🕶️ Optical Density OD ↔ Transmittance Calculator
Optical Density OD ↔ Transmittance Calculator
Essential for selecting filters, attenuators and laser safety glasses: enter the optical density OD to automatically convert to transmittance T%, blocking rate and attenuation in decibels; supports stacking multiple elements (OD values add) and incident/transmitted power conversion. Remember: every increase of 1 in OD reduces the transmittance to 1/10.
🕶️ Optical Density OD ↔ Transmittance Calculator
Mode A: calculate transmittance from OD (supports stacking); Mode B: calculate OD from transmittance; optionally enter incident power to calculate transmitted power automatically
Nominal OD of the filter/protective eyewear, e.g. OD3
Added when several elements are stacked, e.g. add another OD3
If left blank it is taken as 0; transmittances multiply, ODs add
W
When filled in, the transmitted power P_out is calculated automatically
Formula details
Optical density (OD) is the negative base-10 logarithm of transmittance; understanding this is all you need for the conversions
Parameter details
Three core concepts: OD, transmittance and stacking multiple elements
Optical density OD
- Dimensionless, OD = −lg T, on a logarithmic scale
- The larger the OD, the stronger the attenuation; OD=0 means fully transmitting
- A difference of 1 in OD → a tenfold difference in transmittance; a difference of 3 → a thousandfold
- Filters commonly range from OD0.1 to OD6; protective eyewear can reach OD7+
- OD must correspond to a specific wavelength (wavelength selectivity)
Transmittance T / T%
- Two ways of writing it: T (fraction, 0~1) and T% (0~100%)
- T% = 100 × 10⁻ᴼᴰ, uniquely determined by OD
- At high OD, T% is extremely small: OD7 → 10⁻⁵% (one part in a million)
- Blocking rate = 100% − T%; do not confuse it with transmittance
- For linear materials, T is independent of the incident power level
Stacking rule for multiple elements
- In a serial optical path, transmittances multiply: T=T₁·T₂·T₃
- Equivalent to adding ODs: OD_total=OD₁+OD₂+OD₃
- Example: OD3+OD3=OD6 (not OD3, and certainly not OD9)
- The ODs of the elements can be added directly only if they are specified at the same wavelength
- Stacking also requires consideration of interface reflections, damage threshold and heat dissipation
📋 OD quick-reference table (OD 0~8)
Transmittance, blocking rate, attenuation in dB and transmitted power for 100 W incident power
| OD | Transmittance T% | Blocking rate | Attenuation dB | 100 W incident → P_out |
|---|---|---|---|---|
| 0 | 100% | 0% | 0 dB | 100 W |
| 0.3 | 50.12% | 49.88% | −3 dB | 50.12 W |
| 0.5 | 31.62% | 68.38% | −5 dB | 31.62 W |
| 1 | 10% | 90% | −10 dB | 10 W |
| 2 | 1% | 99% | −20 dB | 1 W |
| 3 | 0.1%(10⁻³) | 99.9% | −30 dB | 0.1 W(100 mW) |
| 4 | 0.01%(10⁻⁴) | 99.99% | −40 dB | 10 mW |
| 5 | 0.001%(10⁻⁵) | 99.999% | −50 dB | 1 mW |
| 6 | 10⁻⁴%(0.0001%) | 99.9999% | −60 dB | 100 μW |
| 7 | 10⁻⁵%(0.00001%) | 99.99999% | −70 dB | 10 μW |
| 8 | 10⁻⁶%(0.000001%) | 99.999999% | −80 dB | 1 μW |
Note: −3 dB corresponds to about 50% transmittance (half-power point); for non-integer OD, T% is likewise calculated as T%=100·10⁻ᴼᴰ. The 100 W column assumes linear attenuation; in actual use the laser-induced damage threshold (LIDT) of the component must not be exceeded.
⚠️ Common pitfalls and notes
Six most common mistakes in OD selection
OD is a linear scale, so OD6 is only twice as strong as OD3?
Wrong. OD is a logarithmic scale: each difference of 1 in OD means a tenfold difference in transmittance. OD6 is 1000 times stronger than OD3 (transmittance 0.0001% versus 0.1%). Treating OD as a linear value is the most common mistake.
Do transmittances add when elements are stacked?
Wrong. In a serial optical path transmittances multiply and ODs add: OD3+OD3=OD6 (T=0.1%×0.1%=0.0001%), by no means 0.1%+0.1%=0.2%, nor OD9.
OD6 = 60% blocking?
A serious error. The transmittance of OD6 is 10⁻⁴%, and the blocking rate is as high as99.9999%(999999 parts per million). There is no direct correspondence between the OD number and the blocking percentage; you must convert using 100·10⁻ᴼᴰ.
Does the nominal OD apply across the whole wavelength range?
No. The OD of laser safety glasses and filters is specified atspecific wavelengths/bands(e.g. 190~400 nm OD7+); outside the protected band it may be almost fully transmitting. When selecting, you must check the OD at your own laser wavelength and the VLT (visible light transmittance).
The higher the incident power, the lower the transmittance?
For linear materials below the damage threshold, the transmittance T is an intrinsic property of the material and is independent of incident power: P_out always equals P_in×T. But once the power density exceeds the LIDT, the material may bleach, ablate or even break down, and the OD fails instantly.
Are dB and OD two unrelated metrics?
They differ only by a fixed factor: Atten(dB) = −10·OD. OD1 = −10 dB, OD3 = −30 dB, OD6 = −60 dB. Fibre communications conventionally use dB, while filters/protective eyewear use OD; after conversion they can be compared directly.
💡 Common applications
📋 Frequently asked questions
🔗 Related optical tools
Soar Laser | Hotline: 15927220467 | Results are for selection reference only; for actual safe use, please refer to the component datasheet and laser safety standards.


