Description
Product Overview
This is the 10-piece pack of the PF05-03-M02; the optic is identical to the single-unit version. Ten Ø12.7 mm mid-infrared enhanced gold mirrors on 6.0 mm fused silica, each with average reflectance above 98% and absolute reflectance above 95% from 2 µm to 20 µm at 0° to 45° angle of incidence, better than λ/10 at 633 nm, 40-20 scratch-dig, a Ø11.4 mm clear aperture and the part number engraved on the back.
An instrument builder buys this pack rather than ten singles for reasons that have nothing to do with the coating. A gas analyser with a Herriott cell and a beam-steering section may carry six to ten plano mirrors of this size; a mid-infrared spectrometer may carry four in the sample compartment alone. Ordered as singles, those become ten line items, ten deliveries and ten separate receiving inspections, and the assembly cannot be signed off until the last one lands. One part number and one delivery collapses that.
The other reason is service. Mid-infrared instruments are usually installed, aligned once and then maintained for years, and the mirror that fails is almost always the one nearest a cell window or a sample port, where contamination reaches the surface. A pack on the shelf turns that repair into a same-week job instead of a purchase cycle. It also means the replacement is the same part number, with the same coating and the same 98% figure, so the instrument does not have to be recalibrated against a mirror with different throughput.
Two cautions belong on a page like this. First, do not mix coatings inside one instrument: a -M01 and a -M02 look alike, fit the same mount and behave differently in the near infrared, and a mixed set is the classic cause of a throughput figure that cannot be reproduced. Second, the pack does not change the physics: every piece is rated 0.1 J/cm² at 1.064 µm and 25 W/cm CW at 1.070 µm, so a 1064 nm alignment laser left running through the cell is still outside the design band. Ten identical mirrors means ten identical mistakes if the coating is wrong, so check the band before the quantity.
For a first sample, the single-unit PF05-03-M02 is the same optic in a quantity of one and is the lower-commitment way to prove a design before committing to a pack.
Key Features
- Ten mirrors, one part number: the PF05-03-M02 optic, supplied as a pack for instrument builds that consume several mirrors
- One delivery for one build: a six-mirror steering section or a four-mirror spectrometer is completed in one session
- Uniform optics: over 98% average and over 95% absolute reflectance from 2 µm to 20 µm on every piece
- MIL-C-48497A overcoat on all ten, so service replacements carry the same durability as the originals
- Engraved part number on the back of each mirror, which keeps a mixed bench honest
- Identical envelope to the single unit: 12.7 mm diameter, 6.0 mm ± 0.2 mm thick, Ø11.4 mm clear aperture
- Service stock: the mirror nearest a cell window is the one that fails, and the pack covers the repair without a purchase cycle
Technical Specifications
| Parameter | Value |
|---|---|
| Model | PF05-03-M02-10 |
| Pack size | 10 pieces |
| Optic | Identical to PF05-03-M02 |
| Coating | Mid-infrared enhanced gold, dielectric overcoat |
| Wavelength range | 2 µm – 20 µm |
| Reflectance | R_avg above 98%, R_abs above 95% from 2 µm to 20 µm |
| Angle of incidence | 0° to 45° |
| Substrate | Fused silica |
| Diameter | 12.7 mm (Ø1/2 inch) |
| Diameter tolerance | +0.0 mm / -0.1 mm |
| Thickness | 6.0 mm (0.24 inch) |
| Thickness tolerance | ±0.2 mm |
| Clear aperture | Ø11.4 mm |
| Front surface flatness | better than λ/10 peak to valley at 633 nm |
| Surface quality | 40-20 scratch-dig |
| Parallelism | inside 3 arcmin |
| Overcoat specification | MIL-C-48497A |
| Damage threshold, pulsed | 0.1 J/cm² at 1.064 µm, 10 ns, 10 Hz, Ø1.06 mm; 3 J/cm² at 10.6 µm, 100 ns, 1 Hz, Ø1.29 mm |
| Damage threshold, CW | 25 W/cm at 1.070 µm, Ø1.04 mm; 450 W/cm at 10.6 µm, Ø1.18 mm |
| Marking | Part number laser engraved on the back of each mirror |
| Source | Thorlabs official series specification table |
Applications
Where a pack of mid-infrared plano mirrors is the natural purchasing unit:
- Gas analyser production: a Herriott cell plus a steering section per instrument, several instruments per quarter, all needing the same plano mirror
- Spectrometer manufacturing: four folds inside a sample compartment, replaced as a set when the instrument is serviced
- OEM pilot runs: ten pieces covers a pre-production batch of two or three instruments before a volume order is agreed
- Field service kits: a service engineer carrying one pack can restore any of the instruments in a fleet without a part-number question
- Laboratory rebuilds: an older FTIR or thermal imager brought back into service with matched optics throughout the relay
Selection Guide
Quantity is the first decision, coating the second. The table gives the pack options in the half-inch size so the two can be settled together.
| Pack | Coating | Band | Average reflectance | Typical use |
|---|---|---|---|---|
| PF05-03-M01-10 | Protected gold | 800 nm – 20 µm | over 96% | Mixed near and thermal infrared paths |
| PF05-03-M02-10 (this page) | MIR enhanced gold | 2 µm – 20 µm | over 98% | Mid-infrared instruments only |
| PF05-03-G01-10 | Protected aluminum | 450 nm – 20 µm | over 90% to 2 µm, over 95% beyond | Visible and near-infrared work |
If the instrument works entirely beyond 2 µm, this pack is the right unit. If any wavelength below 2 µm has to pass through the same mirrors, switch the whole build to the PF05-03-M01-10 protected gold pack rather than mixing the two, and if the mirrors are behind a sealed window where nothing will ever touch them, the unprotected gold single is one point higher in reflectance. For a visible or near-infrared instrument the protected aluminum pack is the equivalent.
FAQ
Is every mirror in this pack optically identical to the single-unit PF05-03-M02? Yes: same coating, same overcoat specification, same substrate, same figure and finish, same damage ratings. The pack differs in quantity and in the part number printed on the label.
Can I split a pack between two instruments with different requirements? You can, but do not split it between coatings. All ten pieces here are -M02 and are specified from 2 µm upward; if one instrument also uses a 1.5 µm source, it needs the -M01 coating on its own mirrors.
How many mirrors does a typical Herriott cell instrument need? The cell itself uses two concave mirrors, which are a separate part, plus two or more plano mirrors to inject and extract the beam. Tell us the layout and we will list the plano count for one instrument and for a production batch.
Are the ten mirrors from one coating run? Thorlabs does not publish that guarantee for a stocked multipack and we will not claim it. What the pack does guarantee is one part number, one specification and one delivery.
Is there a smaller quantity for a prototype? Yes, the single-unit PF05-03-M02. Ordering one first and a pack afterwards is the normal route for a new instrument design.
Disclaimer
The figures listed above reproduce the Thorlabs specification for the PF05-03-M02 family and are given to support a purchasing decision between quantities. The official datasheet current at the time of order takes precedence, and specifications or marking may be revised without notice. Quantity quotations, stock position and lead time are confirmed by our sales team at the time of quotation.
Contact Us
Changsha Soar Laser Equipment Co., Ltd. supplies genuine Thorlabs optics to instrument manufacturers and research laboratories in China. For a bill of materials covering both plano and concave mid-infrared mirrors, send the layout or the part list and we will check quantities against one instrument and against the planned production batch. Hotline +86 159 2722 0467, email 859818709@qq.com, website www.soar-laser.cn. If the pack is meant as field service stock, tell us the fleet size and we will advise how many packs keep a service visit self-contained.