Description
Product Overview
PFA51505 is an active isolation breadboard support frame for a 750 x 900 mm (30 in x 36 in) breadboard. The frame is 700 mm (27.5 in) tall, rated to 700 kg (1,545 lbs), and supported at four points by independent, air mounted, active vibration isolators. Leveling is pneumatic and self-acting, repeating to ±0.25 mm (0.010 in) after a disturbance. The vertical resonant frequency is below 1.6 Hz and the horizontal resonant frequency is below 1.2 Hz, so the isolated band begins just above those corners. Construction is all steel. Leveling pads provide ±9.5 mm (±0.375 in) of height adjustment and the leveling feet provide ±5 mm (±0.2 in). The PWA061 caster set is available as an option. Continuous pressurised air is required.
750 x 900 mm is the size that appears most often under a single femtosecond laser workstation. Not because the equipment is heavy or numerous, but because of what a femtosecond experiment does with distance. An oscillator, an amplifier stage, a pulse compressor, a stretcher, a delay line and a diagnostic arm do not sit side by side; they sit in a sequence, and the beam has to travel between them in free space because that is how the components are built. The tabletop is therefore sized by metres of beam path, and the beam path is decided long before anyone counts instruments.
That gives a clean rule for this frame: choose it by path length, not by equipment count. A 3 m path fits comfortably on 750 x 900 mm with four straight runs and three folds. The same 3 m path on a 750 x 750 mm table needs five runs and four folds, because the clear span drops from roughly 800 mm to roughly 650 mm. One extra fold is one extra mirror, one extra alignment, one extra reflection loss and one extra surface that can send a stray reflection back into the oscillator. On a femtosecond system that last point is not cosmetic.
The arithmetic is worth putting in front of a buyer because it changes the decision. Each fold costs about 3 percent of throughput at normal incidence with a standard dielectric mirror, so four folds leave 88.5 percent of the light and six folds leave 83.3 percent. Those are small numbers on their own. What makes them matter is that they compound with the alignment budget: every fold mirror is a two-axis adjustment with drift, and the far-field pointing error of a folded path grows with the number of folds. A layout with three folds holds alignment for months; a layout with seven folds needs attention weekly.
The second reason this size is common is the working width. At 750 mm across, a person standing at the long edge can reach 375 mm to the centreline without stretching, and two people can work at the two short ends without colliding. That is the geometry of a one-operator experiment with an assistant, which is what a femtosecond lab usually is. The 900 mm dimension gives enough length for an oscillator at one end, an amplifier chain in the middle and a diagnostics bench at the other end, with roughly 300 mm per stage.
The isolation specification itself is the same across the PFA range because the isolators are the same: 700 kg capacity, 1.6 Hz vertical, 1.2 Hz horizontal, pneumatic self-leveling to ±0.25 mm, all-steel frame, and a dual chamber damped pneumatic spring in the vertical direction working with a trifilar suspension system in the horizontal direction. What this page adds to that common ground is the sizing logic: how much tabletop a given beam path needs, and what a fold actually costs.
Key Features
- 750 x 900 mm working outline with a clear span of about 800 mm along the long axis. That span is the number that decides the fold count, and it is the reason this model sits between the compact 750 x 750 mm bench and the long 750 x 1200 mm bench.
- Four independent, air mounted, active vibration isolators, each carrying 175 kg (386 lbs) at the 700 kg rating. Independent mounting means a fault at one corner shows as a tilt that the leveling valve reports, not as a silent reduction in isolation.
- Vertical resonant frequency below 1.6 Hz and horizontal resonant frequency below 1.2 Hz. On a femtosecond experiment the relevant floor noise is footfall, door closure, pump rotation and building services, all of which sit above these corners and therefore inside the attenuated band.
- Dual chamber damped pneumatic spring for the vertical direction. The tabletop rides on air pressure, the piston is sealed by a rolling rubber diaphragm that permits near frictionless vertical travel while blocking horizontal movement, and air forced through a high damping orifice between the two chambers shortens settling time. The chamber volume ratio is chosen for low resonant frequency and usable damping together.
- Trifilar suspension system for the horizontal direction. The vertical isolators rest on a three-wire pendulum, gravity provides the restoring force, and an oil-free damper between each isolator base and the outer housing suppresses oscillation at the horizontal resonant frequency. No hydraulic fluid is involved anywhere in the frame.
- Pneumatic self-leveling with ±0.25 mm (0.010 in) repeatability. A three-way valve senses tabletop height and adjusts chamber pressure until the tabletop returns to its set point, so adding a delay line or removing a sample holder does not require a manual re-level.
- Sturdy all-steel construction, which matters for a femtosecond bench because the frame is also the thermal reference. Steel has the mass to anchor the pendulum and the dimensional stability to keep the mounting plane flat while the room temperature moves by a degree or two.
- Height adjustment in two ranges: ±9.5 mm (±0.375 in) on the leveling pads for working height and floor slope, ±5 mm (±0.2 in) on the leveling feet for local floor unevenness. The 700 mm (27.5 in) frame height sets a breadboard top that suits a seated operator, and an 800 mm (31.5 in) version of the same frame is available for standing work.
- Optional PWA061 caster set for repositioning the frame between experiments. Casters are for moving; the frame measures on its pads or feet.
- Continuous pressurised air required. If the supply is interrupted the tabletop settles onto its supports and the frame behaves as a rigid steel structure until pressure returns.
- -34 dB at 10 Hz, which is 98 percent isolation, against the roughly 3 percent of throughput that a single fold costs at 97 percent reflectivity. The isolation does not return light to the beam, but it does return time: a bench that settles in a fraction of a second is a bench on which a fold can be optimised instead of waited out.
- -18 dB at 5 Hz and 87.5 percent isolation there, which covers the footfall of the operator standing at the bench while aligning a fold on a bench this short. On a 750 x 900 mm outline the operator is close to the optics, so their own footsteps are part of the disturbance budget.
Technical Specifications
Manufacturer specifications for this model are listed below. The isolation figures are properties of the isolator design and are therefore identical across every breadboard size in the PFA range; only the outline, the clear span and the number of support points per unit area change from one model to the next.
| Parameter | Specification |
|---|---|
| Ordering code | PFA51505 |
| Product class | Active isolation breadboard support frame |
| Breadboard size accepted | 750 x 900 mm (30 in x 36 in) |
| Frame height | 700 mm (27.5 in); an 800 mm (31.5 in) version is also available |
| Load capacity | 700 kg (1,545 lbs), total including breadboard and fixtures |
| Isolator configuration | Four independent, air mounted, active vibration isolators |
| Leveling method | Pneumatic self-leveling, three-way valve, no electronics |
| Leveling repeatability | ±0.25 mm (0.010 in) |
| Vertical resonant frequency | below 1.6 Hz |
| Horizontal resonant frequency | below 1.2 Hz |
| Transmissibility at resonance, vertical axis | below 13 dB |
| Transmissibility at resonance, horizontal axis | below 8 dB |
| Transmissibility at 5 Hz, vertical | -18 dB (87.5%) |
| Transmissibility at 5 Hz, horizontal | -18 dB (87.5%) |
| Transmissibility at 10 Hz, vertical | -34 dB (98%) |
| Transmissibility at 10 Hz, horizontal | -34 dB (98%) |
| Vertical isolation element | Dual chamber, damped pneumatic spring with rolling diaphragm |
| Horizontal isolation element | Trifilar suspension system with oil-free damper |
| Structure | All-steel construction, welded tubular frame |
| Finish | Black Paint |
| Height adjustment, leveling pads | ±9.5 mm (±0.375 in) |
| Height adjustment, leveling feet | ±5 mm (±0.2 in) |
| Isolator height adjustment range | ±6 mm (0.25 in) |
| Leg height adjustment range | ±10 mm (0.4 in) |
| Breadboard height range of the complete system | 26 mm (1.02 in) |
| Optional mobility | PWA061 caster set, ordered separately |
| Air supply | Continuous source of clean, dry, regulated pressurised air |
| Air pressure required at the inlet | 690 kPa (100 psi) maximum |
| Behaviour without air | Tabletop settles onto its supports; rigid frame |
| Largest breadboard the family supports | 1200 x 1800 mm (48 in x 72 in), not applicable to this model |
Bracketed percentages are isolation, not transmission: -34 dB corresponds to about 2.0 percent transmitted, hence 98 percent removed, and -18 dB to about 12.6 percent transmitted, hence the 87.5 percent the datasheet quotes. The ±9.5 mm and ±5 mm figures in the Features list belong to the leveling pads and leveling feet, while the ±6 mm and ±10 mm rows above are the isolator and leg travel limits; these are different parts, and selection follows the table. 26 mm is the breadboard height range of the whole system. Corner frequencies are limits, below 1.6 Hz and below 1.2 Hz.
The next two tables are derived, not published. They answer the question this page exists to answer: how much beam path fits on 750 x 900 mm, and what does each fold cost. The first assumes a 50 mm margin at each end of the long axis for mirror mounts and beam clearance, which leaves an 800 mm clear span, and it compares the result with the same path on the 750 x 750 mm and 750 x 1200 mm outlines.
| Total Beam Path | 750 x 900 mm (800 mm span) | 750 x 750 mm (650 mm span) | 750 x 1200 mm (1100 mm span) |
|---|---|---|---|
| 2.0 m | 3 runs, 2 folds | 4 runs, 3 folds | 2 runs, 1 fold |
| 3.0 m | 4 runs, 3 folds | 5 runs, 4 folds | 3 runs, 2 folds |
| 4.0 m | 5 runs, 4 folds | 7 runs, 6 folds | 4 runs, 3 folds |
| 5.0 m | 7 runs, 6 folds | 8 runs, 7 folds | 5 runs, 4 folds |
Read the middle two columns against each other. For a 3 m path, 750 x 900 mm saves one fold compared with 750 x 750 mm. For a 4 m path it saves two. For a 5 m path it saves one, because the step sizes do not divide evenly into every path length. The saving is real but it is not monotonic, which is why the fold count should be calculated for the actual path rather than estimated from the tabletop area.
The second derived table converts fold count into throughput. A standard dielectric fold mirror at normal incidence reflects about 97 percent, so the cumulative transmission after n folds is 0.97 raised to the power n. The values below are the result of that calculation.
| Fold Count n | Cumulative Transmission 0.97^n | Practical Reading |
|---|---|---|
| 0 | 100.0 percent | Straight line only; needs a 3 m table |
| 1 | 97.0 percent | One fold, minimal alignment risk |
| 2 | 94.1 percent | Comfortable on 750 x 1200 mm |
| 3 | 91.3 percent | The normal case for a 3 m path on 750 x 900 mm |
| 4 | 88.5 percent | Upper practical limit for a femtosecond amplifier chain |
| 5 | 85.9 percent | Alignment maintenance becomes routine |
| 6 | 83.3 percent | Layout is fighting the tabletop |
| 7 | 80.8 percent | One fifth of the light lost to folding alone |
| 8 | 78.4 percent | Rework the layout rather than add mirrors |
Two caveats belong with that table. First, the 97 percent figure is a representative value for a good dielectric mirror at normal incidence and the design wavelength; broadband ultrafast mirrors are usually lower, and a mirror specified for 800 nm will not deliver the same number at 400 nm. Second, the table counts only reflection loss. It does not count the group delay dispersion that each fold mirror adds, which matters when the pulse is short enough for the mirror coating to contribute to the chirp budget.
Applications
The applications below are the ones where 750 x 900 mm is the natural fit rather than a stretch. In each case the tabletop is chosen because a metre-scale beam path has to be laid out in free space, and because the experiment is run by one person or by one person with an assistant.
- A single laser experiment station. One source, one sample position, one or two detectors, and a beam path of two to three metres. The 750 x 900 mm outline holds the source at one end, the interaction region in the middle and the detection at the other end without stacking anything vertically.
- Femtosecond oscillator and amplifier chain. The oscillator, the stretcher, the amplifier stage, the compressor and the pulse diagnostic form a sequence that cannot be shortened without redesigning the system. This is the canonical 750 x 900 mm layout, and it is where the fold-count arithmetic on this page was aimed.
- Teaching and demonstration benches for ultrafast optics. A mode-locked oscillator, an autocorrelator and a spectrometer make a complete teaching experiment that fits inside one square metre. The all-steel frame survives being moved between teaching sessions, and the self-leveling valve means the bench comes back to level after being wheeled across a corridor.
- A small measurement system that needs its own isolation. Optical coherence tomography, confocal sensing, a laser Doppler vibrometer or a heterodyne interferometer with a short reference arm. These do not need a three-metre path, but they do need to be off a shared bench, and 750 x 900 mm is the smallest outline that holds the optical train without crowding.
- A pump-probe arm added to an existing laboratory. Where a larger bench already carries the main experiment, a second frame of this size gives the delay line and the probe arm their own isolated surface, which is often cheaper than rebuilding the main bench to make room.
- Laser stabilisation and locking electronics bench. A reference cavity, a beat-detection setup and a wavemeter need isolation and a modest footprint. The 700 mm frame height puts the optics at seated eye level for alignment work that requires looking along the beam.
Selection Guide
This frame is sized by beam path, so the selection procedure starts with a sketch of the optical layout rather than with a list of equipment. Work through the steps below in order; the first two produce a number, and the rest test whether that number is achievable in the room.
- Draw the beam path and measure it. Sketch the route from source to detector, including every pass through a delay line, every pass through a multi-pass amplifier cell, and every diagnostic tap. Add the segments up. A Ti:sapphire oscillator followed by a multipass amplifier and a compressor, with the beam folded back and forth three or four times, routinely reaches 3 m before any diagnostic is added.
- Divide by the clear span and round up. On 750 x 900 mm the clear span is about 800 mm after allowing 50 mm at each end for mounts. A 3 m path needs four runs. A 4 m path needs five. Round the result up, then subtract one to get the fold count.
- Test the fold count against the transmission budget. Three folds is comfortable. Four is the practical limit for an amplifier chain where seed power is precious. Five or more means the layout is being forced, and the honest options are a longer tabletop or a redesign that shortens the path.
- Check the fold pitch. Four runs across a 750 mm width put the parallel beam lines 187.5 mm apart. That is enough for a 25 mm mirror in a standard mount with clearance, but it leaves little room for a delay line stage or a beam sampler between adjacent lines. Five runs reduce the pitch to 150 mm, and seven runs to 107 mm, at which point mounts begin to interfere.
- Confirm the mass against the 700 kg rating. A femtosecond workstation is usually lighter than people expect: an oscillator, an amplifier head, a compressor and a few translation stages typically total well under 200 kg. Add the breadboard, add 20 to 30 percent for future additions, and compare with a working budget of 490 kg to 560 kg. The rating is rarely the binding constraint at this size.
- Check the centre of gravity, briefly. At 750 mm width the frame is more forgiving than the 750 mm square model, but a tall riser carrying a compressor or an enclosure above the table still raises the centre of gravity. Keep heavy items on the breadboard and steer the beam upward with a periscope rather than lifting the source.
- Choose 700 mm or 800 mm frame height. 700 mm suits seated alignment work. 800 mm suits standing work and taller instrumentation. The isolation performance is identical; the difference is ergonomics and, marginally, the height of the centre of gravity above the floor.
- Decide on casters and confirm the air supply. Order the PWA061 set if the bench will move. Confirm that a clean, dry, regulated air line can reach the installation position and stays pressurised for the duration of an experiment.
Series Comparison
All six frames in the PFA range share the isolator design, the 700 kg rating, the 700 mm height and the 1.6 Hz and 1.2 Hz resonant frequencies. The choice between them is a choice of clear span, and clear span converts directly into fold count. The table below is ordered by span so that the comparison is about the number that matters.
| Model | Breadboard Size | Clear Span | Area (m²) | 3 m Path Needs | Typical Role |
|---|---|---|---|---|---|
| PFA51509 | 750 x 750 mm (30 x 30 in) | 650 mm | 0.5625 | 5 runs, 4 folds | Smallest bench, one setup |
| PFA51505 | 750 x 900 mm (30 x 36 in) | 800 mm | 0.6750 | 4 runs, 3 folds | Single workstation, one operator |
| PFA51508 | 750 x 1200 mm (30 x 48 in) | 1100 mm | 0.9000 | 3 runs, 2 folds | Long straight path, fewest folds |
| PFA51507 | 900 x 1200 mm (36 x 48 in) | 1100 mm | 1.0800 | 3 runs, 2 folds | Two stations, shared centre lane |
| PFA51502 | 900 x 1500 mm (36 x 60 in) | 1400 mm | 1.3500 | 3 runs, 2 folds | Multi-station large bench |
| PFA51504 | 1200 x 1500 mm (48 x 60 in) | 1400 mm | 1.8000 | 3 runs, 2 folds | Largest outline, room-scale base |
The fold count column stops improving at three runs for a 3 m path, and that is the useful lesson in the table. Once the clear span passes about 1000 mm, a 3 m path needs three runs on any of the larger frames, so paying for 1200 mm or 1500 mm of length buys nothing for that particular path. What the larger frames buy is the ability to hold longer paths, more stations, or two people working at once. If the layout is one workstation with a 3 m path, 750 x 900 mm is where the curve flattens out.
The width dimension separates the models in a different way. The 750 mm wide frames give 187.5 mm of fold pitch at four runs and 150 mm at five, which is comfortable for a single row of mounts. The 900 mm and 1200 mm wide frames give more pitch and allow a centre lane for a shared beam or for cable routing, which is what makes two-station layouts practical. That is a different argument from fold count and it is treated on the pages for those models.
FAQ
Why not simply buy a larger bench and have room to spare?
Because a larger bench changes the room, not just the experiment. A 1200 mm or 1500 mm frame needs a wider access route, a larger floor area, more air flow and a second person to install, and it costs more than the fold count saving is worth for a single workstation. The rule of thumb is to buy the smallest outline that keeps the fold count at three or four, and for a 3 m femtosecond path that is 750 x 900 mm.
How much does one fold really cost?
About 3 percent of throughput at normal incidence with a standard dielectric mirror, so four folds leave 88.5 percent and six folds leave 83.3 percent. The optical loss is the smaller part of the cost. The larger part is that each fold adds a two-axis alignment, a drift path and a surface that can reflect light back toward the oscillator, which on a femtosecond system can destabilise mode locking or damage a component.
Does the 750 mm width limit the beam height?
No. The width sets the fold pitch, not the beam height. At four runs across 750 mm the parallel beam lines sit 187.5 mm apart, which is comfortable for 25 mm mirrors in standard mounts. At seven runs the pitch drops to 107 mm and adjacent mounts start to interfere. If a layout needs many parallel passes, the width becomes the constraint before the length does.
Can a femtosecond laser be mounted directly on this frame?
Yes, and it should be, provided the breadboard is a proper damped optical breadboard and the laser sits over the centre of the four support points rather than at a corner. A femtosecond oscillator is a compact, moderately heavy item, and putting it low on the breadboard is better for stability than putting it on a shelf or a riser above the table.
What is the difference between the 700 mm and 800 mm versions?
Only the frame height. The isolators, the load rating, the resonant frequencies and the leveling behaviour are identical. 700 mm (27.5 in) gives a breadboard top that suits a seated operator at a standard chair; 800 mm (31.5 in) suits standing work. Because the centre of gravity is measured from the floor, the taller version raises it by 100 mm for the same payload, which is a small but real effect on stability.
Is the isolation good enough for a mode-locked oscillator?
The frame attenuates floor motion above 1.6 Hz vertically and 1.2 Hz horizontally, which covers footfall, door closure, pump rotation and most building services. It does not remove acoustic coupling, air currents or vibration generated on the breadboard itself, so an oscillator that is sensitive to those will still need an enclosure and a cover. Isolation and acoustic enclosure solve different problems and are usually needed together.
How does the self-leveling behave when a heavy component is added?
The tabletop dips, the three-way valve senses the change in height, and chamber pressure is adjusted until the tabletop returns to its set point. The return is repeatable to ±0.25 mm (0.010 in). The valve also compensates for a change in load distribution, so adding a delay line at one end does not leave the bench permanently tilted.
What happens if the compressor stops during an experiment?
The tabletop settles onto its supports. Nothing is damaged and the optical alignment is preserved as long as the descent is gentle, but isolation stops and the bench becomes a rigid steel frame. When pressure returns the tabletop lifts and re-levels to within ±0.25 mm, so the experiment can usually continue without realignment. Fit a gauge where the operator can see it and treat air pressure as a run condition, not a facility detail.
Can the frame carry a granite plate instead of a breadboard?
Yes, provided the plate outline matches the frame and the total mass stays inside the 700 kg rating. A granite plate adds mass low down, which is good for stability, but it also adds height and it does not provide the tapped hole grid that optical mounts need. Most femtosecond layouts use a steel honeycomb breadboard with a damped core rather than granite, for exactly that reason.
Does the frame need to be bolted to the floor?
No. The frame stands on its leveling pads and feet, and the pneumatic isolators are designed to work without floor anchors. Bolting would bypass the isolation and is the wrong thing to do. What the floor does need to provide is adequate point loading: at the 700 kg rating each corner carries 175 kg (386 lbs), and on a raised access floor the panel rating should be checked against that.
Usage Precautions
A femtosecond bench is more sensitive to layout discipline than to the isolation hardware, and most of the precautions below are about layout rather than about the frame. They are written for the case where the frame is installed and the optical train is being built on it.
- Plan the fold count before drilling anything. Once a breadboard has a hole pattern, the layout is fixed. Sketch the beam path at full scale, count the folds, and check the fold pitch against the mount footprints. Four runs at 187.5 mm pitch is comfortable; seven runs at 107 mm is not, and the discovery is expensive after the fact.
- Keep the beam height low. Every millimetre of beam height above the breadboard is a millimetre of lever arm on every mount, and a tall periscope is the most common way a well-chosen frame ends up with a stability problem. Where the beam must be raised, raise it with a short periscope near the point of use rather than carrying the whole path at height.
- Route the return beam deliberately. A folded path sends light in both directions, and a fold mirror at normal incidence will return a fraction of the beam toward the source. On an amplifier chain that is a route to feedback damage. Angle the folds slightly off normal where the layout allows, use an isolator at the source, and keep beam dumps at the ends of every unused path.
- Provide clean, dry, regulated air. Moisture damages the diaphragm and the leveling valve, and particulate blocks the damping orifice. Fit a filter-regulator at the frame inlet, drain it regularly, and take the required pressure and flow from the installation manual for the exact model rather than inferring them from the load rating.
- Level mechanically before pressurising. Set the frame roughly level on its pads and feet, then bring up air pressure and let the valve finish. Starting from a badly out-of-level frame uses up the ±9.5 mm pad travel and the ±5 mm foot travel on a bias that the valve then has to work against.
- Do not measure on casters. If the PWA061 set is fitted, lower the frame onto its pads or feet, let the leveling settle, and only then take data. Casters add a compliant second contact with the floor and the leveling system has no defined set point while the frame is rolling.
- Keep the optical table covered when idle. Dust on fold mirrors is the main cause of gradual throughput loss on a folded path, and the loss is easy to attribute to the laser rather than to the optics. Covers also reduce air-current-induced beam wander.
- Check the floor and the access route first. A 750 x 900 mm frame passes a standard 900 mm door, but the route needs checking for turns and lifts. Each corner carries 175 kg at rating, so a raised floor needs its panel rating confirmed and spreader plates may be needed.
- Allow the bench to settle after any change. After adding mass, moving the frame or reconnecting air, give the leveling system time to settle and the breadboard time to stop ringing before recording data. A femtosecond interferometer will show the difference.
Disclaimer
Specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence. The manufacturer may revise specifications without notice.
The path-length, fold-count and transmission tables are calculations, not manufacturer data. They rest on stated assumptions: a 50 mm margin at each end of the long axis, a 97 percent reflectivity per fold mirror at normal incidence, and a straight-line segment per run. Real layouts lose additional path to mirror footprints, beam samplers and delay stages, and real ultrafast mirrors often reflect less than 97 percent at the wavelength of interest. Use the tables to compare sizes, not to predict absolute throughput.
Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the installed payload, the floor and the quality of the air supply. No transmission curve for the isolation system is reproduced here; where a project requires a specific isolation performance at a specific frequency, request current performance data for the exact configuration.
No price is stated on this page. Availability, lead time and price are confirmed at the time of enquiry and may change with stock and currency. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.
Contact Us
For a quotation on PFA51505, or for help confirming that 750 x 900 mm holds a particular beam path, send a sketch or description of the optical layout with the total path length, the number of folds you expect, the estimated total mass including the breadboard, and confirmation that a continuous air supply is available at the installation position. With those four items the model can be confirmed and any layout problem flagged before the order is placed.
For projects that combine the frame with a breadboard, a granite plate or the PWA061 caster set, send the whole requirement in one message so that the mounting interface, the assembled working height and the access route can be checked together. For an existing laboratory, include the door width on the route, the floor construction and whether the bench will be moved between experiments.








Reviews
There are no reviews yet.