QQ: 859818709

Thorlabs PFA51504 Active Isolation Breadboard Support Frame, 700 mm Height, 1200 x 1500 mm

Thorlabs PFA51504 Active Isolation Breadboard Support Frame, 700 mm Height, 1200 x 1500 mm

Price on request
Category:

Description

Product Overview

PFA51504 is the largest frame in the PFA range, an active isolation breadboard support frame for a 1200 x 1500 mm (48 in x 60 in) breadboard. It is 700 mm (27.5 in) high, rated to 700 kg (1,545 lbs), and stands on four independent, air mounted, active vibration isolators that level themselves pneumatically to ±0.25 mm (0.010 in) repeatability. The vertical resonant frequency is below 1.6 Hz, the horizontal resonant frequency is below 1.2 Hz, and the construction is all steel. Leveling pads provide ±9.5 mm (±0.375 in) of adjustment and the leveling feet provide ±5 mm (±0.2 in). The PWA061 caster set is optional and a continuous supply of pressurised air is required.

With a frame this size, the optical design is usually the easy part. By the time a laboratory is considering a 1.8 m² isolated surface it already knows what it wants to put on it, and the experiment has probably been running on a smaller bench for a year. The specification that decides whether the project succeeds is not written anywhere on the product page, because it is a property of the building: can the frame get in, can the floor carry it, and can the air supply reach it.

This is not a hypothetical risk. Large isolation benches fail on site far more often than they fail optically. The frame arrives on a lorry, and the route between the lorry and the laboratory turns out to include a 900 mm door, a 90 degree corridor corner, a lift with a 1000 mm opening and a raised floor whose panels are rated for a person and a trolley. None of these constraints appears on a layout drawing, and every one of them can stop an installation on the delivery day, when the crate is already on the ground and the crane has gone.

The geometry is worth stating precisely because it explains the difficulty. The 1200 x 1500 mm outline has a diagonal of 1920.9 mm. A frame cannot be carried flat through an opening narrower than its 1200 mm side, and it cannot be turned through a corner without swinging that 1920.9 mm diagonal. Adding 100 mm of handling clearance on each side of the diagonal gives a required swept envelope of about 2062 mm. That number, not the 1200 mm width, is what determines whether a particular corridor works.

The second site constraint is load. The 700 kg rating is a total, and it includes the breadboard. A 1200 x 1500 mm breadboard is itself a substantial item, so the payload budget is the rating minus the tabletop mass: with a 150 kg tabletop the budget is 550 kg, with a 200 kg tabletop it is 500 kg, and with a 250 kg tabletop it is 450 kg. Applying a 20 to 30 percent margin on the total brings the working figure down to between 490 kg and 560 kg before any equipment is counted. On the largest frame in the range, the arithmetic that matters is subtraction, not addition.

The isolation itself is the same as on every other size in the PFA range, because the isolators are the same components: a dual chamber damped pneumatic spring vertically, a trifilar suspension system horizontally, 1.6 Hz and 1.2 Hz corners, pneumatic self-leveling, all-steel construction. What this size adds is area and base, which is what makes a multi-station or whole-room installation possible. What it also adds is a set of logistics problems that smaller frames do not have.

Key Features

  • 1200 x 1500 mm (48 in x 60 in) outline, 1.8 m² of surface and the largest breadboard size in the range. It is 1.3333 times the area of the 900 x 1500 mm frame, which is the difference between a multi-station bench and a whole-room isolation base.
  • A 1920.9 mm diagonal, which is the number that governs how the frame can be moved. Doors, corridor corners and lift openings should be checked against the swept envelope of about 2062 mm that this diagonal implies with handling clearance, not against the 1200 mm width alone.
  • 700 kg (1,545 lbs) total capacity, 175 kg (386 lbs) per isolator at rating. On a bench this large the capacity is usually adequate, but the total includes the breadboard, so the payload budget has to be calculated rather than assumed.
  • Four independent, air mounted, active vibration isolators with pneumatic self-leveling to ±0.25 mm (0.010 in). Independent mounting means the leveling valve trims residual tilt across a 1.8 m² surface rather than relying on the frame being perfectly rigid.
  • Vertical resonant frequency below 1.6 Hz and horizontal resonant frequency below 1.2 Hz. The isolated band starts just above those corners, which places footfall, door closure, pump rotation and building services inside the attenuated region.
  • Dual chamber damped pneumatic spring in the vertical direction. Air pressure supports the tabletop, a rolling rubber diaphragm seals the piston to the upper chamber and permits near frictionless vertical travel while blocking horizontal motion, and air forced through a high damping orifice between the chambers damps the oscillation and shortens settling time. The chamber volume ratio is optimised for low resonant frequency and usable damping together.
  • Trifilar suspension system in the horizontal direction. The vertical isolators rest on a three-wire pendulum, gravity supplies the restoring force, and an oil-free damper between each isolator base and the outer housing suppresses oscillation at the horizontal resonant frequency. No hydraulic fluid is used.
  • Sturdy all-steel construction. Across 1.8 m² the frame has to hold a large mounting plane flat while the room temperature moves, and steel provides both the stiffness and the thermal mass to do it.
  • Height adjustment of ±9.5 mm (±0.375 in) on the leveling pads for working height and floor slope, and ±5 mm (±0.2 in) on the leveling feet for local floor unevenness. The 700 mm (27.5 in) height is standard for the range and an 800 mm (31.5 in) version is available for standing work.
  • Optional PWA061 caster set. On a frame this size the casters are useful for final positioning within a room, but the frame should be moved on a pallet or a trolley for any distance, and it should measure on its pads or feet.
  • Continuous pressurised air required. Without air the tabletop settles onto its supports and the frame behaves as a rigid steel structure until pressure returns.
  • -18 dB at 5 Hz on both axes, which is 87.5 percent of the floor motion removed at the frequency that matters in an occupied building. Foot traffic in a corridor, a door closing two rooms away and a lift starting in the core all land in the three to eight hertz band, and this is the figure that covers them rather than the headline number at ten hertz.
  • -34 dB at 10 Hz and 98 percent isolation there, so the residual motion at the table top is about one fiftieth of the floor. On a frame this large the alternative to that figure is a structural survey and a separate foundation, which is rarely available in an existing building.
  • A bounded resonant peak of below 13 dB vertically and below 8 dB horizontally, so the frame does not turn a low frequency floor into a worse one before it starts helping. A frame with a high peak is the reason some laboratories conclude that isolation made their measurement noisier.

Technical Specifications

The manufacturer specifications below apply to this model. The isolation values are shared with every other size in the range; the outline-specific entries are the breadboard size, the diagonal and the load per isolator.

Parameter Specification Note
Model PFA51504 Largest outline in the PFA range
Product class Active isolation breadboard support frame Support structure, not a breadboard
Breadboard size accepted 1200 x 1500 mm (48 in x 60 in) Four-point support
Diagonal of the outline 1920.9 mm (75.6 in) Derived from the outline dimensions
Frame height 700 mm (27.5 in) 800 mm (31.5 in) version also available
Load capacity 700 kg (1,545 lbs) Total, including the breadboard
Load per isolator at rating 175 kg (386 lbs) 700 kg divided by four
Isolator configuration Four independent, air mounted, active One at each corner
Leveling method Pneumatic self-leveling Three-way valve, no electronics
Leveling repeatability ±0.25 mm (0.010 in) Return to level after a disturbance
Vertical resonant frequency below 1.6 Hz Lower edge of the isolated band
Horizontal resonant frequency below 1.2 Hz Set by the trifilar suspension
Vertical transmissibility at resonance below 13 dB Peak at the corner, not attenuation
Horizontal transmissibility at resonance below 8 dB Lower peak than the vertical axis
Vertical transmissibility at 5 Hz -18 dB (87.5%) 87.5% of the floor motion removed
Horizontal transmissibility at 5 Hz -18 dB (87.5%) The band carrying footfall and doors
Vertical transmissibility at 10 Hz -34 dB (98%) 98% removed, about 2% passes
Horizontal transmissibility at 10 Hz -34 dB (98%) Axes converge above ten hertz
Vertical isolation element Dual chamber, damped pneumatic spring Rolling diaphragm, orifice damping
Horizontal isolation element Trifilar suspension system Gravity restoring force, oil-free damper
Structure All-steel construction Welded tubular frame
Finish Black Paint Painted steel, not plated
Height adjustment, pads ±9.5 mm (±0.375 in) Working height and floor slope
Height adjustment, feet ±5 mm (±0.2 in) Local floor unevenness
Isolators height adjustment range ±6 mm (0.25 in) Pneumatic element travel
Legs height adjustment range ±10 mm (0.4 in) Static trim at the leg
Total height range of the system 26 mm (1.02 in) Breadboard travel, isolators plus legs
Optional mobility PWA061 caster set Ordered separately
Air supply Continuous pressurised air Clean, dry, regulated
Air pressure required 690 kPa (100 psi) maximum Regulated supply at the inlet
Behaviour without air Tabletop settles onto its supports Rigid frame until pressure returns

A note on how to read the transmission rows. A transmissibility in decibels is a ratio, and the figure in brackets is the isolation it represents, not the fraction of vibration that reaches the table. At -34 dB the transmitted motion is about 2.0 percent of the floor motion, so 98 percent has been removed; at -18 dB the transmitted motion is about 12.6 percent, which the datasheet rounds to 87.5 percent removed. Read the rows as attenuation and the numbers are consistent. On height, the two sets of figures refer to different hardware: ±9.5 mm on the leveling pads and ±5 mm on the leveling feet appear in the Features list and describe the static adjusters, while ±6 mm for the isolators and ±10 mm for the legs are the travel limits of the pneumatic elements and the leg structure in the table above. Neither set overrides the other, and the table is the one to size from. The 26 mm figure is the total breadboard height range, combining both. Thorlabs states the corner frequencies as limits, below 1.6 Hz and below 1.2 Hz, which is how they are written above.

The tables that follow are site-survey tools, derived rather than published. The first checks whether a proposed access route can take the frame. It is deliberately conservative: it assumes the frame is carried on edge, because carrying it flat needs a 1200 mm opening plus handling clearance on both sides, and it assumes that a corner requires the diagonal to swing clear.

Opening or Constraint Verdict Basis Comment
800 mm No Narrower than the 1200 mm width Rework the route or remove the frame from the wall
900 mm No Narrower than the 1200 mm width Standard door, cannot pass on edge
1000 mm No Narrower than the 1200 mm width Wide door, still insufficient
1100 mm No Narrower than the 1200 mm width 100 mm short
1200 mm Marginal Exactly the frame width, zero clearance Only with the frame stripped of fittings and two handlers
1300 mm Yes, tight 50 mm clearance each side Workable for a straight run with careful handling
1500 mm Yes 150 mm clearance each side Comfortable for a straight run
Corner turn Needs about 2062 mm Diagonal plus 100 mm each side Measure the free diagonal, not the corridor width

The corner row is the one that catches people out. A corridor can be 1400 mm wide and still fail, because turning a 1921 mm diagonal through a 90 degree corner requires a clear area at the corner roughly equal to the diagonal plus handling clearance. Measure the free diagonal at the tightest corner, with doors open and any furniture or wall-mounted equipment removed, and treat a marginal result as a failure.

The second table is the payload budget. It subtracts the tabletop from the 700 kg total, because on a frame this size the breadboard is a significant fraction of the rating and the published capacity is not the same as the available payload.

Breadboard Mass (example) Remaining Payload Fraction of Rating Comment
120 kg 580 kg 83 percent Light aluminium-core breadboard
150 kg 550 kg 79 percent Typical steel honeycomb breadboard
200 kg 500 kg 71 percent Heavier damped breadboard
250 kg 450 kg 64 percent Thick or granite-topped breadboard
300 kg 400 kg 57 percent Solid granite plate

The example masses are illustrative and should be replaced with the mass of the breadboard actually specified. The pattern is what matters: on the largest frame, a heavy tabletop consumes a third of the rating before a single instrument is mounted, and the 20 to 30 percent growth margin that a laboratory should leave for future equipment has to come out of what remains. The working figure is between 490 kg and 560 kg of total load, which on this outline is easily reached by a multi-station installation.

Floor Figure Metric Imperial Equivalent Basis
Load per corner at rating 175 kg (386 lbs) 1717 N Four-point support
Bearing pressure, 100 x 100 mm pad 171.7 kPa 1.72 kg/cm² Assumes a 100 mm square contact area
Bearing pressure, 120 x 120 mm pad 119.2 kPa 1.19 kg/cm² Assumes a 120 mm square contact area
Share of a 12 m² room 15.0 percent 1.8 m² of 12 m² Floor area taken by the frame alone

The bearing pressure figures depend entirely on the contact area of the pads and feet, which should be taken from the current drawing rather than from this table. They are included because the question a facilities engineer asks is always pressure rather than force, and a frame that is acceptable on a slab can be marginal on a raised access floor once the same load is concentrated into four small contacts.

Applications

A 1.8 m² isolated surface is specified when the experiment cannot be split across benches. The applications below share that property: in each case the value of the frame comes from having one continuous isolated plane under several things at once.

  • A multi-station bench with several experiments on one surface. Three or four stations, each with its own source and detector, sharing one leveling reference and one air supply. The value is not just floor area: it is that all the stations move together when the building moves, so relative alignment between them is preserved.
  • Large interferometry and holography. A reference arm of several metres, a large-aperture test setup or a holographic recording arrangement needs a continuous flat surface longer than any single fold can provide. The 1500 mm dimension is what allows the reference arm to be laid out rather than folded repeatedly.
  • A composite experiment platform requiring whole-surface isolation. Where an optical system, a mechanical stage and an electronic rack all have to sit on the same isolated reference, a single large frame is the only way to guarantee that they share one inertial reference.
  • A single isolation base for an entire small laboratory. In a room of 12 m² to 16 m² the frame occupies 15 percent or less of the floor and provides the isolation for everything in the room, which is often simpler than isolating individual benches.
  • Optical testing and metrology of large components. Testing a lens, a mirror or an assembly that is itself several hundred millimetres across needs a bench larger than the component with room for the test arm, and the 1200 x 1500 mm outline provides it.
  • A production or inspection cell with a fixed layout. Where a measurement sequence is repeated and the layout will not change, a large frame built once around that sequence is more stable than a set of smaller benches that get rearranged.

Selection Guide

For this size the selection procedure starts with the building and works back toward the optics, because the building is where the project can fail. The steps below are ordered accordingly.

  1. Walk the access route with a tape measure before anything else. Start at the delivery point and finish at the installation position. Record every door opening (clear width with the door open, and clear height), every corridor width, every corner with the free diagonal available, the lift opening, the lift car internal dimensions and its rated load, and whether a stair route exists as a fallback. Compare each opening against the 1200 mm width and each corner against the 1920.9 mm diagonal plus handling clearance.
  2. Decide whether rigging is needed and who will do it. A 1200 x 1500 mm all-steel frame cannot be carried by two people up a stair. If the route has a corner that cannot take the diagonal, the options are a removable window, a crane through a roof opening, or a different frame size. All three are cheaper to arrange before the order than after delivery.
  3. Check the floor for load and for flatness. At rating each corner carries 175 kg (386 lbs), which is 1717 N concentrated into the contact area of one pad. On a suspended slab, confirm the imposed load with the building engineer. On a raised access floor, check the panel rating and the pedestal positions, and plan spreader plates. A floor that deflects under the frame adds a spring in series and degrades the isolation.
  4. Calculate the payload budget rather than the total. Take 700 kg, subtract the mass of the breadboard actually specified, then subtract 20 to 30 percent of the rating as a growth margin. The result, between 490 kg and 560 kg total, is what the equipment has to fit inside. If the layout is close to that figure, the next frame down may be the better choice.
  5. Plan the air supply route. The frame needs continuous clean dry regulated air. Decide where the compressor or the house air take-off will be, how the line reaches the frame without crossing a walkway at head height, where the filter-regulator and gauge will sit, and whether the supply stays pressurised overnight. On a large frame the line is longer and the pressure drop matters more.
  6. Confirm the frame height and the working height. 700 mm (27.5 in) is standard, 800 mm (31.5 in) is available. On a large bench the working height interacts with reach: a 1200 mm deep surface means the far edge is 1200 mm from the near edge, so an operator working at the centre is reaching across 600 mm. Standing height is often preferred on this size for that reason.
  7. Check the centre of gravity and the distribution. A large frame tolerates asymmetry better than a small one because the support base is wider, but a multi-station layout with heavy equipment at one end still creates a moment. Keep the heaviest items near the centre of the four support points and put ballast low.
  8. Decide on casters and on the installation sequence. The PWA061 set is for final positioning within a room. Plan the sequence: frame in first, then breadboard, then equipment, with the air connected and the leveling settled before the optical build starts.

Series Comparison

The PFA range shares one isolator design and one 700 kg rating across six outlines. This model is the largest, and the comparison below is about what the extra area buys and what it costs in site difficulty.

Model Breadboard Size Area (m²) Clear Span Outline Diagonal Practical Constraint
PFA51509 750 x 750 mm 0.5625 650 mm 1092 mm Single setup, any door
PFA51505 750 x 900 mm 0.6750 800 mm 1171 mm Single workstation
PFA51508 750 x 1200 mm 0.9000 1100 mm 1415 mm Long straight path
PFA51507 900 x 1200 mm 1.0800 1100 mm 1500 mm Two stations, centre lane
PFA51502 900 x 1500 mm 1.3500 1400 mm 1749 mm Multi-station
PFA51504 1200 x 1500 mm 1.8000 1400 mm 1921 mm Largest, room-scale base

The diagonal column is the one that changes character across the range. Up to about 1500 mm the frame can generally be walked through a double door or a wide corridor with two people. Beyond that the diagonal starts to exceed the width of ordinary openings, and the move becomes a rigging exercise. This model, at 1921 mm, sits firmly in that second category, and the 900 x 1500 mm frame at 1749 mm is close to the boundary. That is the practical reason the largest outline is a different kind of purchase rather than just a bigger version of the same one.

In optical terms the step from 900 x 1500 mm to 1200 x 1500 mm is a change of width: the clear span along the length is the same 1400 mm, so the fold count on a given path does not change. What the extra 300 mm of width buys is the ability to place several parallel stations across the bench rather than along it, which is what a whole-room installation needs. If the layout is a single long path, the extra width buys nothing and the smaller frame is the better purchase.

FAQ

What is the first thing to check before ordering this frame?

The access route. Measure every door opening, corridor width, corner and lift on the path from the delivery point to the installation position, and compare them against the 1200 mm width and the 1920.9 mm diagonal. A frame that cannot reach the room is a costly problem to discover on delivery day, and a route survey takes an hour.

Can the frame be taken through a standard door?

Not on edge. A standard 800 mm or 900 mm door is narrower than the 1200 mm side of the frame, and carrying it flat needs more than 1200 mm of clear width plus handling clearance. A 1300 mm opening gives 50 mm each side and is workable for a straight run; a 1500 mm opening is comfortable. Anything narrower requires a different route, a removable opening, or a smaller frame.

Why does the diagonal matter more than the width?

Because turning a corner swings the diagonal. The 1200 x 1500 mm outline has a diagonal of 1920.9 mm, and a 90 degree turn requires a clear area at the corner roughly equal to that diagonal plus handling clearance, about 2062 mm. A corridor can be wide enough for the frame to pass in a straight line and still fail at the corner, which is why the free diagonal at the tightest turn is the measurement that matters.

Is 700 kg enough for a bench this large?

It is the same rating as every other size in the range, and it is usually enough, but the arithmetic is different on this outline because the breadboard is a large fraction of the total. A 150 kg breadboard leaves 550 kg of payload, a 250 kg breadboard leaves 450 kg, and a 20 to 30 percent growth margin brings the working figure to between 490 kg and 560 kg total. On a multi-station bench that figure is reachable, so the budget should be calculated rather than assumed.

What floor loading does the frame impose?

At rating, each corner carries 175 kg (386 lbs), or 1717 N, concentrated into the contact area of one leveling pad or foot. If that contact area is 100 x 100 mm the bearing pressure is about 172 kPa; if it is 120 x 120 mm it is about 119 kPa. Take the actual contact area from the current drawing and confirm the imposed load with the building engineer on a suspended slab, or the panel rating on a raised access floor.

Can the frame be assembled in the room rather than moved in assembled?

The frame is supplied as a welded steel structure rather than as a kit, so it arrives assembled. That is deliberate: the rigidity of the frame is what makes the isolation work, and a bolted-together frame on site would not have the same stiffness. Plan the route around an assembled frame, or plan for a rigging contractor.

How much room does the frame need around it?

At least 600 mm of clear aisle on the sides where people work, and more where a trolley or a second operator needs to pass. A 1.8 m² frame in a 12 m² room takes 15 percent of the floor before any aisle is counted, so a large frame in a small room is a layout problem as much as a structural one. Check that the room still works with the frame in it, not just that the frame fits.

Does a larger frame isolate better than a smaller one?

No. The isolators are the same, so the resonant frequencies, the leveling repeatability and the attenuation behaviour are the same at 1.6 Hz vertical and 1.2 Hz horizontal on every size. What a larger frame provides is more surface, a wider support base that tolerates off-centre loads better, and the ability to keep several stations on one inertial reference. It is not better isolation; it is more isolation.

What happens if the air supply fails on a frame this large?

The tabletop settles onto its supports and the frame becomes a rigid steel structure. Nothing is damaged if the descent is gentle, but on a 1.8 m² surface a small tilt produces a large displacement at the far edge, so a pressure loss is an alignment event rather than only a loss of isolation. Fit a gauge where it can be seen, and consider an alarm if the experiment runs unattended.

Can the frame support a breadboard larger than 1200 x 1500 mm?

The frame family as a whole supports breadboards up to 1200 x 1800 mm (48 in x 72 in), but this model is dimensioned for 1200 x 1500 mm. A larger breadboard overhangs the support points, which moves the centre of gravity outward as well as upward, and the overhanging portion is unsupported. Match the breadboard to the frame outline rather than the other way round.

Is the 800 mm height version available for this outline?

Yes, an 800 mm (31.5 in) frame height is available in the same family. The isolation performance is identical; the difference is the working height and, marginally, the height of the centre of gravity above the floor. On a bench this deep, standing height is often preferred because an operator working at the centre is reaching across 600 mm.

Usage Precautions

The precautions for this frame are mostly about installation and site conditions rather than about the optical layout, because that is where a project of this size usually goes wrong. They are listed in the order in which they arise.

  • Survey the route before ordering, and again before delivery. Doors, corridors, corners, lifts and stairs. Record clear dimensions with doors open and obstructions removed, and compare every corner against the 1920.9 mm diagonal plus handling clearance. A route that worked during the site visit can fail on delivery day if a wall cabinet has been fitted in the meantime.
  • Engage rigging support if the route is marginal. A 1200 x 1500 mm all-steel frame is not a two-person lift. If any part of the route is marginal, arrange a rigging contractor, a crane or a removable opening in advance, and confirm the delivery vehicle has a tail lift or that a forklift will be available.
  • Confirm the floor rating and plan spreader plates. Each corner carries 175 kg (386 lbs) at rating, concentrated into one pad. On a raised access floor, check the panel rating and the pedestal layout, and use spreader plates where the point load is marginal. A deflecting floor adds a spring in series and reduces the isolation the frame was bought for.
  • Calculate the payload, do not assume the rating. Subtract the breadboard mass from 700 kg, then take off a 20 to 30 percent growth margin. The remaining figure is the equipment budget. On this outline the subtraction is significant and a heavy tabletop can consume a third of the rating.
  • Route the air line properly. Clean, dry, regulated air, a filter-regulator at the frame inlet, a gauge where the operator can see it, and a line that does not cross a walkway at head height. Take the required pressure and flow from the installation manual for the exact model. Check that the supply stays pressurised overnight, or accept a daily settle and re-level.
  • Install in the right sequence. Frame into position, connect air, level on the pads and feet, bring up pressure and let the valve settle, then fit the breadboard, then let it settle again, then build the optics. Building optics on an unsettled bench is how alignment work gets repeated.
  • Keep the load centred and low. A wide base tolerates asymmetry better than a narrow one, but a multi-station layout with a heavy instrument at one end still creates a moment. Place heavy items near the centre of the four support points, put ballast and power supplies low, and avoid tall risers that lift mass above the table.
  • Respect the diaphragm. The rolling rubber diaphragm is the seal that permits frictionless vertical travel. Solvents, sharp edges and abrasion end its life, and on a large bench there is more surface area for spills to reach. Wipe spills rather than flooding the frame with cleaning fluid.
  • Do not measure on casters, and do not move a loaded frame. The PWA061 set is for final positioning of an unloaded or lightly loaded frame. Moving a 700 kg bench on casters across a floor joint is how frames get damaged and people get hurt.
  • Allow settling time after every change, and record the air pressure. Adding mass anywhere on a 1.8 m² surface moves the whole tabletop. Give the valve time to settle and the breadboard time to stop ringing, and log the supply pressure so that a slow drift is noticed before it becomes an unexplained alignment change.

Disclaimer

The specifications on this page are reproduced from Thorlabs published product information for the PFA series and are provided for selection and planning. Where the current official datasheet, drawing or installation manual differs from this summary, the official document takes precedence, and the manufacturer may revise specifications without notice.

The site-survey tables are derived, not published. Door verdicts, diagonal clearance, payload budgets, bearing pressures and floor-area shares all depend on stated assumptions: a frame carried on edge, 50 to 150 mm of handling clearance, example breadboard masses, and assumed pad contact areas of 100 x 100 mm and 120 x 120 mm. Replace every assumption with a measured value from the site and from the current drawing before using these figures for structural, access or safety decisions. A route survey and a floor check by a qualified person remain necessary regardless of what any table says.

Load capacity, resonant frequencies and leveling repeatability are quoted for the conditions defined by the manufacturer and will vary with the payload installed, its distribution, the floor and the quality of the air supply. No transmission curve is reproduced here; where a project requires a specific isolation performance at a specific frequency, request current performance data for the exact configuration.

No price is stated on this page. Availability, lead time and price are confirmed at the time of enquiry and may change with stock and currency. Nothing on this page constitutes a warranty, and the terms of sale are those agreed at the time of order.

Contact Us

For a quotation on PFA51504, or for help judging whether a proposed installation is feasible, send the room dimensions, the door and corridor clear widths, the free diagonal at the tightest corner, the lift dimensions and rated load, the floor construction, the planned breadboard mass and the estimated equipment mass, and the position of the air supply. Those details decide feasibility before they decide price, and on this outline feasibility is the harder question.

For a project comparing this frame with the 900 x 1500 mm model, say so and include the layout sketch. The two share the same 1400 mm clear span, so the choice turns on whether the layout needs several parallel stations across the width and on whether the access route can take a 1921 mm diagonal, not on optical performance.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PFA51504 Active Isolation Breadboard Support Frame, 700 mm Height, 1200 x 1500 mm”

Your email address will not be published. Required fields are marked *

中文EN