QQ: 859818709

Thorlabs PF05-03-F01 Ø1/2″ UV-Enhanced Aluminum Mirror, 250-450 nm

Thorlabs PF05-03-F01 Ø1/2″ UV-Enhanced Aluminum Mirror, 250-450 nm

Price on request
Category:

Description

Product Overview

The Thorlabs PF05-03-F01 is a Ø12.7 mm (Ø1/2 inch) plano mirror with a UV-enhanced aluminum coating on a 6.0 mm fused silica substrate. Average reflectance is above 90% from 250 to 450 nm, the face is figured to λ/10 peak to valley at 633 nm and polished to 40-20 scratch-dig, and parallelism is held within 3 arcmin.

This is the same coating as the Ø7.0 mm PF03-03-F01 that is already in our catalogue, on a larger substrate. Nothing about the film changes with diameter: the reflectance band, the damage thresholds and the handling rules are identical, and only the clear aperture and the mount class differ. The choice between the two is therefore mechanical rather than optical. A compact path, or a mount that is already sized for a 7 mm optic, takes the smaller part; a path that needs a wider clear aperture, or a standard half-inch holder, takes this one, which offers roughly twice the clear aperture for a mount of the next size up.

The reason a UV mirror needs a special coating at all is the native oxide on aluminum. Aluminum reflects well from the visible into the infrared, but in air its surface grows an oxide that absorbs in the ultraviolet, and that absorption is what a plain aluminum mirror loses below 450 nm. The UV-enhanced process deposits the aluminum so that the oxide stays thin and adds a dielectric overcoat, which recovers reflectance across 250 to 450 nm. A dielectric stack could reach higher reflectance over a narrow band, but it would shift with angle and would cover one wavelength range only; a metal film holds across the band and across incidence, which is why it is the practical choice for a path that carries more than one line.

The film is the constraint on use. The aluminum layer is soft and the overcoat is thin, so this is not a cleanable optic: dust is removed with clean dry gas and a tissue wipe that would be routine on a protected gold mirror will leave a scratch. For power, the published pulsed ratings are 0.25 J/cm² at 266 nm and 0.3 J/cm² at 355 nm, both with 10 ns pulses at 10 Hz, and the continuous ratings are 300 W/cm at 1.064 µm and 500 W/cm at 10.6 µm.

Key Features

  • UV-enhanced aluminum, 250 nm – 450 nm: average reflectance above 90% in the band where a plain aluminum film is limited by its native oxide
  • Identical coating to the Ø7.0 mm PF03-03-F01: same film, same thresholds, same handling, so a design can change aperture without requalifying the coating
  • Ø12.7 mm x 6.0 mm fused silica: λ/10 figure at 633 nm, 40-20 scratch-dig, parallelism within 3 arcmin, clear aperture 90% of the diameter
  • Standard half-inch envelope: fits the half-inch mounts and lens-tube threads already on most optical tables
  • Published UV thresholds: 0.25 J/cm² at 266 nm and 0.3 J/cm² at 355 nm with 10 ns pulses, plus 300 W/cm and 500 W/cm continuous ratings
  • Not cleanable: the aluminum is soft and the overcoat thin, so contamination is blown off rather than wiped off

Technical Specifications

Parameter Value
Model PF05-03-F01
Coating UV-enhanced aluminum
Wavelength range 250 nm – 450 nm
Average reflectance Above 90% from 250 to 450 nm
Substrate Fused silica
Diameter 12.7 mm (Ø1/2 inch)
Diameter tolerance +0.0 mm / -0.1 mm
Thickness 6.0 mm (0.24 inch)
Thickness tolerance ±0.2 mm
Surface flatness λ/10 peak to valley at 633 nm
Surface quality 40-20 scratch-dig
Parallelism Within 3 arcmin
Clear aperture 90% of the diameter
Pulsed damage threshold 0.25 J/cm² (266 nm, 10 ns, 10 Hz, Ø0.150 mm); 0.3 J/cm² (355 nm, 10 ns, 10 Hz, Ø0.381 mm)
CW damage threshold 300 W/cm (1.064 µm, Ø0.044 mm); 500 W/cm (10.6 µm, Ø0.339 mm)
Source Thorlabs official product page

Applications

  • Third and fourth harmonic steering: 355 nm and 266 nm beams are folded with a metal film whose thresholds are published at exactly those wavelengths, which is not true of most dielectric UV mirrors
  • UV fluorescence excitation paths: near-ultraviolet excitation lines are routed with reflectance above 90% and without the angular sensitivity of an interference coating
  • UV curing and mask alignment: a near-ultraviolet curing source is folded into a small exposure head where a half-inch optic and its holder are the only size that fits
  • UV-VIS spectrophotometer folding: one mirror covers the deuterium lamp range and the visible range, so the reference and sample arms do not need different coatings
  • Laser-induced fluorescence and Raman with UV excitation: the low scatter of a 40-20 polish keeps stray light out of a weak emission channel

Selection Guide

Three questions decide this part: the band, the aperture and the mount. The table below covers the coatings available on the half-inch substrate, and the paragraph after it covers the aperture choice against the 7.0 mm version of the same film.

Coating Band Average reflectance Part number When to choose it
UV-enhanced aluminum 250 nm – 450 nm Above 90% PF05-03-F01 (this page) Any beam below 450 nm, folded with a metal film
Protected aluminum 450 nm – 2 µm / 2 – 20 µm Above 90% / above 95% PF05-03-G01 Visible to infrared general folding, broadband default
Protected silver 450 nm – 2 µm / 2 – 20 µm Above 97% / above 95% PF05-03-P01 Highest visible and near-infrared reflectance
Protected gold 800 nm – 20 µm Above 96% PF05-03-M01 Infrared only, tarnish resistant
Uncoated blank Not applicable None specified PF05-03 When you will deposit your own coating

On aperture, the same film is available as the Ø7.0 mm PF03-03-F01. Choose the 7.0 mm part when the beam is narrow and the assembly is compact, since it sits in the MK7 and LMR7 mounts and keeps the footprint small. Choose this 12.7 mm part when the beam fills more of the aperture, when the layout already uses half-inch holders, or when the beam has to be steered without clipping at the edge. Because clear aperture is 90% of the diameter in both cases, the larger substrate gives a clear aperture close to twice that of the 7 mm item, which is the reason to move up.

FAQ

How does this differ from the Ø7.0 mm PF03-03-F01? Only in diameter and thickness. The coating, the 250 to 450 nm band, the above 90% average reflectance, the damage thresholds and the non-cleanable handling are the same; the substrate goes from 7.0 mm x 2.0 mm to 12.7 mm x 6.0 mm, which changes the clear aperture and the mount class.

Why is the specification only above 90% when a dielectric UV mirror quotes a higher figure? Because a metal film is broadband and angle-tolerant, and a dielectric stack is neither. The 90% is an average across the whole 250 to 450 nm band at any incidence angle up to 45 degrees; a dielectric mirror reaches a higher number over a much narrower band and at a specified angle, and shifts when the angle changes. For multi-line or variable-angle UV paths the metal film is the more predictable part.

Can the coating be cleaned? No. The aluminum film is soft and the overcoat is thin. Blow off dust with clean dry nitrogen or filtered air, keep fingers off the face, and replace the optic if contamination cannot be blown away. Solvent and tissue will remove the coating along with the contamination.

What are the damage thresholds at 266 nm and 355 nm? 0.25 J/cm² at 266 nm with 10 ns pulses at 10 Hz over a Ø0.150 mm spot, and 0.3 J/cm² at 355 nm with the same pulse length and repetition rate over a Ø0.381 mm spot. Continuous ratings are 300 W/cm at 1.064 µm and 500 W/cm at 10.6 µm. Compare your energy density at the mirror, not at the laser output.

Does it work at 45 degrees of incidence? Yes. Metallic coatings are relatively insensitive to angle of incidence, so the same part serves a 45 degree fold, a periscope and a near-normal return. The one coating in this range with an angle restriction is ultrafast-enhanced silver, which is specified for 45 degrees; this aluminum coating is not.

Disclaimer

Specifications on this page are compiled from Thorlabs official published material and are provided as a selection reference only. The current official specification sheet governs; specifications and appearance may change without notice. Commercial terms and lead time are quoted by our sales team on request. Reproduction of this page without written permission is not permitted.

Contact Us

Changsha Soar Laser Equipment Co., Ltd. supplies genuine Thorlabs optics to laboratories and machine builders. For coating selection, aperture sizing, mount matching or lead time on a specific part number, contact us: hotline +86 159 2722 0467, email 859818709@qq.com, or use the enquiry form on www.soar-laser.cn. Tell us the wavelength, the beam diameter at the mirror and the pulse energy or continuous power, and we will confirm whether this coating is the right one before you order.

Reviews

There are no reviews yet.

Be the first to review “Thorlabs PF05-03-F01 Ø1/2″ UV-Enhanced Aluminum Mirror, 250-450 nm”

Your email address will not be published. Required fields are marked *

中文EN