MTF Cut-off Frequency Calculator

MTF Cut-off Frequency Calculator

📊 MTF Cutoff Frequency Calculator

MTF Cutoff Frequency Calculator

Calculate the modulation transfer function (MTF) cutoff frequency and Airy disc diameter at the diffraction limit of an optical system, and evaluate the maximum resolvable spatial frequency of the system.

📊
Cutoff frequency
fc = 1 / (λ · F/#)
Line pairs/mm (lp/mm)
Airy disc diameter
d = 2.44 · λ · F/#
Rayleigh criterion, diameter of the first dark ring
Rayleigh resolution
r = 1.22 · λ · F/#
Minimum resolvable separation between two points

📊 MTF Cutoff Frequency Calculator

Enter the wavelength and f-number to automatically calculate the diffraction-limited cutoff frequency, Airy disc diameter and Rayleigh resolution


nm

550 nm (green) is commonly used for visible light; Nd:YAG is 1064 nm

Aperture value, e.g. f/1.4, f/2.8, f/5.6


μm

When filled in, the Nyquist frequency and matching status can be calculated


📊 Calculation results
📊 MTF cutoff frequency fc
—
lp/mm
⭕ Airy disc diameter
—
μm
🔍 Rayleigh resolution r
—
μm

Formula details

Resolution performance metrics of an optical system at the diffraction limit

① MTF cutoff frequency
fc = 1 / (λ · F/#)
λ: wavelength (mm),F/#: f-number. fcdenotes the spatial frequency at which the MTF falls to zero; beyond this frequency the system cannot transmit any modulation information.
② Airy disc diameter
d = 2.44 · λ · F/#
The diffraction pattern of a circular pupil is the Airy disc, and the diameter of the first dark ring is this value. This is the smallest spot diameter to which a point source can be focused by an ideal lens.
③ Rayleigh resolution (two-point resolution limit)
r = 1.22 · λ · F/#
The minimum resolvable distance between two points, equal to the radius of the Airy disc. Two point sources can be resolved when their separation is greater than r. Note: r = d/2.
④ Nyquist frequency (sensor limitation)
fnyq = 1 / (2 · p)
p: sensor pixel size (mm). The sampling theorem requires the signal bandwidth not to exceed the Nyquist frequency; otherwise aliasing (moiré) occurs.
⑤ Diffraction limit and pixel matching
fc / fnyq = 2p / (λ · F/#)
Ratio > 2 → the sensor under-samples (the diffraction spot is much smaller than the pixel, resulting in under-sampling); ratio ≈ 1 → good matching; ratio < 0.5 → the sensor limits the resolution.
⑥ MTF curve characteristics
The diffraction-limited MTF curve falls to zero at fcwhere it falls to zero. The curve shape: close to 1 in the low-frequency region (high contrast), falling slowly in the mid-frequency region and dropping sharply to zero near the cutoff frequency. In real systems, owing to aberration, defocus and other factors, the MTF, already at frequencies below fchas dropped substantially.

Parameter details

Key parameters affecting the diffraction-limited resolution

📏

Wavelength λ

  • The shorter the wavelength, the higher the cutoff frequency and the better the resolution
  • Centre of the visible spectrum: 550 nm (green)
  • CO₂ laser: 10.6 μm (far infrared)
  • UV lithography: 193 nm / 248 nm
  • At the same F/#, blue light gives about 30% higher resolution than red light
🔭

F-number F/#

  • The smaller the f-number, the higher the cutoff frequency and the smaller the diffraction spot
  • F/2 → fc ≈ 909 lp/mm (green)
  • F/8 → fc ≈ 227 lp/mm (green)
  • F/22 → fc ≈ 82 lp/mm (green)
  • In real optical systems, aberration makes the effective resolution far lower than fc
📷

Pixel size p

  • The smaller the pixel, the higher the Nyquist frequency
  • 5 μm pixels → f_nyq = 100 lp/mm
  • 2 μm pixels → f_nyq = 250 lp/mm
  • Pixel size determines whether the sensor can fully exploit the optical resolution
  • Pixels too small but f-number too large → wasted sensor

📋 Cutoff frequencies at common laser wavelengths

MTF cutoff frequencies (lp/mm) for different f-numbers

Wavelength F/1.4 F/2.8 F/4 F/5.6 F/8 F/11
355 nm(UV) 2020 1010 705 504 353 256
532 nm (green) 1339 670 468 335 235 170
550 nm (centre of the visible spectrum) 1298 649 455 325 227 165
1064 nm(Nd:YAG) 673 337 236 168 118 85
10600 nm(CO₂) 67 34 24 17 12 8.5

Unit: lp/mm (line pairs/mm)

⚠️ Common pitfalls and notes

The most common mistakes when using the MTF cutoff frequency

Is the cutoff frequency the same as the actual resolution?

The cutoff frequency is the theoretical upper limit at the diffraction limit. In practice the MTF falls substantially before the cutoff frequency is reached because of aberration, defocus and jitter. The usable resolution is typically only 30%~60% of fc.

Is a smaller f-number always better for resolution?

This is true at the diffraction limit, but real lenses suffer severe aberration at small f-numbers, so the resolution wide open may actually be worse than when stopped down by one f-stop. The optimum aperture is usually 2~3 stops down from wide open.

More pixels always mean a sharper image?

Not necessarily. Pixels that are too small lead to diffraction limitation: when the Airy disc covers several pixels, adding more pixels cannot improve resolution. The optical cutoff frequency needs to be ≥ the Nyquist frequency.

Does wavelength only affect colour and not resolution?

Wavelength directly affects the diffraction limit. Blue light (450 nm) produces a diffraction spot about 30% smaller than red light (650 nm), which is why UV lithography can achieve smaller feature sizes.

Are the Airy disc and the Rayleigh resolution the same size?

No. Airy disc diameter = 2.44·λ·F/#, while Rayleigh resolution (minimum resolvable separation of two points) = 1.22·λ·F/# = the Airy disc radius; note the factor of 2.

Can the diffraction limit be ignored in all scenarios?

Diffraction effects are significant at large f-numbers and long wavelengths. A CO₂ laser (10.6 μm) at F/8 has an Airy disc diameter of 209 μm, which limits the processing accuracy. UV processing (355 nm) has a diffraction spot of only 6.7 μm.

💡 Common applications

🔬
Machine vision system matching
When selecting components, ensure the lens MTF cutoff frequency is higher than the sensor Nyquist frequency to avoid wasted optics or under-sampling. Typical target: fc / f_nyq ≥ 1.5.
🔴
Laser processing accuracy assessment
Calculate the diffraction-limited focused spot to assess the minimum processing feature. A UV laser (355 nm) has a focused spot far smaller than a CO₂ laser (10.6 μm), making it suitable for precision processing.
📷
Camera lens aperture selection
When the Nyquist frequency approaches the diffraction cutoff frequency, stopping down further only reduces resolution through diffraction. The optimum aperture requires balancing aberration and diffraction.

📋 Frequently asked questions

Q: Why is the MTF zero at the cutoff frequency?
The cutoff frequency corresponds to the frequency at which the autocorrelation of the pupil function is zero, meaning the system cannot transmit contrast information at that frequency at all. Beyond this frequency, spatial frequencies are completely filtered out.
Q: What is the difference between the Airy disc diameter and the beam waist?
The Airy disc is the diffraction pattern of a plane wave after passing through a circular aperture; the Gaussian beam waist is a beam parameter of the TEM₀₀ mode. The two are different but approximately related at large f-numbers: d_Airy ≈ 2w₀. The actual focused laser spot lies somewhere between the two.
Q: How can you tell whether a lens and sensor are matched?
Compare the diffraction cutoff frequency f_c and the sensor Nyquist frequency f_nyq. f_c/f_nyq ≈ 1~2 indicates good matching; >2 indicates under-sampling (an anti-aliasing filter may be added); <0.5 indicates diffraction limitation.
Q: Why are lenses with small f-numbers more expensive?
A small f-number means a large entrance pupil and a short focal-length ratio, requiring more lens elements to correct aberrations (spherical aberration, coma, field curvature), which greatly increases the difficulty of optical design and manufacture.