QQ: 859818709

Thorlabs PF07-03-M02 Ø19.0 mm MIR-Enhanced Gold Mirror, 2-20 µm

Thorlabs PF07-03-M02 Ø19.0 mm MIR-Enhanced Gold Mirror, 2-20 µm

Price on request
Category:

Description

Product Overview

The Thorlabs PF07-03-M02 is a Ø19.0 mm mid-infrared enhanced gold mirror on a 6.0 mm fused silica substrate, specified from 2 to 20 µm with 98% average reflectance and 95% absorption-weighted reflectance at angles of incidence from 0 to 45 degrees. The clear aperture is Ø17.1 mm, the overcoat is qualified to MIL-C-48497A, and the part shares its substrate, thickness and mounting with the rest of the 19 mm group.

What makes it different is that the coating stack, not the metal, is doing the work. Gold on its own reflects well across the infrared, but it is a soft bare metal that cannot be touched. The enhanced coating adds a dielectric design that Thorlabs states performs better than unprotected gold in the mid-infrared while resisting physical damage, and the same coating is offered on the concave mirrors used to build Herriott cells for gas sensing. In other words it was designed around a specific application, mid-infrared absorption spectroscopy, rather than being a general-purpose broadband mirror.

That design choice has a price, and Thorlabs is explicit about both halves of it. The overcoat improves performance past 2 µm but causes performance to suffer in the near-infrared spectral region, and the manufacturer directs anyone working below 2 µm to a different metallic coating or to a dielectric. This page therefore treats 2 to 20 µm as a hard window rather than a nominal range: a 1064 nm beam, a 1.5 µm telecom source or a 780 nm diode is outside the specification, not merely suboptimal inside it.

The second limit is power. The published thresholds are 0.1 J/cm² at 1064 nm and 3 J/cm² at 10.6 µm with 100 ns pulses, and 25 W/cm at 1.070 µm and 450 W/cm at 10.6 µm continuous. Set against the protected gold item at 2 J/cm² and 500 W/cm, the pulsed rating at 1.064 µm is twenty times lower and the continuous rating at 1.07 µm is also twenty times lower. This is a low-power mid-infrared optic, and it should not be proposed for a high-energy pulse chain on the strength of its reflectance alone.

Key Features

  • 98% average and 95% absorption-weighted from 2 to 20 µm: the highest mid-infrared reflectance in this group, and the reason to accept its constraints
  • Specified from 0 to 45 degrees angle of incidence: the reflectance holds across the range a folded or off-axis layout actually uses, rather than only at normal incidence
  • MIL-C-48497A overcoat: a qualified durability standard for optical coatings, so the surface can be cleaned and handled in a working instrument
  • Not usable below 2 µm: the overcoat degrades near-infrared performance, and the manufacturer recommends another coating for that band
  • Low damage threshold by comparison: 0.1 J/cm² at 1064 nm and 25 W/cm continuous at 1.070 µm, roughly one tenth to one twentieth of the protected gold ratings
  • Ø19.0 mm with Ø17.1 mm clear aperture: the clear aperture is stated directly rather than as a percentage, which matters when the beam is deliberately oversized

Technical Specifications

Model PF07-03-M02
Coating Mid-infrared enhanced gold
Overcoat Dielectric, MIL-C-48497A qualified
Wavelength range 2 µm – 20 µm
Average reflectance 98% from 2 to 20 µm at 0 to 45 degrees angle of incidence
Absorption-weighted reflectance 95% over the same range and angles
Substrate Fused silica
Diameter Ø19.0 mm
Diameter tolerance +0.0 mm / -0.1 mm
Thickness 6.0 mm (0.24 in)
Thickness tolerance +/-0.2 mm
Clear aperture Ø17.1 mm
Surface flatness λ/10 peak to valley at 633 nm
Surface quality 40-20 scratch-dig
Parallelism at most 3 arcmin
Pulsed damage threshold 0.1 J/cm² at 1.064 µm (10 ns, 10 Hz, Ø1.06 mm); 3 J/cm² at 10.6 µm (100 ns, 1 Hz, Ø1.29 mm)
CW damage threshold 25 W/cm at 1.070 µm (Ø1.04 mm); 450 W/cm at 10.6 µm (Ø1.18 mm)
Out-of-band use not specified below 2 µm; near-infrared performance is degraded by the overcoat
Source Thorlabs official series specification table

Applications

Everything on this list sits inside 2 to 20 µm and at modest power. If either condition fails, the protected gold mirror is the correct part and this one is not.

  • FTIR and gas-sensing benches: routing the interferometer output through a sample cell to the detector, where 98% across the whole fingerprint region keeps the signal budget intact
  • Quantum cascade and interband cascade laser systems: steering a 4 to 12 µm QCL or ICL through a multipass cell, a configuration Thorlabs designed this coating for
  • Mid-infrared thermal imaging: relaying a 3 to 5 µm or 8 to 12 µm scene to a focal plane array without a wavelength-dependent throughput that would need radiometric correction
  • Mid-infrared supercontinuum routing: a broadband 2 to 10 µm source where a coating with an absorption feature would imprint structure on the spectrum
  • Low-power 10.6 µm probing: pilot beams and detection paths around a CO2 process, where the 450 W/cm rating at 10.6 µm is ample but the main process beam is not routed through this optic

Selection Guide

  • Confirm the band before anything else: if any part of the beam is below 2 µm, this is the wrong mirror. A 2 µm band edge means a 1.9 µm source is outside it, and a mixed 1.5 µm and 4 µm path needs two different optics
  • Do the power calculation with the lower numbers: 25 W/cm continuous at 1.07 µm and 0.1 J/cm² pulsed at 1064 nm are the figures to use. Anyone proposing this mirror for a Q-switched pulse chain should be shown the protected gold page first
  • Exploit the 45 degree specification: unlike coatings characterised only near normal incidence, this one is specified across 0 to 45 degrees, so an off-axis fold does not require a derating calculation
  • Use the stated clear aperture: Ø17.1 mm is given directly. For a beam that is deliberately oversized to average out fringes in an FTIR bench, that is the number to design around, not 90% of 19 mm
  • Consider the Herriott cell family: if the application is a multipass gas cell, the same coating is available on concave mirrors designed for that geometry, which keeps the whole cell on one coating and one calibration

Series Comparison

Read this table as a map of where the mid-infrared coating sits relative to the alternatives, with the two constraints in their own columns rather than buried in a note.

Item Coating Wavelength range Average reflectance Clear aperture Best use
PF07-03-M02, this page MIR-enhanced gold 2 – 20 µm 98% average, 95% absorption-weighted Ø17.1 mm Low-power mid-infrared sensing and imaging
PF07-03-M01 Protected gold 800 nm – 20 µm 96% about Ø17.1 mm Broadband infrared at high power
PF07-03-P01 Protected silver 450 nm – 2 µm; 2 – 20 µm 97% / 95% about Ø17.1 mm Visible and near-infrared throughput
PF07-03-G01 Protected aluminium 450 nm – 2 µm; 2 – 20 µm 90% / 95% about Ø17.1 mm General broadband folding at low cost

Smaller versions of the same coating are available for compact gas cells: Ø1/2 inch mid-infrared enhanced gold and Ø7.0 mm mid-infrared enhanced gold.

FAQ

Can this mirror be used at 1064 nm? No. The coating is specified from 2 µm, and Thorlabs states that the overcoat causes near-infrared performance to suffer. A 1064 nm beam on this optic is outside the specification and will not deliver the reflectance the number on the page implies. Use the protected gold or protected silver item.

Why is the damage threshold so much lower than the protected gold mirror? Because the dielectric stack is optimised for reflectance in the mid infrared, not for laser hardness. The published figures are 0.1 J/cm² at 1064 nm and 25 W/cm continuous at 1.070 µm, against 2 J/cm² and 500 W/cm for the protected gold coating. The two properties trade against each other in thin-film design, and this coating took the reflectance.

What is the difference between the 98% and the 95% figure? The first is average reflectance across 2 to 20 µm; the second is absorption-weighted reflectance over the same band. The absorption-weighted number accounts for where the coating absorbs rather than treating every wavelength equally, so it is the more honest figure for a spectroscopic application where the signal depends on throughput at specific lines.

Is 45 degrees angle of incidence within specification? Yes. The coating is specified from 0 to 45 degrees, so a fold at 45 degrees needs no derating. That is unusual: many infrared coatings are characterised near normal incidence and lose reflectance at the angles a real layout uses.

What does the MIL-C-48497A qualification mean in practice? It is a United States military specification for the durability of optical coatings, covering adhesion, abrasion and humidity exposure. In practice it means the surface can be cleaned with a standard solvent procedure and will survive handling in a working instrument, rather than being treated as a delicate bare-metal film.

Usage Precautions

  • Never let the band drift below 2 µm: a laser swap from a 4 µm QCL to a 1.5 µm source leaves this mirror in place and silently out of specification. Label the optic or record the band in the build documentation
  • Budget the power against 25 W/cm and 0.1 J/cm²: these are the lowest ratings in the group. A focused continuous beam of a few watts in a 1 mm spot already reaches roughly 400 W/cm and will damage the coating
  • Clean according to the MIL spec, not by habit: blow off grit, then solvent on a tissue with a single-direction drag. The overcoat tolerates this; dragging dry tissue does not
  • Keep water away from the coating edge: mid-infrared instruments are often purged and sometimes humidified. Condensation at the rim of the coating is where delamination begins
  • Match the mount to the 6 mm substrate: the flexure arm of a Polaris mount contacts the mirror at three points. A mount that clamps on the rim of a 6 mm disc bends it, and in an interferometer that appears as fringes that will not settle
  • Do not substitute it for a process optic: the 450 W/cm rating at 10.6 µm covers a pilot beam or a detection path, not a cutting or welding beam. Route the process beam through a copper or protected gold mirror

Disclaimer

Specifications on this page are compiled from Thorlabs official published material and are provided as a selection reference. The current official specification sheet governs; specifications and appearance may change without notice. Price and lead time are quoted by our sales team on request.

Contact Us

Changsha Soar Laser Equipment Co., Ltd. supports mid-infrared system builders with coating selection, multipass cell optics and lead-time information. Call +86 159 2722 0467, email 859818709@qq.com, or browse www.soar-laser.cn.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PF07-03-M02 Ø19.0 mm MIR-Enhanced Gold Mirror, 2-20 µm”

Your email address will not be published. Required fields are marked *

中文EN