Galvo welding has been adopted more and more in recent years — new-energy power batteries, precision welding of 3C electronics, automotive parts manufacturing, and medical-device welding (clean, free of thermal damage, high precision) all rely on it. Yet many people get confused when choosing an F-Theta lens: how to pick the focal length, and how to weld finely? How do I choose so the weld penetration is deeper? And how do I strike the right balance between fineness and penetration? Today let’s talk practicalities.
First, understand the premise
A galvo welding system is not the same as a marking system. Marking machines use Q-switched or MOPA laser sources, which output a parallel beam that goes straight into the galvo scanner. A galvo welding system, however, uses a continuous-wave fiber laser; the laser exits through a QBH/IQB connector as a divergent beam, and it must first be compressed into a parallel beam by a collimator before entering the galvo system.
So the optical path of a galvo welding system is:
laser source → QBH/IQB → collimator → galvo scanner → F-Theta lens → workpiece
Before choosing an F-Theta lens, confirm these 4 parameters
This calculation requires you to first look up the parameters of your own laser:
- The laser’s NA value — for continuous fiber lasers it is usually 0.11, with some at 0.22; see the laser’s spec sheet or consult the laser manufacturer.
- The laser’s fiber core diameter — commonly 25μm, 50μm, or 100μm; check the laser’s spec sheet
- The collimator’s focal length — commonly 75mm, 100mm, or 150mm; check the spec of the collimator you bought
- The F-Theta lens’s focal length — common models are F160, F210, F254, F380, F420; choose according to your processing needs
All 4 numbers are indispensable; if you don’t know them, check the laser manual or ask the manufacturer.
First: how to calculate the collimated beam diameter
D = 2 × f_c × NA
D = collimated beam diameter
f_c = collimator focal length
NA = fiber numerical aperture
Second: how to calculate the focused spot diameter
d = (d_fiber × f_f) / f_c
d = focused spot diameter
d_fiber = fiber core diameter
f_f = F-Theta lens focal length
f_c = collimator focal length
Selection order matters more than the formulas
When choosing optics for a galvo welding system, there is a strict hierarchy:
F-Theta entrance pupil ≥ galvo aperture ≥ collimated beam diameter D
In plain language:
- Calculate D first
- If D exceeds 20mm, the galvo aperture must be 30mm or larger (because it must be ≥D)
- Then the F-Theta lens’s entrance pupil must also be ≥ the galvo aperture
- Only then choose the focal length and calculate the spot
How it works in practice
Suppose you have these parameters on hand:
- NA = 0.11
- Fiber core diameter = 50μm
- Collimator focal length = 100mm
- You want an F160 F-Theta lens
Step 1: collimated beam diameter
D = 2×100×0.11 = 22mm
Step 2: the galvo aperture must be ≥22mm, typically 30mm
Step 3: the F-Theta entrance pupil must be ≥30mm
Step 4: focused spot
d = (0.05×160)/100 = 0.08mm = 80μm
If you choose an F210 F-Theta lens:
d = (0.05×210)/100 = 0.105mm = 105μm
How to balance focal length, spot size, and depth of focus
The longer the focal length, the larger the spot and the more dispersed the energy density, but the longer the depth of focus as well. With sufficient laser power you can melt deeper — thick-plate welding needs a long depth of focus.
The shorter the focal length, the smaller the spot and the more concentrated the energy density. But the working distance is short and spatter increases. The shallow depth of focus suits thin-plate welding only; for thick plates the insufficient depth of focus means the weld will not penetrate fully, even if the laser power is enough.
So when choosing focal length, do not fixate on spot size alone — you also need to consider how thick the plates you weld will be.
Summary
To choose an F-Theta lens for a galvo welding system, the key is to confirm 4 parameters first: NA value, fiber core diameter, collimator focal length, and F-Theta focal length. Then follow the order: calculate the collimated beam diameter D, determine the galvo aperture size, select the F-Theta entrance pupil, and finally choose the focal length according to your focused-spot requirements. Get the order backwards and you will at best waste money and at worst end up with something that simply cannot be used. If you are really unsure, send your laser parameters to an optics parts supplier and have them configure a matched set for you.