QQ: 859818709

f-number and NA Calculator

f-number and NA Calculator

🔭 F/# & Numerical Aperture Calculator

F/# & Numerical Aperture Calculator

Calculate the f-number (aperture value) and numerical aperture N.A. of an optical system, understand the conversion between the two ways of describing light-gathering ability, and support laser system design and component selection.

🔭
F-number
F/# = f / D
Focal length ÷ entrance pupil diameter
Numerical aperture
N.A. = n·sin θ
Refractive index of the medium × sine of the half-angle
Conversion relationship
F/# ≈ 1 / (2 · N.A.)
(in air, small-angle approximation)

🔭 F/# & N.A. Calculator

Enter the focal length and entrance pupil diameter, or solve for F/# from a known N.A., to calculate all parameters automatically



mm

Effective focal length of the lens or optical system


mm

Effective diameter of the stop or entrance pupil

Air = 1.0, water = 1.333, oil immersion = 1.515


📊 Calculation results
🔭 F-number F/#
—
f/D
📐 Numerical aperture N.A.
—
Dimensionless
📏 Half-cone angle θ
—
°

Formula details

The f-number and numerical aperture are two equivalent ways of describing the light-gathering ability of an optical system

① F-number definition
F/# = f / D
f: effective focal length (mm);D: entrance pupil diameter (mm). The smaller the f-number, the stronger the light-gathering ability of the system and the smaller the spot at the focal plane.
② Numerical aperture definition
N.A. = n · sin θ
n: refractive index of the image-side medium;θ: half-cone angle of the ray (the angle subtended from the focus to the edge of the entrance pupil). The larger the N.A., the higher the resolution and the stronger the light-gathering ability.
③ Relationship between the half-angle and focal length/entrance pupil
θ = arctan ( D / 2f )
From geometry, the half-cone angle θ subtended by the entrance pupil at the focus satisfies tan θ = D/(2f). Substituting into equation ② gives the exact N.A.
④ Conversion between F/# and N.A.
F/# = n / (2 · sin θ) = n / (2 · N.A.)
An exact relationship (not an approximation). In air, n=1, so F/# = 1/(2·N.A.), i.e. N.A. = 1/(2·F/#).
⑤ Small-angle approximation
N.A. ≈ D / (2f) = 1 / (2 · F/#)
When F/# is large (>5), sin θ ≈ tan θ ≈ θ, so the two are approximately equal. At small F/# (e.g. F/1.2) the difference is significant and the exact formula must be used.
⑥ Working f-number (finite conjugate distance)
F/#working = (1 + m) · F/#∞
m: lateral magnification (image height / object height). When the object distance is finite, the effective f-number increases and the resolution decreases. In laser processing m is usually very small and can be neglected.

Parameter details

The relationship between f-number, N.A. and half-cone angle

🔭

F-number F/#

  • In photography it is called the aperture value (f/1.4, f/2.8, f/5.6 …)
  • Each f-stop changes the f-number by a factor of √2 ≈ 1.414
  • Common range for industrial lenses: F/1.2 ~ F/22
  • Smaller f-number → greater light throughput → smaller focal spot
📐

Numerical aperture N.A.

  • Commonly marked on microscope objectives (0.1, 0.25, 0.95 …)
  • N.A. = n·sinθ, with the maximum limited by the refractive index of the medium
  • The fastest in air is about N.A. = 0.95 (F/0.53)
  • Oil-immersion objectives can reach N.A. = 1.4 (F/0.36)
  • N.A. directly determines the diffraction-limited resolution
📏

Half-cone angle θ

  • Half of the angle subtended from the focus to the edge of the entrance pupil
  • θ = arctan(D/2f)
  • At F/1.0, θ ≈ 26.6°
  • At F/5.6, θ ≈ 5.1°
  • In laser processing it affects the power density distribution at the focus

📋 Common F/# and N.A. conversion table

Exact conversion in air (n = 1.0)

F/# N.A. (exact) N.A. (approximate) Half-angle θ Typical application
F/1.0 0.4472 0.5000 26.57° Ultrafast microscope objective
F/1.4 0.3307 0.3571 19.29° Large-aperture photographic lens
F/2.0 0.2425 0.2500 14.04° Fibre coupling lens
F/2.8 0.1741 0.1786 10.02° f-theta field lens
F/4.0 0.1231 0.1250 7.07° General imaging lens
F/5.6 0.0884 0.0893 5.08° Standard photographic aperture
F/8.0 0.0622 0.0625 3.56° High-quality imaging
F/11 0.0453 0.0455 2.59° Depth-of-field priority applications
F/16 0.0312 0.0313 1.79° Maximum depth of field

⚠️ Common pitfalls and notes

Common points of confusion in F/# and N.A. conversion

Does F/# = 1/(2·N.A.) always hold?

This is only an approximate formula. The exact relationship is F/# = n/(2·sinθ); at small f-numbers (e.g. F/1.2) the error can exceed 10%.

Are N.A. and F/# the same thing?

No, but they are equivalent. N.A. is mostly used in microscopy and fibre optics, while F/# is mostly used in photography and industrial lenses. The two can be converted into each other.

Are the working f-number and the nominal f-number the same?

When a lens is focused at close distance, the effective f-number = (1+m) × nominal f-number. The effect is significant in macro photography, while in laser processing m is usually extremely small and can be neglected.

Is the entrance pupil diameter the same as the lens outer diameter?

Not necessarily. The entrance pupil is the image of the stop as seen from the object side and may be smaller than the lens outer diameter. In multi-element lenses the front group may magnify or reduce the entrance pupil.

Can the refractive index of the medium be ignored?

The N.A. of an oil-immersion objective can exceed 1.0 because n_oil ≈ 1.515. The refractive index of the medium must be entered in the calculation; you cannot simply assume n=1.

Is a smaller f-number always better?

A smaller f-number lets in more light, but aberration is more severe and the depth of field is shallower. Optical design requires a trade-off between light throughput, image quality and depth of field.

💡 Common applications

🔬
Laser focusing system design
When selecting a focusing lens, the f-number determines the focal spot size and power density. An F/2.8 field lens produces a smaller processing spot than an F/5.6 field lens.
🔗
Fibre coupling matching
The accepting N.A. of the fibre determines the required f-number of the coupling lens. The lens f-number must be ≤ the f-number corresponding to the fibre N.A.; otherwise part of the light cannot enter the fibre.
📷
Imaging system selection
The f-number of a camera lens affects the light intake and the diffraction-limited resolution. High-resolution imaging requires a balance between f-number, sensor pixels and optical aberrations.

📋 Frequently asked questions

Q: Why is the spot smaller at a smaller f-number?
The diffraction-limited spot diameter is d ≈ 2.44·λ·F/#. The smaller the f-number, the smaller the diffraction spot at the focus and the higher the power density. This is why laser processing uses F/2.8 or even smaller field lenses.
Q: Why do microscopes use N.A. while cameras use f-number?
Historical convention. Microscope objectives have a fixed focal length and focus on the image-side light-gathering ability (N.A. is more intuitive); camera lenses need zooming, so the f-number is more convenient for unified specification.
Q: Can N.A. exceed 1.0?
Yes, but only in an immersion medium. N.A. = n·sinθ; in air n=1 and the maximum sinθ=1, so N.A.≤1. But an oil-immersion objective has n≈1.515, so N.A. can reach 1.4.
Q: Do F/1.0 optical systems exist?
They exist but are extremely difficult to design. F/1.0 requires the entrance pupil diameter to equal the focal length, corresponding to a half-cone angle of 26.6°, and aberration correction is very difficult. Leica once produced the Noctilux 50mm F/1.0 lens.

中文EN