QQ: 859818709

Beam Expander Calculator

Beam Expander Calculator

Laser optics · Online calculation tools

Optical Beam Expander Calculator (Beam Expander)

Based on the two afocal configurations, Keplerian and Galilean, this calculates the focal length ratio, lens separation, output beam diameter and divergence angle of a laser beam expander. It enlarges the beam diameter while compressing the divergence angle by the same factor, providing a quick tool for selecting and aligning expanders for laser processing and long-distance transmission.

M = f2 / |f1|
Dout = M · Din
θout = θin / M
Keplerian: d = f1+f2 (common real focus)
Galilean: d = f2−|f1 (virtual confocal)

Beam Expander Parameter Calculator

Select the configuration type and enter parameters to automatically calculate the focal length ratio, lens separation, output beam and Rayleigh range. Ideal thin-lens, paraxial, afocal model; the divergence angle is entered as a half-angle (angle between a ray and the optical axis), and the beam diameter defaults to the 1/e² criterion.



Input parameters

×

mm

mm

nm

mrad


Calculation results

Output parameters (ideal confocal)
Output lens focal length f2
—mm
Lens separation / total length d
—mm
Output beam diameter Dout
—mm
Output divergence half-angle θout
—mrad
Output Rayleigh range zR
—πw₀²/λ
System total length L (thin lens)
—
Keplerian: L1 and L2 are both positive lenses sharing a real focal point
d = f1 + f2
Both lenses are positive, f1、f2 both taken as positive.

Keplerian:Two positive lenses share an internalreal focal point, the rays genuinely converge and cross between the lenses; total length d = f1+f2, relatively long. A pinhole/aperture can be placed at the focus for spatial filtering; at high power the power density at the focus is high, so beware of air breakdown and dust ablation.

📐 Ray diagrams of the two types of beam expander

Drawn strictly to afocal confocal geometry: in the Keplerian type the rays cross at the real focus between the lenses; in the Galilean type they do not cross and the virtual focus lies to the left of the negative lens (dashed lines are back-extensions). Click to switch.


Ray diagram of a Keplerian laser beam expander: two positive lenses share a real focal point, with the rays crossing between the lenses at the focus

Note: the diagrams show the principle, not to numerical scale; blue biconvex lenses are positive and red biconcave lenses are negative. With ideal confocal alignment the output is collimated light (upper and lower edges horizontal) and output diameter = M × input diameter. The Keplerian type forms an inverted image and the Galilean an upright one, which has no effect on rotationally symmetric laser intensity profiles.

📖 Formula details

Ideal thin-lens, paraxial, afocal (collimated light in → collimated light out) model; d is measured as the separation between the principal planes of the two lenses

① Expansion magnification
M = |f2 / f1|
f1: focal length of input lens L1 (mm, negative for the Galilean type);f2: focal length of output lens L2 (mm, always positive);M: beam diameter magnification (also the factor by which divergence is reduced), M ≥ 1. The longer-focal-length positive lens is at the output end.
② Keplerian lens separation
d = f1 + f2
The adjacent foci of two positive lenses coincide between the lenses as a singlereal focal point, making the system afocal.d: separation between the principal planes of the two lenses (mm), relatively large. Example: f1=25、M=5 → f2=125,d=150 mm。
③ Galilean lens separation
d = f2 − |f1|
Negative lens L1 (f1<0), image-sidevirtual focus coincides with the object-side focus of positive lens L2 on the left of L1 (virtual confocal). Uniformly written as d = f1+f2 (substituting the negative f1). Requires f2>|f1 > |f|. Example: |f1|=25、M=5 → f2=125,d=100 mm。
④ Output beam diameter
Dout = M · Din
Din: input beam diameter (mm);Dout: beam diameter after expansion (mm). By default the Gaussian beam 1/e² intensity criterion is used (the full width where the intensity falls to 1/e²≈13.5% of the on-axis value).
⑤ Output divergence angle
θout = θin / M
θin: input beamhalf-divergence angle (angle between a ray and the optical axis, mrad);θout: output half-divergence angle (mrad). Expanding by a factor M reduces the half-angle to 1/M (likewise the full cone angle), a consequence of the Lagrange invariant (beam conservation), independent of wavelength.
⑥ Output Rayleigh range
zR = π · w0² / λ
w0: output beam waist radius = Dout/2(m);λ: wavelength (m);zR: output beam Rayleigh range (m), indicating the length over which the beam remains approximately collimated; it increases markedly after expansion. Gaussian beam definition under the 1/e² criterion.

🎛️ How to choose parameters

Three key dimensions determine the size and suitability of a beam expander

🔭
Magnification M and focal length ratio

M=f2/|f1| determines the output diameter and total length. Common values are 2×/3×/5×/8×/10×; higher magnification gives a thicker output beam and smaller divergence, but the lens aperture, total length and alignment difficulty all increase. First infer M from the acceptable downstream far-field divergence angle θout=θin/M, then choose f1 and the configuration type according to the available total length.

🌈
Diameter, divergence angle and wavelength

Dout=M·Din depends only on the magnification and input diameter; θout=θin/M is independent of wavelength. The wavelength λ enters only the Rayleigh range zR=πw0²/λ: for the same waist, a shorter wavelength gives larger zR. Note the diameter defaults to the 1/e² criterion; if you measured the FWHM diameter, multiply by 1.699 first to convert.

⚖️
Keplerian vs Galilean

For spatial filtering/pinhole, good beam quality and moderate power → Keplerian; for compactness, high power (marking/cutting/welding) and continuous zoom → Galilean. With the same parameters (f1=25, M=5), the Keplerian is 150 mm long and the Galilean only 100 mm, and the Galilean has no real-focus hot spot between the lenses.

📋 Quick reference table

Geometric parameters for common laser wavelengths and typical expansion magnifications (f1=25 mm, ideal thin lens)

Common laser wavelengths and typical applications
Wavelength Type Typical applications
355 nm Ultraviolet (UV) UV marking, precision wafer/glass cutting, micromachining
532 nm Green Green marking, thin-sheet/transparent material processing, pumping, measurement
632.8 nm He-Ne Collimation, alignment, interferometry, teaching experiments
1064 nm Near-infrared Fibre/Nd:YAG marking, cutting, welding (the most common industrial wavelength)
10.6 μm CO₂ Non-metal cutting and marking, thin-sheet welding, requiring IR-specific optics (ZnSe, etc.)
f for typical magnifications2 and separation (f1=25 mm)
Magnification M f2 (mm) Keplerian d (mm) Galilean d (mm)
2× 50 75 25
3× 75 100 50
5× 125 150 100
8× 200 225 175
10× 250 275 225
20× 500 525 475

Galilean column f1 taken as the absolute value 25 mm; dKeplerian=f1+f2,dGalilean=f2−|f1|。

⚠️ Common misconceptions and cautions

Physical mistakes most easily made when selecting a type and reading ray diagrams

Do the rays in a Galilean expander also cross at a point between the lenses?

No. After the negative lens the rays keepdiverging and never cross between the lenses; the so-called ‘convergence point’ is the virtual focus to the left of the negative lens, which can only be shown by a dashed back-extension. Many diagrams (including some reference pages) draw it as a crossing between the lenses, which is a fundamental error.

Can the rays avoid crossing in the middle of a Keplerian expander?

No. In a Keplerian expander the two positive lenses share an internalreal focal point, and the marginal rays must genuinely converge into an X shape between the lenses before diverging; merely ‘narrowing a little without crossing’ is also wrong. This real focus is exactly where a pinhole can be placed for spatial filtering.

Does expansion only enlarge the diameter while leaving the divergence unchanged?

No. An afocal system obeys beam conservation: as the diameter is enlarged M times,the half-divergence angle is reduced to 1/M(θout=θin/M). This is exactly why expansion is used for long-distance transmission to obtain a finer far-field spot.

Galilean f1 also substituted as a positive value into the separation formula?

That gives a wrong answer. Galilean L1 is a negative lens, so in the general formula d=f1+f2 the f1 must be negative, i.e. d=f2−|f1|. Using a positive value gives 150, but the correct result is 100 (f1=−25、f2=125)。

Can a Keplerian expander be chosen arbitrarily for high-power lasers?

There is a risk. In a Keplerian expander the power density at the internal real focus rises sharply with the square of the convergence ratio, and an intense laser may causeair breakdown, dust ablation and air-turbulence disturbance; high-power processing usually prefers the Galilean type with no internal focus, or uses measures such as a large f/# and vacuum evacuation.

Is a higher magnification always better?

No. The magnification is limited by the clear aperture of the lenses (CA2 must at least capture Dout, with a 20% margin recommended), as well as by diffraction and alignment tolerances; too large a value also inflates the total length and size. Choose the smallest magnification that suffices, based on the target far-field divergence angle and space budget.

θout=θin/M and the Gaussian diffraction angle the same thing?

No. The former is the geometric compression ratio of the input ray angle by the afocal system, independent of wavelength; the latter, θG=λ/(πw0, is the diffraction divergence angle of the output beam itself, determined by the waist and wavelength. An input of 1.0 mrad is usually the beam-envelope half-angle, not the diffraction-limited angle.

Can the 1/e² diameter be used directly as the FWHM?

No, they differ by about a factor of 1.699 (D1/e²=1.699·DFWHM). Mixing them up makes the beam waist, Rayleigh range and divergence all off by about 70%. This calculator defaults to 1/e²; FWHM data must be converted first.

💡 Common application scenarios

⚙️
Laser marking / cutting / welding
Expansion ahead of the processing head fills the galvanometer/f-theta lens aperture and compresses the far-field divergence angle, yielding a finer focused spot and greater depth of focus. High-power applications mostly use the compact Galilean type with no internal hot spot.
🛰️
LiDAR / interferometry / long-range illumination
Expansion reduces the divergence angle by a factor M, decreasing far-distance spot spread and increasing return signal strength and collimation length; interferometry, holography and alignment systems also use expansion to obtain a large, parallel, uniform beam.
🔬
Research and spatial filtering
A pinhole (spatial filter) can be placed at the internal real focus of a Keplerian expander to remove high-frequency stray light and improve beam quality; it is widely used in research and precision measurement systems that demand high beam cleanliness.

❓ Frequently asked questions

Q: How do I choose between Keplerian and Galilean beam expanders?
Choose the Keplerian type if you need a pinhole/aperture at the focus for spatial filtering, want good beam quality and have moderate power; choose the Galilean type if you want compactness, high-power laser marking/cutting/welding or continuous zoom. At the same magnification the Galilean type is shorter and has no real focus between the lenses, avoiding air breakdown.
Q: Why does the divergence angle decrease after expansion?
A beam expander is an afocal telescope satisfying the Lagrange invariant: when the beam diameter is enlarged M times, the half-divergence angle shrinks by the same factor, θout=θin/M. Expansion therefore extends the collimation distance and narrows the far-field spot.
Q: How is the total length of a beam expander calculated?
With afocal confocal alignment, the separation between the principal planes is the thin-lens total length: Keplerian d=f1+f2, Galilean d=f2−|f1|. For example, f1=25 mm and M=5 gives f2=125 mm, with the Keplerian at 150 mm and the Galilean at 100 mm. The actual mechanical length must also allow for lens thickness and alignment margins.
Q: Can a beam expander be used in reverse as a beam reducer?
Yes. Sending the beam in reverse from the large-aperture end L2 turns it into a beam reducer: the beam diameter becomes 1/M of the original and the half-divergence angle increases M-fold. The Keplerian type inverts the image and the Galilean keeps it upright, but neither affects a rotationally symmetric laser intensity profile.

Disclaimer: this tool is based on an ideal thin-lens, paraxial, single-wavelength afocal model, with separations calculated between the lens principal planes and without thick-lens/multi-element principal-plane shifts, aberrations or material and coating losses; the results are for selection and estimation reference, and precise design should follow actual optical designs and datasheets.

中文EN