and the shared equipment on a larger bench.
- Microscopy and imaging. A microscope body, a camera and an illumination train are heavy, compact and tall. The tall part is the point: a microscope is exactly the high-centre-of-gravity load that this page warns about, which is why the body should be mounted as low as the optics allow and why a 750 mm frame carrying a microscope benefits from a granite base plate.
- Cell injection and micromanipulation. These are the most vibration-sensitive procedures in a biology laboratory, because the tool tip and the cell are separated by micrometres and the operator is working under a microscope at the same time. A dedicated 750 mm frame keeps the work off a bench that other people are leaning on.
- Non-contact surface measurement. Optical profilometry, white-light interferometry and confocal sensing all convert floor vibration into height noise. A bench that is 750 mm square is enough for the sensor head, the translation stage and the sample, and the isolation removes the dominant error term.
- Teaching and demonstration laboratories. A 750 mm frame is small enough to fit a teaching bay, robust enough to survive student handling, and instructive enough to show a leveling valve doing its job. The all-steel frame tolerates being moved between rooms far better than a granite slab on rubber pads.
- A supplementary isolated bench inside a larger laboratory. Where a large bench already exists but one sensitive step keeps being disturbed by work going on elsewhere, a second small frame is cheaper than reorganising the room and isolates the step without moving the rest of the experiment.
- Interferometry on a compact scale. A Michelson or Mach-Zehnder built for a single sample, with a path difference of a few hundred millimetres, fits comfortably. Longer paths belong on the 1200 mm or 1500 mm models, where the fold count drops.
Selection Guide
The decision sequence below is written for the case where a 750 mm frame is being considered and the buyer wants to know whether the small size will hold the project or quietly limit it. Work through the steps in order; the first two are arithmetic, the third is the one that decides the outcome.
- Check the optical path length, not the equipment count. Add up the straight-line distance the beam must travel, then divide by the usable span. On a 750 mm tabletop the clear span is roughly 650 mm after allowing 50 mm at each end for mounts, so a 3 m path needs five passes and four folds, and a 4 m path needs seven passes and six folds. Each fold costs about 3 percent of throughput and adds an alignment degree of freedom. If the layout needs more than four folds, the bench is the wrong size and no amount of isolation will fix the beam train.
- Estimate the total mass, then apply a margin. Weigh or estimate the breadboard, every mount, every stage, every cable and the enclosure. Add 20 to 30 percent for the equipment that will arrive in year two. Against a 700 kg rating that gives a working budget of 490 kg to 560 kg. If the estimate lands above that, the frame is undersized even though the raw number looks generous.
- Estimate the height of the centre of gravity and compare it with the support geometry. The support half-spacing on this frame is about 275 mm. Take the mass of each item, multiply by its height above the floor, sum, and divide by the total mass. A result near 0.85 m is a normal bench with the optics at working height. A result near 1.2 m means a tall superstructure: a riser, a hanging enclosure, a vertical translation column, a microscope with a camera stack. Above roughly 1.2 m the rocking behaviour becomes the dominant complaint and the layout should be changed before the frame is ordered.
- Lower the centre of gravity before changing the frame size. The cheapest fix is almost always layout, not hardware. Put the heaviest items directly on the breadboard rather than on a riser above it. Mount the laser head at table level and steer the beam upward with a periscope instead of elevating the source. Replace a tall aluminium riser with a short steel block. Move ballast, granite plates and power supplies to the underside or to the lower shelf where the design provides one. Every kilogram moved from one metre to half a metre cuts the moment in half.
- Choose the frame height. The 700 mm (27.5 in) version suits a seated operator at a standard chair, with the breadboard top at roughly 700 mm plus the breadboard thickness. The 800 mm (31.5 in) version of the same frame suits standing work and taller instrumentation. Height does not affect isolation performance, but it does affect the centre of gravity height measured from the floor, so a taller frame with the same payload has a slightly less favourable geometry.
- Decide on the PWA061 caster set. Order casters if the bench will move between rooms or between experiments. Do not expect to measure while standing on them: the frame should be lowered onto its pads or feet, and the leveling valve allowed to settle, before data is taken.
- Confirm the air supply at the installation position. The frame needs continuous pressurised air, and the supply must be clean and dry. Check where the compressor will stand, how long the line has to be, whether the line will be run across a walkway, and whether the supply stays on overnight. A bench that loses air every evening spends every morning settling.
- Confirm access and floor. A 750 mm frame passes through a standard 800 mm door with clearance, which is one of the practical advantages of the small size. Check the floor for point loading and, on a raised floor, check the panel rating against the 175 kg carried at each corner.
Series Comparison
The PFA range shares one isolator design, one frame height and one load rating across every breadboard size. What changes is the outline, and with it the clear span, the fold count a beam path needs, and the stability margin for a given payload. The table places this model against the rest of the family.
| Model | Breadboard Size | Area (m²) | Clear Long Span | Typical Role |
|---|---|---|---|---|
| PFA51509 | 750 x 750 mm (30 x 30 in) | 0.5625 | 650 mm | Single setup, smallest footprint, most sensitive to centre of gravity |
| PFA51505 | 750 x 900 mm (30 x 36 in) | 0.6750 | 800 mm | One laser plus a short beam train |
| PFA51508 | 750 x 1200 mm (30 x 48 in) | 0.9000 | 1100 mm | Long straight path, fewest folds per metre |
| PFA51507 | 900 x 1200 mm (36 x 48 in) | 1.0800 | 1100 mm | Two stations or a shared centre lane |
| PFA51502 | 900 x 1500 mm (36 x 60 in) | 1.3500 | 1400 mm | Multi-station, general purpose large bench |
| PFA51504 | 1200 x 1500 mm (48 x 60 in) | 1.8000 | 1400 mm | Largest outline, whole-room isolation base |
Read the table along the diagonal rather than down the columns. Moving from PFA51509 to PFA51505 adds 0.1125 m² and 150 mm of span, which converts a five-pass path into a four-pass path for a 3 m beam. Moving from PFA51505 to PFA51508 adds another 0.225 m² and another 300 mm of span, which removes another two folds from a 4 m path. The steps are not linear in cost, but they are close to linear in what they buy: every additional 150 mm of clear span removes roughly one fold from a typical layout.
Two constants are worth stating because they are often assumed to change and do not. Load capacity stays at 700 kg (1,545 lbs) on every size, so a larger tabletop does not carry more; it spreads the same rating over a larger base, which improves the eccentricity tolerance rather than the maximum mass. And the resonant frequencies stay below 1.6 Hz vertical and below 1.2 Hz horizontal on every size, because the isolators are the same. A bigger table is not better isolated. It is more stable, holds a longer beam path with fewer folds, and gives two people room to work.
FAQ
Is 700 kg more capacity than a 750 mm bench can use?
In most installations, yes. The rating is a property of the isolators, which are shared across the whole range, so the smallest frame inherits the capacity of the largest. A typical 750 mm payload of 100 kg to 250 kg uses between a seventh and a third of the rating. That headroom is useful rather than wasteful: it absorbs a granite base plate, motorised stages and a future upgrade without a frame change, and it means the isolators operate well inside their design range.
Will a light payload be isolated less well than a heavy one?
No. The stiffness of an air spring is set by the height and volume of the air column, not by the mass resting on it, so the resonant frequency stays at the design point of below 1.6 Hz vertical and below 1.2 Hz horizontal whether the bench carries 120 kg or 600 kg. What the payload changes is the air column height, which the leveling valve manages automatically within ±0.25 mm. A light bench is not a compromised bench.
What actually goes wrong with a high centre of gravity on a small tabletop?
The bench starts to rock. A tall mass on a compliant spring forms a pendulum with a low natural frequency, and lateral disturbances excite it. The leveling valve responds to the resulting tilt by adjusting pressure, which can feed the motion instead of damping it, and the visible symptom is a slow oscillation that takes a long time to die away. It is not a toppling hazard at normal loads: static tipping on this frame needs roughly 1,888 N of lateral force with the centre of gravity a metre up, which no one applies by leaning. The remedy is layout, not a bigger frame.
How is the centre of gravity estimated in practice?
List every item with its mass and its height above the floor, multiply, add the products, and divide by the total mass. A breadboard on a 700 mm frame with optics at working height typically comes out near 0.85 m. A riser, a hanging enclosure, a vertical column or a camera stack on a microscope pushes it toward 1.2 m and beyond. The comparison that matters is against the 275 mm support half-spacing: the further the centre of gravity rises above that dimension, the more the bench behaves like an inverted pendulum.
What happens when the air supply is switched off?
The tabletop settles onto its supports and the frame behaves as a rigid steel structure. Nothing is damaged, and the optical alignment is not disturbed as long as the descent is gentle. When pressure returns, the leveling valve lifts the tabletop and restores it to level within ±0.25 mm of the previous position, so the experiment can continue without realignment. This behaviour is the reason overnight air loss is a maintenance annoyance rather than an experiment-ending event.
How does this frame differ from a passive air isolation frame?
A passive frame has a fixed air chamber and no leveling valve. It isolates, but its resonant frequency is higher because the chamber geometry is not optimised for the load, and it does not return to level after the load changes: you re-level it by hand. The active pneumatic system on this frame comes in below 1.6 Hz vertical and below 1.2 Hz horizontal, damps through a dual chamber arrangement with orifice damping, and re-levels itself to ±0.25 mm. The cost is the air supply and the valve hardware; the benefit is a lower corner frequency, better low-frequency attenuation and repeatable height.
Is the leveling automatic, and does it need adjusting when equipment is added?
It is automatic. The three-way valve senses tabletop height and adjusts chamber pressure until the tabletop returns to its set point, which also compensates for a changed load distribution. Adding a component to one side of the bench causes a temporary tilt that the valve removes without intervention. The ±0.25 mm figure is the repeatability of that return, so the bench does not drift across a working day as items are added and removed.
Can the frame be moved between rooms?
Yes, with the PWA061 caster set. The frame is all steel and heavy, so the casters are for repositioning on a level floor rather than for transport between buildings. Lower the frame onto its pads or feet and let the leveling settle before taking data. For a 750 mm frame, a standard 800 mm door is wide enough to pass, which is not true of the larger models in the range.
Will the frame work on a wooden floor or a raised access floor?
It will isolate, but the floor has to carry the point load. At rating each corner carries 175 kg (386 lbs), and even a 200 kg payload puts about 50 kg on each corner plus the frame share. On a raised access floor, check the panel rating and the pedestal layout, and consider spreading plates under the feet. A flexible floor also lowers the effective corner frequency of the whole system, because the floor itself becomes part of the spring, so a bench on a sprung floor will not deliver the same performance as the same bench on a slab.
Can the frame be used without a breadboard?
The frame is a support structure and is supplied without a breadboard. It can carry a granite plate, a custom fixture plate or a breadboard of the matching outline, provided the mass stays inside the 700 kg rating and the load is distributed across the four mounting points. A plate that overhangs the frame outline shifts the centre of gravity outward as well as upward, which is the combination to avoid on this size.
Usage Precautions
The precautions below are the ones that decide whether the frame delivers its specification in a working laboratory. None of them is difficult, and all of them are easier to satisfy at the planning stage than after the bench has been installed.
- Provide continuous, clean, dry air. The frame needs a pressurised supply for the whole time isolation is wanted. Moisture in the line damages the diaphragm and the valve, and particulate contaminates the orifice that provides the damping. Use a filter-regulator at the frame inlet and drain the trap regularly. Confirm the required pressure and flow from the installation manual for the exact model rather than inferring them from the load rating.
- Do not treat the air line as a permanent installation without a shutoff. A bench that loses pressure overnight settles onto its supports and lifts again in the morning. That cycle is harmless but it is noise in the data if it happens during a run, so fit an isolation valve and a gauge where the operator can see them.
- Keep the load low and central. On a 750 mm tabletop this is the single most important habit. Place the heaviest items over the centre of the four support points, put ballast and power supplies on the lower shelf or the underside where the design permits, and avoid building a tall riser to raise the optical axis. If the axis has to be high, raise the optics with posts and leave the mass at table level.
- Respect the offset limits. With the 550 mm support spacing assumed in this page, a 700 kg payload offset by 300 mm unloads the far pair entirely. Real payloads are lighter, so the practical limit is wider, but the direction of the effect does not change: the smaller the tabletop, the shorter the lever arm and the less eccentricity it tolerates.
- Level the frame on its pads and feet before pressurising. Set the frame roughly level mechanically, then bring up air pressure and let the valve finish the job. Starting from a badly out-of-level frame forces the valve to work against a mechanical bias and reduces the usable travel of ±9.5 mm on the pads and ±5 mm on the feet.
- Do not measure while standing on the casters. The PWA061 set is for moving the frame. Casters add compliance and a second set of contacts with the floor, and the leveling system has no defined set point while the frame is rolling. Lower onto pads or feet, allow the valve to settle, then measure.
- Keep solvents and sharp objects away from the diaphragms. The rolling rubber diaphragm is the seal that allows frictionless vertical travel. A puncture or a solvent attack destroys the seal, and the isolator then leaks continuously and cannot hold pressure. Wipe spills rather than flooding the frame with cleaning fluid.
- Do not use the frame as a step or a shelf. The breadboard edge is a convenient place to sit a laptop, and the temptation to climb on it to reach a shelf is real. Both add load in the worst possible place, at the edge and high up, and both change the leveling set point without warning.
- Check the floor before installation. Each corner carries 175 kg at rating. On a suspended or raised floor, verify the panel and pedestal capacity, and use spreader plates if the point load is marginal. A floor that deflects under the frame adds a second spring in series and degrades the isolation the frame was bought for.
- Allow settling time after any change. After adding or removing mass, after moving the frame, and after reconnecting air, give the leveling system time to settle before recording data. The valve is fast, but the tabletop has to stop moving before an interferometer will agree with itself.
Disclaimer
The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and specifications may be revised by the manufacturer without notice.
The derived figures in this page are calculations, not manufacturer data. Tabletop areas, keep-out areas, isolator spacing, base area, tipping forces and load-sharing values depend on the assumptions stated next to them, in particular the 100 mm isolator inset and the 120 mm corner keep-out. Replace those assumptions with measured values from the current drawing before using the results for structural or safety decisions.
Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the payload actually installed, the floor the frame stands on, and the quality of the air supply. No transmission curve is reproduced here; where a project requires a specific isolation performance at a specific frequency, request the current performance data for the exact configuration rather than extrapolating from a catalogue summary.
No price is stated on this page. Availability, lead time and price are confirmed at the time of enquiry and may change with stock and currency. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.
Contact Us
For a quotation on PFA51509, or for help deciding whether the 750 mm outline is large enough for a particular layout, send the breadboard dimensions, an estimate of the total mass including mounts and cables, the height of the optical axis above the floor, and confirmation that a continuous air supply is available at the installation position. Those four items are enough to confirm the model and to flag a centre-of-gravity problem before the frame is ordered.
For projects that combine a frame with a breadboard, a granite plate or the PWA061 caster set, send the whole requirement in one message so that the mounting interface, the assembled working height and the access route can be checked together. For a frame going into an existing room, include the door width on the route, the floor construction, and whether the bench will need to move between experiments.









Reviews
There are no reviews yet.