QQ: 859818709

Thorlabs PF05-03-P01-10 Ø1/2″ Protected Silver Mirror, 10 Pack, 450 nm – 20 µm

Thorlabs PF05-03-P01-10 Ø1/2″ Protected Silver Mirror, 10 Pack, 450 nm – 20 µm

Price on request
Category:

Description

Product Overview

This is the 10-piece pack of the PF05-03-P01; the optic is identical to the single-unit version. Ten Ø12.7 mm protected silver mirrors, one part number, one shipment. The coating is the same 97% average from 450 nm to 2 µm and 95% from 2 µm to 20 µm, on the same 6.0 mm fused silica disc, figured to λ/10 at 633 nm and polished to 40-20 scratch-dig. What the pack changes is how a multi-station system gets provisioned, and that is the subject of this page.

The arithmetic of a multi-channel build is unforgiving. An eight-channel fiber laser module needs a fold per channel. A twelve-position turret needs twelve identical turns. A four-head gantry needs a fold train at each head plus a combining mirror upstream. In every one of those cases the mirror count is a property of the architecture, not of the budget, and ordering singles means eight or twelve separate line items, eight or twelve receipts, and a real chance that the last two arrive after the assembly fixture is already booked.

Batch consistency is the second reason, and it is a specification rather than a convenience. Thorlabs notes that reflectance outside the guaranteed bands is typical and varies from lot to lot. Ten mirrors from one carton are far more likely to share a coating run than ten mirrors ordered across three months, and in a multi-channel instrument that matters: a channel-to-channel reflectance difference becomes a channel-to-channel calibration difference, and somebody has to chase it. One carton does not guarantee a single lot, but it is the closest a buyer can get without a custom order.

The third reason is administrative. Every mirror in the pack is laser engraved on the back with its item number, so each of the ten can be entered in an asset register, assigned to a station, and traced after a failure without depending on a handwritten label. For a laboratory working to an audit trail, or an OEM that has to answer a field return, that engraving is the difference between “a mirror failed” and “mirror number seven at station four failed”.

What does not change is the cleaning regime, and this is where the protected coating earns its place at pack scale. These ten mirrors can be cleaned with standard optics procedure. A contaminated mirror is recovered rather than scrapped, which is not true of an unprotected metal film and is exactly the property that makes a carton of ten a reasonable holding. The pack is a stock decision, not a licence to relax handling.

One caution about the numbers. Thorlabs publishes a damage threshold of 3 J/cm² at 1064 nm for the protected silver multipack, while the single-unit protected silver series table quotes 1 J/cm² at the same wavelength over a nominally identical spot. The difference is a documentation artefact, not a better coating. We quote the conservative single-unit figure in the table below, and we would not size a beam against the higher number.

Key Features

  • Ten protected silver mirrors, one purchase order: the optic is identical to the single-unit PF05-03-P01, so no separate qualification is needed
  • 97% average reflectance from 450 nm to 2 µm and 95% from 2 µm to 20 µm, the highest visible and near infrared figure among the metal coatings
  • Provision a whole system in one shipment: eight-channel modules, multi-position turrets and multi-head gantries consume this quantity by design
  • Closer lot grouping than ten singles ordered separately, which reduces channel-to-channel calibration spread in multi-channel instruments
  • Item number engraved on every back face, so each of the ten is individually traceable in an asset register
  • SiO₂ overcoat means the ten are cleanable, so a contaminated mirror is recovered instead of scrapped
  • λ/10 at 633 nm, 40-20 scratch-dig, parallelism inside 3 arcmin, clear aperture 90% of the diameter, on a 6.0 mm fused silica disc
  • Conservative damage rating quoted: we use the single-unit 1 J/cm² at 1064 nm rather than the higher pack-table figure

Technical Specifications

Parameter Value
Model PF05-03-P01-10
Coating Protected silver with SiO₂ overcoat, approximately 100 nm
Wavelength range 450 nm – 20 µm
Average reflectance 97% for 450 nm – 2 µm; 95% for 2 µm – 20 µm
Substrate Fused silica
Diameter 12.7 mm (Ø1/2 inch)
Diameter tolerance +0.0 mm / -0.1 mm
Thickness 6.0 mm (0.24 inch)
Thickness tolerance ±0.2 mm
Front surface flatness λ/10 peak to valley at 633 nm
Surface quality 40-20 scratch-dig
Parallelism 3 arcmin or less
Clear aperture 90% of the diameter
Damage threshold, pulsed 0.225 J/cm² at 800 nm, 99 fs, 1 kHz, Ø0.167 mm; 1 J/cm² at 1064 nm, 10 ns, 10 Hz, Ø1.010 mm
Damage threshold, CW 500 W/cm at 1.07 µm, Ø0.974 mm; 1500 W/cm at 10.6 µm, Ø0.339 mm
Pack size 10 mirrors per carton
Marking Item number laser engraved on the back face
Cleaning Standard optics procedure; the SiO₂ overcoat permits wiping
Source Thorlabs official series specification table

Applications

A carton of ten is bought by projects whose mirror count is a design constant. These are the architectures where that is true.

  • Multi-channel fiber laser modules: eight or sixteen amplified channels, each with its own fold onto a combining element, all needing the same reflectance or the calibration drifts
  • Multi-position filter or sample turrets: twelve identical turning mirrors on a rotating carousel, where a single out-of-spec mirror shows up as one bad position
  • Multi-head gantry systems: three or four marking heads sharing a frame, each with a periscope and a focus-head fold, consuming a carton before the second machine ships
  • OEM pilot and first-article builds: five to ten units is precisely the quantity a ten-pack covers, and it keeps the pilot off the production purchasing queue
  • Laboratory stock for shared optical benches: a drawer of matched half-inch silver mirrors ends the practice of borrowing one from an operating experiment
  • Retrofit and upgrade kits: replacing aluminum folds with silver in an existing instrument, where the installed base count sets the order quantity

Selection Guide

A ten-pack is the wrong purchase in three specific situations, and they are easier to recognise than the right one.

  • You need three. The unit price advantage does not survive seven mirrors sitting in a drawer past their calibration relevance, and capital tied up in stock is still capital
  • You need mixed coatings. A pack is fixed contents. A system that wants silver on the visible arm and gold on the infrared arm needs two part numbers, and singles combined on one quotation are cleaner than an unused half carton
  • The bay is humid. Silver is the wrong coating there regardless of quantity, so buy the protected aluminum pack instead of ten mirrors that will tarnish together

If none of those applies, the pack is straightforward. For a single fold the single-unit PF05-03-P01 is the right order, and the coating analysis behind it is on that page rather than this one. Where the count is high but the optics will be handled roughly, the protected aluminum PF05-03-G01-10 trades visible reflectance for a film that survives a harder life.

Series Comparison

Protected silver is offered as a ten-pack in three apertures. The thickness step between them is larger than the diameter step, which is the detail that decides whether an existing mount can take the upgrade.

Pack item number Diameter Thickness Average reflectance Mount consideration
PF05-03-P01-10 12.7 mm (0.5 inch) 6.0 mm 97% / 95% Half-inch kinematic mounts, the default laboratory size
PF10-03-P01-10 25.4 mm (1.0 inch) 6.0 mm 97% / 95% Same 6.0 mm thickness as the half-inch, so depth is not the constraint
PF20-03-P01-10 50.8 mm (2.0 inch) 12.0 mm 97% / 95% Twice the thickness, so check mount depth and ring clearance before ordering

The one-inch pack is the one that surprises people: it is the same 6.0 mm thick as this half-inch part, so an experiment that steps up an aperture class does not need a new mount family. The two-inch pack doubles the thickness to 12.0 mm, which does. Above two inches protected silver is sold as singles only, so a large-aperture multi-station build has to be quoted line by line.

FAQ

Are the ten mirrors identical to the single PF05-03-P01? Yes. Same substrate, same protected silver film, same figure and polish, same laser rating. The difference is packaging, quantity and price per piece.

Do all ten come from one coating run? Not guaranteed. A carton is far more likely to be lot-grouped than ten singles bought over several months, which is the practical benefit, but Thorlabs does not promise a single lot inside a pack. If channel matching is critical, ask us and we will check what we can confirm at the time of order.

Can I order a pack with a mix of coatings? No, packs have fixed contents. Mixed requirements are met by ordering the single part numbers and having them combined on one commercial quotation.

Why does your table show 1 J/cm² when the pack listing shows 3 J/cm²? Because the two Thorlabs tables disagree for a nominally identical coating and spot size. We quote the lower, single-unit figure, and we would not design a beam against the higher one. Treat the difference as a documentation gap rather than a coating improvement.

How are the ten packed? As a single carton of individually protected optics, not a tray of loose discs. Keep the carton closed between uses, keep it dry, and do not transfer mirrors into an unlabelled container, because the engraving is the only identifier left once the packaging is gone.

Can these be cleaned the way our other optics are cleaned? Yes, standard solvent and lens tissue procedure applies, because the SiO₂ overcoat is there to permit it. That is the operational advantage of a protected coating at pack scale: a dirty mirror is recovered, not written off.

Usage Precautions

  • Open the carton in a clean area and take out only the mirrors the current build needs; the rest stay sealed and dry
  • Handle by the edge with gloves, and never let a mirror rest face down on a bench
  • Clean with standard optics procedure only; do not dry-wipe a dusty surface, lift the dust with solvent and tissue instead
  • Record the engraved item number of each mirror against its station at installation, before the mount hides the back face
  • Keep the pack out of humid storage and away from sulfur-bearing atmospheres, which tarnish silver through the overcoat over time
  • Seat with light retaining-ring pressure; a 6.0 mm disc distorts visibly under a ring tightened by feel

Disclaimer

Specifications are transcribed from the Thorlabs protected silver mirror series table and the Thorlabs optics multipack table for selection purposes. Where the two tables differ, this page quotes the more conservative single-unit figure and says so. The official datasheet in force at the time of purchase governs, and the manufacturer may revise figures, pack contents or marking without notice. Lot grouping inside a pack is not guaranteed by the manufacturer. Price, pack availability and lead time are quoted by our sales team against live stock.

Contact Us

Changsha Soar Laser Equipment Co., Ltd. supplies genuine Thorlabs optics to laboratories and machine builders in China, and holds pack quantities for projects that need them in one shipment. If a build has a fixed mirror count, tell us the count and the shortest wavelength in the beam; if the number is close to ten we will say whether the pack or a combined single order is the better commercial route. Hotline +86 159 2722 0467, email 859818709@qq.com, website www.soar-laser.cn.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PF05-03-P01-10 Ø1/2″ Protected Silver Mirror, 10 Pack, 450 nm – 20 µm”

Your email address will not be published. Required fields are marked *

中文EN