Product Overview

PFA52502 is an active isolation breadboard support frame for a 900 x 1500 mm (36 in x 60 in) breadboard, built on an 800 mm (31.5 in) high frame. It carries 700 kg (1,545 lbs) on four independent, air mounted, active vibration isolators. The vertical resonant frequency is below 1.6 Hz and the horizontal resonant frequency is below 1.2 Hz; vertical transmissibility at resonance is below 13 dB and horizontal transmissibility at resonance is below 8 dB. At 5 Hz both axes are at -18 dB, which is 87.5% of the ground motion removed, and at 10 Hz both axes are at -34 dB, which is 98% removed. Leveling is pneumatic and self-acting to ±0.25 mm (0.010 in), the construction is all steel in Black Paint, the air requirement is 690 kPa (100 psi) maximum, and the PWA061 caster set is optional.

On paper this is simply a larger version of every other frame in the family, with the same isolators and the same specification. In practice it has one problem that the smaller outlines do not have, and the problem is not about vibration at all. A bench 1500 mm long and rated to 700 kg is bought to extend an experiment that already exists. The experiment already exists on a bench that was bought earlier. If that earlier bench is on a 700 mm frame – which is what the range offered before the 800 mm version appeared – then the new bench puts its optical axis exactly 100 mm higher than the old one, and the two halves of the experiment no longer line up.

That is worth stating at the top of the page because it is the question that actually arrives with the enquiry. Nobody asks whether the isolation is adequate; the specification answers that before the question is formed. What they ask is whether they can put the new bench next to the old one and pass a beam between them. The answer is that they can, in one of three ways, and the three ways have very different consequences for the optical design.

The first way is to raise the existing bench by 100 mm. This is the option that looks cheapest and is the one to be most careful about. The frame provides ±6 mm of isolator travel and ±10 mm of leveling foot travel, with 26 mm (1.02 in) of total system height range, so 100 mm is nearly four times the whole adjustment budget. It has to come from a plinth under the feet, and a plinth under an isolation frame is a compliance in series with the isolators. A rigid, grouted steel plinth is acceptable; a stack of timber blocks or adjustable machine feet is not, because it introduces a resonance of its own somewhere in the audio band and destroys the high frequency performance that the frame was bought for.

The second way is to accept the offset and put a two-mirror vertical translation into the beam path. A periscope made from two parallel 45 degree mirrors raises the beam by the separation between them, so 100 mm of separation gives 100 mm of lift. Two reflections preserve the handedness of the beam and preserve its direction, so the image is neither inverted nor rotated. What it costs is two extra reflections – about 5.9 percent of the light at 97 percent per mirror – and, on an ultrafast system, two extra bounces of dispersive delay that have to be compensated. It also puts the beam through two 45 degree surfaces, which is where angular error accumulates.

The third way is to buy the 700 mm version of the same outline, PFA51502, and not have the problem at all. That is not a retreat. The isolation specification is identical between the two heights, the load rating is identical, the breadboard interface is identical, and the published list price difference is about 4.2 percent. If the new bench is going to sit beside an existing 700 mm bench and share a beam with it, the 700 mm version is usually the better engineering decision even though this page is about the 800 mm one.

The rest of the page works through the arithmetic of the offset, the three fixes in more detail, and the procurement principle that avoids the problem in the first place. The outline itself is 1.35 m2 with a 4800 mm perimeter, a 1749.3 mm diagonal and a 1 to 1.667 aspect ratio, giving about 1300 mm of clear span along the 1500 mm axis after 100 mm at each end for mounts and beam clearance. That span is the reason to choose this outline: it takes a long folded layout without an intermediate fold.

Key Features

  • 800 mm (31.5 in) frame height, putting the working surface at 825 to 910 mm with a 25 to 110 mm breadboard and the optical axis at roughly 925 to 1060 mm above the floor.
  • The 100 mm that separates this frame from the 700 mm version of the same outline is the whole subject of this page: it is enough to break an existing beam path and not enough to justify rebuilding one.
  • 900 x 1500 mm (36 in x 60 in) outline: 1.35 m2 of surface, 4800 mm of perimeter, a 1749.3 mm diagonal and about 1300 mm of clear span along the long axis.
  • Isolation is identical to the 700 mm version – same isolators, same corners, same transmissibility – so height is not an isolation variable anywhere in this family.
  • Vertical corner below 1.6 Hz and horizontal corner below 1.2 Hz, which is what allows a 100 mm step in frame height to be treated as a layout problem rather than an optical one.
  • Below 13 dB vertically and below 8 dB horizontally at resonance, where a standard passive frame reaches 24 dB and amplifies by a factor of about 16 at its corner.
  • -18 dB at 5 Hz on both axes, or 87.5% of the ground motion removed, which is the band that carries foot traffic, building pressure waves and air compressors.
  • -34 dB at 10 Hz on both axes, or 98% removed, and 18 dB better than a passive frame at the same frequency.
  • 700 kg (1,545 lbs) total capacity, 175 kg per isolator when evenly shared, which is enough for a second breadboard’s worth of equipment on the same frame.
  • Dual chamber damped pneumatic spring vertically and a trifilar pendulum horizontally, so the two axes have independent corners rather than one compromised compromise between them.
  • Pneumatic self-leveling to ±0.25 mm (0.010 in) through precision three-way valves, which matters when a bench is loaded in two stages as equipment arrives.
  • ±6 mm of isolator travel and ±10 mm of leg travel, with 26 mm (1.02 in) of total system range – three figures that are routinely confused, and none of which covers a 100 mm step.
  • 690 kPa (100 psi) maximum air pressure; without air the breadboard rests on the frame and the isolation is disabled rather than the bench becoming unstable.
  • All steel in Black Paint, so the frame and the breadboard expand together and the frame does not introduce a differential into a long beam path.
  • PWA061 casters, 200 kg (440 lbs) each and 800 kg (1,760 lbs) for the set of four, for moving the frame without dismantling the equipment on it.
  • Four independent isolators, which is what lets the frame sit on an uneven floor without shimming and still return to level.

Technical Specifications

The table below reproduces the manufacturer data for this model. The isolation rows are shared with every other outline and both frame heights in the PFA range, because the isolators are the same parts; the rows specific to this model are the breadboard size, the frame height and the geometry derived from the outline.

Specification Value
Model PFA52502
Product class Active isolation breadboard support frame
Breadboard size accepted 900 x 1500 mm (36 in x 60 in)
Frame height 800 mm (31.5 in)
Vertical resonant frequency below 1.6 Hz
Horizontal resonant frequency below 1.2 Hz
Vertical transmissibility at resonance below 13 dB
Horizontal transmissibility at resonance below 8 dB
Vertical transmissibility at 5 Hz -18 dB (87.5% isolation)
Horizontal transmissibility at 5 Hz -18 dB (87.5% isolation)
Vertical transmissibility at 10 Hz -34 dB (98% isolation)
Horizontal transmissibility at 10 Hz -34 dB (98% isolation)
Load capacity 700 kg (1,545 lbs)
Load per isolator at rated capacity 175 kg (386 lbs) when evenly shared
Isolators height adjustment range ±6 mm (0.25 in)
Self leveling repeatability ±0.25 mm (0.010 in)
Legs height adjustment range ±10 mm (0.4 in)
Air pressure required 690 kPa (100 psi) maximum
Finish Black Paint
Construction All steel
Isolator count and type Four independent, air mounted, active vibration isolators
Leveling method Pneumatic self-leveling, precision three-way valves
Optional casters PWA061 (set of 4)
Largest breadboard supported by family 1200 x 1800 mm (48 in x 72 in)
Outline area 1.3500 m2
Outline perimeter 4800 mm
Outline diagonal 1749.3 mm
Aspect ratio 1 to 1.667, long axis 1500 mm
Clear span along the 1500 mm axis about 1300 mm after 100 mm at each end for mounts

Table 1. Manufacturer specification for PFA52502, with outline geometry and per-isolator load derived from the stated breadboard size and capacity.

Three things in that table are read wrongly often enough to be worth separating. The ±6 mm is the travel of the isolator bodies and the ±10 mm is the travel of the leveling feet under the legs, and they are different parts with different ranges. The manufacturer product description also quotes leveling pads at ±9.5 mm (±0.375 in) and leveling feet at ±5 mm (±0.2 in), which is a second description of the same region of the frame written in different terms; for selection the table above governs. The 26 mm (1.02 in) in the manufacturer text is the assembled system’s total height range. None of the three is a substitute for the 100 mm between the two frame heights, which is why a mixed-height laboratory cannot be levelled into agreement.

The percentages in brackets beside the decibel figures are the isolation, not the transmission. -34 dB is a transmission factor of 0.0200, so 2.0 percent of the ground motion arrives and 98 percent does not; -18 dB is 0.1259, so 12.6 percent arrives and 87.4 percent is removed, quoted as 87.5 percent. Attenuation carries the negative sign, so a larger negative number and a larger percentage mean the same thing. When two benches are compared, compare the decibels: they add, and percentages do not.

Vertically the frame is a dual chamber, damped pneumatic spring. The breadboard rides on the pressure in an air chamber and sits on a piston, and a rolling rubber diaphragm seals that piston to the upper chamber so vertical travel is almost frictionless while lateral movement is blocked. Floor motion drives air through a high damping orifice from the lower chamber to the upper one, which is what turns a soft spring into a usable one: the oscillation is damped and the settling time collapses. The two chamber volumes are the design variable that trades corner frequency against damping.

Horizontally the frame is a trifilar suspension: three wires, with the pneumatic isolators standing on top of them, so the restoring force after a lateral displacement comes from gravity rather than from an elastic element. That is why the horizontal corner can sit at 1.2 Hz without the frame feeling springy. Oscillation at that corner is suppressed by oil free dampers running between the bottom of each vertical isolator and the outer cylinder. Expressed as equivalent static deflections, below 1.6 Hz is a spring that compresses about 97 mm under its own load and below 1.2 Hz is a pendulum about 173 mm long; at 700 kg the implied stiffness is about 70.7 kN/m vertically and 39.8 kN/m horizontally. Those are derived figures, not manufacturer data, but they explain why the frame is soft by design.

Leveling uses precision three-way valves that are actuated by movement of the working surface itself. A tilt opens the appropriate valve, air is admitted or exhausted, and the surface returns to within ±0.25 mm of its previous level. On a bench that will later be matched to another bench, that repeatability is the useful part of the specification: it means the axis height is stable to a quarter of a millimetre, so a 100 mm mismatch between two frames is a real mismatch and not a leveling artefact.

Applications

The applications below are the ones where a 1500 mm long isolated surface is the requirement rather than a luxury, and where the height question has to be answered alongside the length question. Each of them involves extending or joining an experiment rather than starting one.

  • Extending an existing experiment onto a second bench. The classic case: a two-metre layout that has outgrown a 900 x 1200 mm bench. The new bench takes the delivery arm, and the beam crosses the gap between the two. This is where the 100 mm offset becomes a design item rather than a footnote.
  • Long-path interferometry with a separated reference arm. A reference arm that runs 1300 mm before folding is a reference arm that does not need an intermediate mirror, and an interferometer with one fold instead of two is an interferometer with 3 percent more light and one less thing to align.
  • Chirped pulse amplification and grating compressors. A grating pair or a Treacy compressor needs length by construction. 1300 mm of clear span takes a compressor that would otherwise need a fold, and the -34 dB at 10 Hz keeps the grating separation stable against the building services noise that dominates in that band.
  • Multi-pass cells and Herriott configurations. These need a long base line and a very stable one, because the spot pattern on the mirrors is a lever arm for any angular motion. The below 1.2 Hz horizontal corner is the relevant specification, not the vertical one.
  • Optical tweezers and holographic trapping. A trapping bench typically has a source arm, a beam shaping arm and an imaging arm, all of which want to be long and straight. The 1300 mm span holds them without crossing, and the two-operator capacity of the 900 mm depth lets one person run the trap while another images.
  • Large-aperture beam relay and expansion. Expanding a beam to 100 mm or more needs propagation distance between the lenses, and the whole relay wants to sit on one continuous isolated surface rather than across a joint between two benches. That is the argument for length over area on this outline.
  • A production or verification station feeding a larger system. A bench at the head of a beamline, aligned independently and then delivered. If the receiving table is also on an 800 mm frame, the axis matches without a periscope, which is the strongest argument for standardising on the taller height across a new installation.

Selection Guide

There are two decisions to make before ordering this frame, and they are best taken in a particular order. The first is whether the laboratory can standardise on one frame height, because that decision removes the second problem entirely. The second, only if the answer to the first is no, is how to reconcile a 100 mm offset in the beam path.

Before either, it is worth confirming that an active frame is needed, because the height question is moot on a passive frame. The table below is the manufacturer summary of common vibration sources, and the frequency column is the one that decides the question.

Source Frequency (Hz) Amplitude (inches)
Air compressors 4 – 20 10^-2
Handling equipment 5 – 40 10^-3
Pumps (vacuum, compressed, or non-compressed fluids) 5 – 25 10^-3
Building services 7 – 40 10^-4
Foot traffic 0.5 – 6 10^-5
Acoustics 100 – 10,000 10^-2 to 10^-4
Punch presses up to 20 10^-2 to 10^-5
Transformers 50 – 400 10^-4 to 10^-5
Elevators up to 40 10^-3 to 10^-5
Building motion 46 / height in metres 10^-1
Building pressure waves 1 – 5 10^-5
Railroad 5 – 20 ±0.15 g
Highway traffic 5 – 100 ±0.001 g

Table 2. Common vibration sources and their frequency content, as published by the manufacturer. Ambient noise in a laboratory is typically concentrated between 10 and 100 Hz.

Four rows in that table reach below 2 Hz: foot traffic from 0.5 Hz, building pressure waves from 1 Hz, air compressors from 4 Hz and building motion, which for a 30 m building is about 1.5 Hz. A passive frame with a 3.5 Hz corner cannot isolate any of them, and at its own resonance it amplifies by 24 dB. That is the technical case for the below 1.6 Hz and below 1.2 Hz corners, and it applies equally to both frame heights, which is why the height decision can be made purely on geometry.

Now the offset arithmetic. If the beam has to fall or rise 100 mm between two benches, there are two ways to do it with mirrors, and the consequences are different. A periscope of two parallel 45 degree mirrors translates the beam by the mirror separation without changing its direction or inverting the image. A symmetric dog-leg of two mirrors, each deviating the beam by the same angle, does the same thing over a longer horizontal run. The table below shows the deviation angle required for a 100 mm change over various horizontal runs, and what that means for the height of each successive optic if the beam is left at that angle instead of being returned to horizontal.

Horizontal run over which the 100 mm is taken Beam angle to horizontal Height change per 200 mm of further run Practical reading
300 mm 18.43 deg 66.7 mm Steep dog-leg, compact, two well separated mirrors
500 mm 11.31 deg 40.0 mm Workable dog-leg, needs clear floor between mirrors
800 mm 7.13 deg 25.0 mm Long dog-leg, competes for bench space
1000 mm 5.71 deg 20.0 mm Starting to look like a tilted beam path
1500 mm 3.81 deg 13.3 mm Every mount along the run needs a different post height
2000 mm 2.86 deg 10.0 mm Not a fold any more, it is a sloping layout
3000 mm 1.91 deg 6.7 mm A sloping layout that will never look level

Table 3. Geometry of a 100 mm height change, calculated as the arctangent of 100 mm divided by the horizontal run. These are arithmetic, not manufacturer data.

The last two columns explain why the third option, buying the 700 mm version, is often the right one. A 100 mm change taken over a short run needs a compact two-mirror assembly and costs two reflections; a 100 mm change taken over a long run turns the beam into a slope, and a sloping beam means every mount along that run sits at a different height. At a typical 200 mm optic spacing and a 2.86 degree slope, each successive mount is 10 mm lower than the last. Post heights come in fixed increments and post holders have a limited range, so a sloping run is a run of shims, and a run of shims is a run that drifts.

The alternative to a fold is to tilt a mirror and let the beam walk. That does not work at these distances, and the numbers show why. A mirror rotated by an angle deflects the beam by twice that angle, so the lateral walk over a propagation distance D is 2 times the rotation times D. The table below gives the walk for a range of mirror setting errors, and then the mirror accuracy needed to hold a half millimetre.

Propagation distance 10 arcsec error 30 arcsec error 1 arcmin error 2 arcmin error Mirror accuracy for 0.5 mm walk
1000 mm 0.097 mm 0.291 mm 0.582 mm 1.164 mm 51.6 arcsec
2000 mm 0.194 mm 0.582 mm 1.164 mm 2.327 mm 25.8 arcsec
3000 mm 0.291 mm 0.873 mm 1.745 mm 3.491 mm 17.2 arcsec

Table 4. Beam walk caused by mirror setting error, calculated as twice the rotation angle times the propagation distance, with the mirror accuracy required to hold a 0.5 mm walk over the same distance.

Read the last column as a specification on the mounts, not on the operator. To keep a beam within half a millimetre over two metres, the mirror has to be set to about 26 arcseconds, which is 0.007 degrees. No micrometer-driven kinematic mount is adjusted to that by eye, and no fold that has been added to compensate for a frame height is going to hold it across a thermal cycle. The conclusion is that the offset should be removed mechanically – by a plinth or by choosing the other frame – rather than absorbed optically.

The three options then compare as follows, and the comparison is the recommendation:

Option What it costs What it risks When it is the right answer
Raise the existing 700 mm frame on a plinth A rigid grouted steel plinth plus installation time A compliance in series with the isolators; a second resonance in the audio band if the plinth is not rigid The existing frame is already installed and cannot be replaced
Add a two-mirror periscope or dog-leg Two reflections, about 5.9 percent of the light, two dispersive bounces on ultrafast systems Angular error at two 45 degree surfaces; alignment time; a fold that has to be re-set after any thermal cycle The offset is small, the beam is not ultrafast, and the layout has room for the assembly
Buy the 700 mm version of the same outline About 4.2 percent lower list price than this frame None on the optical side; the working surface is 100 mm lower The laboratory already standardises on 700 mm, or the station will be used seated

Table 5. The three ways of reconciling a 100 mm frame height difference, with the conditions under which each is appropriate.

If the decision is to standardise, the order in which to make that decision matters. Work through it as follows: list every frame height already in the laboratory and the age of each; identify which benches share a beam with which; if all shared beams are already at one height, stay at that height for any new bench that joins them; if a new bench has to be standing height and cannot be matched, decide whether the whole laboratory will migrate to 800 mm over the next few years, and if the answer is yes, start migrating with the new bench and accept the offset once rather than repeatedly; and if the answer is no, buy the 700 mm version now and plan a raised platform or a seated station for the people who need height.

One further consideration applies to this outline specifically. At 1500 mm long, a bench is likely to be the one that a beam leaves from rather than the one it arrives at, which means the offset appears at the downstream end of the layout where the beam is most likely to be collimated and least tolerant of a fold. That is an argument for settling the height before the layout is drawn, not after.

Series Comparison

Within the family, this outline is the second largest and the one that pairs with the 1200 x 1500 mm frame. The table below sets out the six 800 mm outlines with the numbers that decide how much layout each will take, including the clear span, which is the figure that governs how many folds a long beam path needs.

Model Breadboard Size Area (m2) Perimeter (mm) Diagonal (mm) Clear Span Typical Use
PFA52509 750 x 750 mm 0.5625 3000 1060.7 about 550 mm Single instrument
PFA52505 750 x 900 mm 0.6750 3300 1171.5 about 700 mm One operator, short path
PFA52508 750 x 1200 mm 0.9000 3900 1415.1 about 1000 mm One operator, long path
PFA52507 900 x 1200 mm 1.0800 4200 1500.0 about 1000 mm Two operators
PFA52502 900 x 1500 mm 1.3500 4800 1749.3 about 1300 mm Two stations or one long path
PFA52504 1200 x 1500 mm 1.8000 5400 1920.9 about 1300 mm Multi-station

Table 6. The six 800 mm outlines in the PFA range. Area, perimeter and diagonal are calculated from the stated breadboard size; clear span assumes 100 mm reserved at each end.

The pairing table below is the one to use when the question is whether the 100 mm of extra height is worth the offset problem. The isolation specification, the load rating, the leveling repeatability, the air requirement and the breadboard compatibility are identical between the two columns; the differences are the frame height, the resulting axis height and the published price.

Breadboard Size 700 mm Frame 800 mm Frame Axis with 60 mm Board and 125 mm Mount Relative Cost of 800 mm
750 x 750 mm PFA51509 PFA52509 885 mm against 985 mm about 0.4 percent more
750 x 900 mm PFA51505 PFA52505 885 mm against 985 mm about 0.4 percent more
750 x 1200 mm PFA51508 PFA52508 885 mm against 985 mm about 0.4 percent more
900 x 1200 mm PFA51507 PFA52507 885 mm against 985 mm about 0.4 percent more
900 x 1500 mm PFA51502 PFA52502 885 mm against 985 mm about 4.2 percent more
1200 x 1500 mm PFA51504 PFA52504 885 mm against 985 mm about 4.2 percent more

Table 7. The two frame heights for each outline, with the optical axis height each produces and the relative cost difference expressed as a percentage only. No absolute price is stated on this page.

The last column is relevant to the decision on this page because it shows that the two largest outlines are the two where the taller frame carries a real premium, about 4.2 percent, while the four smaller ones carry about 0.4 percent. This outline is in the first group. So the offset problem is being created at a 4.2 percent premium rather than at a negligible one, which tilts the decision towards the 700 mm version unless the standing height is genuinely needed.

Against PFA52504, the 1200 x 1500 mm frame, the difference is depth rather than length: 900 mm against 1200 mm for the same 1500 mm length. The 900 mm depth gives two operators 450 mm each, which is only just enough for a face-to-face station; the 1200 mm depth gives 600 mm each and is the comfortable answer for a genuinely shared bench. If the extra 300 mm of depth is not needed, this frame is the better buy because the far edge stays reachable and the floor requirement is smaller.

Against PFA52508, the 750 x 1200 mm frame, the difference is both dimensions, and the choice turns on the clear span. 1300 mm against 1000 mm is the difference between a layout that fits without an intermediate fold and one that does not. One avoided fold is worth about 3 percent of the light and, on an ultrafast system, one avoided set of dispersive mirrors – which is usually worth more than the 3 percent.

FAQ

Can I put this frame next to an existing 700 mm frame and pass a beam between them?

Yes, but not directly. The optical axes differ by 100 mm, which is 3.8 times the entire height adjustment range of the frame, so the gap cannot be closed with the ±6 mm isolator travel and ±10 mm foot travel. The three ways to close it are a rigid plinth under the existing frame, a two-mirror periscope or dog-leg in the beam, or buying the 700 mm version of this outline instead. Table 5 on this page compares the three.

Why not just tilt a mirror to bring the beam down 100 mm?

Because the beam does not stay down. A mirror rotation of one angle deflects the beam by twice that angle, so a 1 arcminute setting error walks the beam 1.16 mm over two metres and 1.75 mm over three. Holding a half millimetre over two metres requires the mirror to be set to about 26 arcseconds, which is 0.007 degrees, and no fold added to compensate for a frame height will hold that across a thermal cycle. Removing the offset mechanically is more reliable than absorbing it optically.

Does the 800 mm frame isolate less well than the 700 mm frame?

No. The manufacturer publishes one specification table covering both heights and every isolation figure in it is identical: below 1.6 Hz vertical, below 1.2 Hz horizontal, below 13 dB and below 8 dB at resonance, -18 dB at 5 Hz, -34 dB at 10 Hz, 700 kg capacity, ±0.25 mm leveling repeatability, 690 kPa air pressure. The isolators are the same parts on both frames.

What does -34 dB at 10 Hz mean in percent?

It means 2.0 percent of the ground motion is transmitted and 98 percent is removed. The bracketed percentage in the specification is the isolation, not the transmission. At 5 Hz the figure is -18 dB, which is 12.6 percent transmitted and 87.4 percent removed, quoted as 87.5 percent.

How much clear span does 1500 mm of length actually give?

About 1300 mm, after reserving 100 mm at each end for mounts and beam clearance. The 1749.3 mm diagonal is the number that governs how the frame and the breadboard are moved, and the 1300 mm span is the number that governs how much layout fits without a fold.

What load can be placed on the bench?

700 kg (1,545 lbs) total, which includes the breadboard. A 900 x 1500 mm by 60 mm Nexus board is on the order of 90 to 100 kg, so the equipment budget is about 600 kg before margin and roughly 420 to 480 kg after a 20 to 30 percent margin. Per isolator the rated share is 175 kg when the load is evenly distributed.

Can the frame be raised by 100 mm with a plinth?

It can, provided the plinth is rigid. A grouted steel plinth that behaves as a rigid extension of the floor is acceptable. Timber blocks, stacked plates or adjustable machine feet are not, because they put a compliance in series with the air springs and introduce a second resonance somewhere in the audio band, which is exactly where a passive frame already fails.

What does a two-mirror periscope cost optically?

About 5.9 percent of the light at 97 percent reflectivity per mirror, and on an ultrafast system two extra bounces of dispersive delay that have to be compensated. It also preserves the handedness of the beam and its direction, because two parallel mirrors produce a translation rather than a rotation, so the image is neither inverted nor rotated.

What air supply does it need?

690 kPa (100 psi) maximum, dry and oil free, supplied continuously. Moisture and oil carry over will block the leveling valves and the damping orifices, and the symptom is a slow drift out of level rather than an obvious failure. With the air removed the breadboard rests securely on the frame and the isolation system is disabled.

Is the breadboard included?

No. The frame is the support structure; the breadboard is a separate item and the two are ordered together. The frame accepts any breadboard of the stated outline, and the same breadboard fits either frame height because the mounting interface is identical.

How much floor does the frame need?

The frame occupies the breadboard footprint, so about 900 x 1500 mm plus access. Allow 600 mm on each working side and 300 mm at the ends for the isolators and air lines, which gives roughly 2100 x 2100 mm of usable floor for a two-person station.

Usage Precautions

The precautions below are the ones that matter when a bench this long is installed next to existing equipment. Most of them are about the offset, about the air supply and about the fact that a 1500 mm bench is stiff in one direction and not in the other.

  • Settle the frame height before the layout is drawn. Once a beam path has been built around a 100 mm offset, the offset becomes a permanent feature of the design and every subsequent change has to work around it.
  • Do not attempt to close a 100 mm offset with the frame adjustments. The ±6 mm isolator travel and ±10 mm foot travel give 26 mm of total system range, which is 3.8 times short of what is needed.
  • If a plinth is used, make it rigid and grout it. A compliant plinth in series with the air springs produces two resonances instead of one and degrades exactly the high frequency performance the frame was bought for.
  • If a periscope is used, mount both mirrors on the same rigid structure, not one on each bench. Two mirrors on two independently isolated benches will move relative to each other, and the beam will move with them.
  • Supply dry, oil free air at no more than 690 kPa (100 psi). The leveling valves and damping orifices are small passages and they do not tolerate moisture or oil carry over.
  • Level the frame on its feet before pressurising, then pressurise and let the self-leveling settle before bolting anything down. Leveling a pressurised frame fights the valves.
  • Distribute load along the length, not just across the width. A 1500 mm bench with a heavy laser at one end and light optics at the other loads two isolators much harder than the other two, and the self-leveling system can compensate for height but not for load.
  • Do not use the frame as a rigid datum while it is pressurised. A below 1.6 Hz vertical corner means the surface moves under a hand push; remove the air if a procedure needs rigidity.
  • If casters are fitted, do not roll a 1500 mm frame over a threshold or a cable duct. The PWA061 set is rated 200 kg per caster and 800 kg for the four against a 700 kg frame, but a tilt while rolling puts the whole load on two casters and will spill anything not clamped.
  • Check the floor for flatness along the full length. A 1500 mm frame spanning a joint between two floor slabs will rock, and the leveling feet only have 10 mm of travel each way.
  • Keep the rolling diaphragms at the base of each isolator clean. They are the one part of the mechanism that is sensitive to grit, and blowing dust around the base with compressed air is the fastest way to shorten their life.

One point about the length deserves separate mention. A 1500 mm bench has a low frequency rocking mode along its long axis that a 900 mm bench does not, because the mass is distributed further from the centre and the trifilar suspension has to control a larger moment of inertia. The manufacturer’s below 1.2 Hz horizontal figure covers the horizontal translation, and the rocking mode sits above it, but the practical consequence is that the ends of a long bench move more than the centre under a lateral disturbance. If a measurement is made at one end, it is worth checking whether the same measurement at the centre gives the same answer, because that difference is the rocking mode showing itself.

The second point is about the diagonal. At 1749.3 mm this outline will not pass through a standard 900 mm door on its side, so the frame and the breadboard have to be brought in separately and assembled in the room, or brought in through a loading bay. Confirm the access route before ordering, and confirm it for the breadboard as well as for the frame, because the breadboard is the heavier and more awkward of the two.

Disclaimer

The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and the manufacturer may revise specifications without notice.

The beam angle table, the beam walk table, the mirror accuracy column and the axis heights are calculations, not manufacturer data. The beam angle table assumes a straight line between the two points at which the height changes and a 100 mm total change; the beam walk table assumes a flat mirror, a collimated beam and a straight line propagation, and it ignores air turbulence, thermal gradients and mount hysteresis, all of which add to the walk in practice. The transmission loss of about 5.9 percent for a two-mirror periscope assumes 97 percent reflectivity per mirror at normal incidence, which is optimistic for a 45 degree dielectric coating at some wavelengths.

The static deflection and stiffness figures derived from the resonant frequencies are calculated from the published corners and assume a linear spring and a linear pendulum. The per-isolator load figure is derived from the rated capacity. Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the payload installed, its distribution, the floor and the quality of the air supply. No transmission curve for the isolation system is reproduced here; where a project requires a specific isolation performance at a specific frequency, request current performance data for the exact configuration.

No price is stated on this page. The percentage comparisons in the series comparison refer to published list prices for the two frame heights of the same outline and are given as percentages only, because list prices change with stock and currency. Availability, lead time and price are confirmed at the time of enquiry. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.

Contact Us

For a quotation on PFA52502, or for help working out how to join this bench to one already installed, send the frame height of every bench already in the laboratory, which of them share a beam, the height of the beam where it crosses between benches, whether the layout is ultrafast, and confirmation that a dry air supply at up to 690 kPa is available. Those five items decide whether the offset can be avoided, absorbed or has to be folded.

For a project that is starting from nothing and choosing a height for a whole installation, say so and include the room plan. Standardising on one height across an installation costs nothing at the outset and saves a periscope, a plinth or a sloping beam path later, and the choice is easier to make once than to revisit.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PFA52502 Active Isolation Breadboard Support Frame, 800 mm Height, 900 x 1500 mm”

Your email address will not be published. Required fields are marked *

中文EN